30 resultados para DSA,problemi matematici,didattica personalizzata e individualizzata,consegne modificate
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To prospectively compare the diagnostic accuracy of steady-state, high-spatial-resolution magnetic resonance (MR) angiography of the lower leg, performed with a blood pool contrast agent, with selective digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial disease.
Resumo:
PURPOSE: To compare diagnostic accuracy of multi-station, high-spatial resolution contrast-enhanced MR angiography (CE-MRA) of the lower extremities with digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Of 485 consecutive patients undergoing a run-off CE-MRA, 152 patients (86 male, 66 female; mean age, 71.6 years) with suspected peripheral arterial occlusive disease were included into our Institutional Review Board approved study. All patients underwent MRA and DSA of the lower extremities within 30 days. MRA was performed at 1.5 Tesla with a single bolus of 0.1 mmol/kg body weight of gadobutrol administered at a rate of 2.0 mL/s at three stations. Two readers evaluated the MRA images independently for stenosis grade and image quality. Sensitivity and specificity were derived. RESULTS: Sensitivity and specificity ranged from 73% to 93% and 64% to 89% and were highest in the thigh area. Both readers showed comparable results. Evaluation of good and better quality MRAs resulted in a considerable improvement in diagnostic accuracy. CONCLUSION: Contrast-enhanced MRA demonstrates good sensitivity and specificity in the investigation of the vasculature of the lower extremities. While a minor investigator experience dependence remains, it is standardizable and shows good inter-observer agreement. Our results confirm that the administration of Gadobutrol at a standard dose of 0.1 mmol/kg for contrast-enhanced runoff MRA is able to detect hemodynamically relevant stenoses. Use of contrast-enhanced MRA as an alternative to intra-arterial DSA in the evaluation and therapeutic planning of patients with suspected peripheral arterial occlusive disease is well justified. J. Magn. Reson. Imaging 2013;37:1427-1435. © 2012 Wiley Periodicals, Inc.
Resumo:
BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.
Resumo:
BACKGROUND: Systematic need for angiography in diagnosis of carotid artery stenosis and indication of surgical therapy is still debated. Noninvasive imaging techniques such as MR angiography (MRA) or CT angiography (CTA) offer an alternative to digital subtraction angiography (DSA) and are increasingly used in clinical practice. In this study, we present the radiological characteristics and clinical results of a series of patients operated on the basis of combined ultrasonography (US)/MRA. METHODS: This observational study included all the patients consecutively operated for a carotid stenosis in our Department from October 1998 to December 2004. The applied MRA protocol had previously been established in a large correlation study with DSA. DSA was used only in case of discordance between US and MRA. The preoperative radiological information furnished by MRA was compared with intraoperative findings. The outcome of the operation was assessed according to ECST criteria. RESULTS: Among 327 patients, preoperative MRA was performed in 278 (85%), DSA in 44 (13.5%) and CT angiography in 5 (1.5%). Most of DSA studies were performed as emergency for preparation of endovascular therapy or for reasons other than carotid stenosis. Eleven additional DSA (3.3%) complemented US/MRA, mostly because diverging diagnosis of subocclusion of ICA. No direct morbidity or intraoperative difficulty was related to preoperative MRA. Combined mortality/major morbidity rate was 0.9% (3 patients) and minor morbidity rate 5.5% (18 patients). CONCLUSIONS: This observational study describes a well-established practice of carotid surgery and supports the exclusive use of non invasive diagnostic imaging for indicating and deciding the operation.