90 resultados para De Pasquale
em BORIS: Bern Open Repository and Information System - Berna - Suiça
The use of flat panel angioCT (DynaCT) for navigation through a deformed and fractured carotid stent
Resumo:
Navigation through a previously deployed and deformed stent is a difficult interventional task. Inadvertent navigation through the struts of a stent can potentially lead to incomplete secondary stent extension and vessel occlusion. Better visualisation of the pathway through the stent can reduce the risks of the procedural complications and reduce the reluctance of the interventionalist to navigate through a previously deployed stent. We describe a technique of visualisation of the pathway navigated by a guidewire through a previously deployed deformed and fractured carotid stent by the use of DynaCT. Three-dimensional reconstruction of the stent/microwire allows excellent visualisation of the correct pathway of the microwire within the stent.
Resumo:
Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far has a different design and mechanical properties in terms of thrombus-device interaction. Therefore, a systematic evaluation under standardized conditions in vivo of these new devices is needed. The purpose of this study was to evaluate the efficiency, thrombus-device interaction, and potential complications of the novel Phenox CRC for distal mechanical thrombectomy in vivo. The device was evaluated in an established animal model in the swine. Recanalization rate, thromboembolic events, vasospasm, and complications were assessed. Radiopaque thrombi (2 cm length) were used for the visualization of thrombus-device interaction during retrieval. The Phenox CRC (4 mm diameter) was assessed in 15 vessel occlusions. For every occlusion a maximum of 3 retrieval attempts were performed. Complete recanalization (TICI 3/TIMI 3) was achieved in 86.7% of vessel occlusions. In 66.7% (10/15), the first retrieval attempt was successful, and in 20% (3/15), the second attempt led to complete recanalization of the parent artery. In 2 cases (13.3%) thrombus retrieval was not successful (TICI 0/TIMI 0). In 1 case (6.7%) a minor embolic event occurred in a small side branch. No distal thromboembolic event was observed during the study. Thrombus-device interaction illustrated the entrapment of the thrombus by the microfilaments and the proximal cage of the device. No significant thrombus compression was observed. No vessel perforation, dissection, or fracture of the device occurred. In this small animal study, the Phenox CRC was a safe and effective device for mechanical thrombectomy. The unique design with a combination of microfilaments and proximal cage reduces thrombus compression with a consequently high recanalization and low complication rate.
Resumo:
The optimal management of patients with symptomatic severe ostial vertebral artery stenosis (OVAS) is currently unclear. We analyzed the long-term outcome of consecutive patients with OVAS who received either medical treatment (MT) or vertebral artery stenting (VAS).
Resumo:
Assessments of spinal nociceptive withdrawal reflexes can be used in human research both to evaluate the effect of analgesics and explore pain mechanisms related to sensitization. Before the reflex can be used as a clinical tool, normative values need to be determined in large scale studies. The aim of this study was to determine the reference values of spinal nociceptive reflexes and subjective pain thresholds (to single and repeated stimulation), and of the area of the reflex receptive fields (RRF) in 300 pain-free volunteers. The influences of gender, age, height, weight, body-mass index (BMI), body side of testing, depression, anxiety, catastrophizing and parameters of Short-Form 36 (SF-36) were analyzed by multiple regressions. The 95% confidence intervals were determined for all the tests as normative values. Age had a statistically and quantitatively significant impact on the subjective pain threshold to single stimuli. The reflex threshold to single stimulus was lower on the dominant compared to the non-dominant side. Depression had a negative impact on the subjective pain threshold to single stimuli. All the other analyses either did not reveal statistical significance or displayed quantitatively insignificant correlations. In conclusion, normative values of parameters related to the spinal nociceptive reflex were determined. This allows their clinical application for assessing central hyperexcitability in individual patients. The parameters investigated explore different aspects of sensitization processes that are largely independent of demographic characteristics, cognitive and affective factors.
Resumo:
The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization.
Resumo:
To report the use of the second-generation Amplatzer Vascular Plug II (AVP II) for the treatment of a posttraumatic type A carotid-cavernous fistula (CCF).
Resumo:
Delayed occlusion time in parent artery occlusion of brain-supplying vessels might carry risk for thromboembolic complications. Vascular plug devices are successfully used in cardiopulmonary and peripheral interventions to occlude high-flow lesions and have been adapted for use in neurointerventions. The purpose of the present study was to experimentally evaluate the immediate occlusion time of the AMPLATZER vascular plug (AVP) II-a second-generation cylindrical, self-expandable, resheathable nitinol wire mesh consisting of three lobes-in the carotid artery.
Resumo:
Quantitative sensory tests are widely used in human research to evaluate the effect of analgesics and explore altered pain mechanisms, such as central sensitization. In order to apply these tests in clinical practice, knowledge of reference values is essential. The aim of this study was to determine the reference values of pain thresholds for mechanical and thermal stimuli, as well as withdrawal time for the cold pressor test in 300 pain-free subjects. Pain detection and pain tolerance thresholds to pressure, heat and cold were determined at three body sites: (1) lower back, (2) suprascapular region and (3) second toe (for pressure) or the lateral aspect of the leg (for heat and cold). The influences of gender, age, height, weight, body-mass index (BMI), body side of testing, depression, anxiety, catastrophizing and parameters of Short-Form 36 (SF-36) were analyzed by multiple regressions. Quantile regressions were performed to define the 5th, 10th and 25th percentiles as reference values for pain hypersensitivity and the 75th, 90th and 95th percentiles as reference values for pain hyposensitivity. Gender, age and/or the interaction of age with gender were the only variables that consistently affected the pain measures. Women were more pain sensitive than men. However, the influence of gender decreased with increasing age. In conclusion, normative values of parameters related to pressure, heat and cold pain stimuli were determined. Reference values have to be stratified by body region, gender and age. The determination of these reference values will now allow the clinical application of the tests for detecting abnormal pain reactions in individual patients.
Resumo:
Preoperative mapping of the arterial spinal supply prior to thoracoabdominal aortic aneurysm repair is highly relevant because of high risk for postoperative ischemic spinal cord injuries such as paraparesis or paraplegia.
Resumo:
Intra-arterial thrombolysis can be used for treatment of basilar artery occlusion. Predictors of outcome before initiation of treatment are of special interest.
Resumo:
Susceptibility-weighted MR imaging (SWI) is usually obtained without administration of intravenous gadolinium (Gd). However, it is occasionally necessary to perform SWI after Gd is injected. The effects of Gd on SWI have not been systematically examined. The aim of this prospective study was to investigate whether performing SWI after Gd would influence the diagnostic image quality, parenchymal signal and vascular enhancement. An additional aim is to suggest potential future applications for Gd-enhanced SWI.
Resumo:
Experimental tissue fusion benefits from the selective heating of superparamagnetic iron oxide nanoparticles (SPIONs) under high frequency irradiation. However, the metabolic pathways of SPIONs for tissue fusion remain unknown. Hence, the goal of this in vivo study was to analyze the distribution of SPIONs in different organs by means of magnetic resonance imaging (MRI) and histological analysis after a SPION-containing patch implantation.