8 resultados para Density Measurements

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

67P/Churyumov-Gerasimenko (67P) is a Jupiter-family comet and the object of investigation of the European Space Agency mission Rosetta. This report presents the first full 3D simulation results of 67P’s neutral gas coma. In this study we include results from a direct simulation Monte Carlo method, a hydrodynamic code, and a purely geometric calculation which computes the total illuminated surface area on the nucleus. All models include the triangulated 3D shape model of 67P as well as realistic illumination and shadowing conditions. The basic concept is the assumption that these illumination conditions on the nucleus are the main driver for the gas activity of the comet. As a consequence, the total production rate of 67P varies as a function of solar insolation. The best agreement between the model and the data is achieved when gas fluxes on the night side are in the range of 7% to 10% of the maximum flux, accounting for contributions from the most volatile components. To validate the output of our numerical simulations we compare the results of all three models to in situ gas number density measurements from the ROSINA COPS instrument. We are able to reproduce the overall features of these local neutral number density measurements of ROSINA COPS for the time period between early August 2014 and January 1 2015 with all three models. Some details in the measurements are not reproduced and warrant further investigation and refinement of the models. However, the overall assumption that illumination conditions on the nucleus are at least an important driver of the gas activity is validated by the models. According to our simulation results we find the total production rate of 67P to be constant between August and November 2014 with a value of about 1 × 10²⁶ molecules s⁻¹.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tree rings dominate millennium-long temperature reconstructions and many records originate from Scandinavia, an area for which the relative roles of external forcing and internal variation on climatic changes are, however, not yet fully understood. Here we compile 1,179 series of maximum latewood density measurements from 25 conifer sites in northern Scandinavia, establish a suite of 36 subset chronologies, and analyse their climate signal. A new reconstruction for the 1483–2006 period correlates at 0.80 with June–August temperatures back to 1860. Summer cooling during the early 17th century and peak warming in the 1930s translate into a decadal amplitude of 2.9°C, which agrees with existing Scandinavian tree-ring proxies. Climate model simulations reveal similar amounts of mid to low frequency variability, suggesting that internal ocean-atmosphere feedbacks likely influenced Scandinavian temperatures more than external forcing. Projected 21st century warming under the SRES A2 scenario would, however, exceed the reconstructed temperature envelope of the past 1,500 years.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osteoporosis is characterised by a progressive loss of bone mass and microarchitecture which leads to increased fracture risk. Some of the drugs available to date have shown reductions in vertebral and non-vertebral fracture risk. However, in the ageing population of industrialised countries, still more fractures happen today than are avoided, which highlights the large medical need for new treatment options, models, and strategies. Recent insights into bone biology, have led to a better understanding of bone cell functions and crosstalk between osteoblasts, osteoclasts, and osteocytes at the molecular level. In the future, the armamentarium against osteoporotic fractures will likely be enriched by (1.) new bone anabolic substances such as antibodies directed against the endogenous inhibitors of bone formation sclerostin and dickkopf-1, PTH and PTHrp analogues, and possibly calcilytics; (2.) new inhibitors of bone resorption such as cathepsin K inhibitors which may suppress osteoclast function without impairing osteoclast viability and thus maintain bone formation by preserving the osteoclast-osteoblast crosstalk, and denosumab, an already widely available antibody against RANKL which inhibits osteoclast formation, function, and survival; and (3.) new therapeutic strategies based on an extended understanding of the pathophysiology of osteoporosis which may include sequential therapies with two or more bone active substances aimed at optimising the management of bone capital acquired during adolescence and maintained during adulthood in terms of both quantity and quality. Finally, one of the future challenges will be to identify those patients and patient populations expected to benefit the most from a given drug therapy or regimen. The WHO fracture risk assessment tool FRAX® and improved access to bone mineral density measurements by DXA will play a key role in this regard.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To study the effects of a milking system that partially compensates for milk flow-dependent vacuum loss compared with a standard (high-line) milking unit in a tie-stall barn, milk flow and vacuum patterns were recorded in 10 cows during machine milking with 2 milking systems in a crossover design for 7 d each. Before and after each treatment period postmilking teat condition was recorded by ultrasound cross-sectioning. Additionally, 2 methods to measure teat tissue condition were compared: longitudinal teat ultrasound cross-sectioning and teat tissue density measurements with the spring-loaded caliper (cutimeter method). The partial compensation of milk flow-dependent vacuum loss caused an elevation of the peak flow rate (4.74+/-0.08 vs. 4.29+/-0.07 kg/min) and a shorter duration of plateau (1.57+/-0.06 vs. 1.96+/-0.07 min) compared with the standard milking system. Total milk yield, duration of incline and decline of milk flow, average milk flow, time until peak flow rate, main milking time, and total milking time did not differ between treatments (overall means: 13.75+/-0.17 kg; 0.65+/-0.01 min; 2.88+/-0.09 min; 2.82+/-0.05 kg/min; 1.65+/-0.03 min; 5.23+/-0.09 min, and 5.30+/-0.10 min, respectively). The vacuum drop in the short milk tube during periods of high milk flow was less in the compensating vacuum than in the standard milking system (11+/-1.1 vs. 15+/-0.7 kPa). Teat measures as determined by ultrasound remained unchanged over the entire experimental period with both milking systems. Postmilking teat tissue measures including their recovery within 20 min after the end of milking show a correlation (0.85 and 0.71, respectively) between the methods used (ultrasound and cutimeter method). In conclusion, a more constant vacuum at the teat tip (within the short milk tube) during periods of high milk flow affected milk flow patterns, mainly increasing peak flow rate. However, the reduced vacuum loss did not increase the overall speed of milking. In addition, effects of higher vacuum stability on teat condition and udder health were not obvious.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Airway mucus accumulation is associated with indoor irritant and allergen exposure in horses with recurrent airway obstruction (RAO). Epidermal growth factor receptor (EGFR) and a chloride channel (calcium activated, family member 1; CLCA1) are key signalling molecules involved in mucin gene expression. OBJECTIVES: We hypothesised that exposure to irritants and aeroallergens would lead to increased expression of the mucin gene eqMUC5AC and increased stored mucosubstance in the airways of RAO-affected horses, associated with increased neutrophils and CLCA1 and EGFR mRNA levels. METHODS: We performed quantitative RT-PCR of eqMUC5AC, CLCA1 and EGFR; volume density measurements of intraepithelial mucosubstances; and cytological differentiation of intraluminal inflammatory cells in small cartilaginous airways from cranial left and right and caudal left and right lung lobes of 5 clinically healthy and 5 RAO-affected horses that had been exposed to indoor stable environment for 5 days before euthanasia. RESULTS: Neutrophils were increased in RAO-affected horses compared to clinically healthy controls. EqMUC5AC mRNA levels were positively correlated with both CLCA1 and EGFR mRNA levels in RAO-affected horses but only with CLCA1 in controls. The relationship between eqMUC5AC and CLCA1 differed in the 2 groups of horses with RAO-affected animals overexpressing CLCA1 in relation to eqMUC5AC. CONCLUSIONS: These data implicate CLCA1 as a signalling molecule in the expression of eqMUC5AC in horses but also suggest differential regulation by CLCA1 and EGFR between horses with RAO and those with milder degrees of airway inflammation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite the fact that bone mineral density (BMD) is an important fracture risk predictor in human medicine, studies in equine orthopedic research are still lacking. We hypothesized that BMD correlates with bone failure and fatigue fractures of this bone. Thus, the objectives of this study were to measure the structural and mechanical properties of the proximal phalanx with dual energy X-ray absorptiometry (DXA), to correlate the data obtained from DXA and computer tomography (CT) measurements to those obtained by loading pressure examination and to establish representative region of interest (ROI) for in vitro BMD measurements of the equine proximal phalanx for predicting bone failure force. DXA was used to measure the whole bone BMD and additional three ROI sites in 14 equine proximal phalanges. Following evaluation of the bone density, whole bone, cortical width and area in the mid-diaphyseal plane were measured on CT images. Bones were broken using a manually controlled universal bone crusher to measure bone failure force and reevaluated for the site of fractures on follow-up CT images. Compressive load was applied at a constant displacement rate of 2 mm/min until failure, defined as the first clear drop in the load measurement. The lowest BMD was measured at the trabecular region (mean +/- SD: 1.52 +/- 0.12 g/cm2; median: 1.48 g/cm2; range: 1.38-1.83 g/cm2). There was a significant positive linear correlation between trabelcular BMD and the breaking strength (P = 0.023, r = 0.62). The trabecular region of the proximal phalanx appears to be the only significant indicator of failure of strength in vitro. This finding should be reassessed to further reveal the prognostic value of trabecular BMD in an in vivo fracture risk model.