29 resultados para DISTAL INTERPHALANGEAL JOINT

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To analyze functional and subjective outcomes of patients with posttraumatic dorsal instability of the distal radioulnar joint (DRUJ) treated by a dorsal capsular imbrication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nail is the largest skin appendage. It grows continuously through life in a non-cyclical manner; its growth is not hormone-dependent. The nail of the middle finger of the dominant hand grows fastest with approximately 0.1 mm/day, whereas the big toe nail grows only 0.03-0.05 mm/d. The nails' size and shape vary characteristically from finger to finger and from toe to toe, for which the size and shape of the bone of the terminal phalanx is responsible. The nail apparatus consists of both epithelial and connective tissue components. The matrix epithelium is responsible for the production of the nail plate whereas the nail bed epithelium mediates firm attachment. The hyponychium is a specialized structure sealing the subungual space and allowing the nail plate to physiologically detach from the nail bed. The proximal nail fold covers most of the matrix. Its free end forms the cuticle which seals the nail pocket or cul-de-sac. The dermis of the matrix and nail bed is specialized with a morphogenetic potency. The proximal and lateral nail folds form a frame on three sides giving the nail stability and allowing it to grow out. The nail protects the distal phalanx, is an extremely versatile tool for defense and dexterity and increases the sensitivity of the tip of the finger. Nail apparatus, finger tip, tendons and ligaments of the distal interphalangeal joint form a functional unit and cannot be seen independently. The nail organ has only a certain number of reaction patterns that differ in many respects from hairy and palmoplantar skin.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Despite improved medical treatment of rheumatoid arthritis, carpal tunnel compression, caput ulnae syndrome and palmar and dorsal tenosynovitis with potential tendon rupture represent urgent surgical indications. While diagnostic and therapeutic synovectomy may guide medical treatment, it should be performed before joint instability and destructive arthritis are established. Swan-neck and Boutonniere deformities as well as ulnar or radial drift of metacarpophalangeal (MCP) joints or the wrist can only be corrected when the involved joints are supple and intact. In the presence of destructive arthritis, partial and total wrist fusion, arthroplasties of the MCP joints and arthrodeses of the distal interphalangeal joints are recommended.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An acute injury to the triangular fibrocartilage complex (TFCC) with avulsion of the foveal attachment can produce distal radioulnar joint (DRUJ) instability. The avulsed TFCC is translated distally so the footprint will be bathed in synovial fluid from the DRUJ and will become covered in synovitis. If the TFCC fails to heal to the footprint, then persistent instability can occur. The authors describe a surgical technique indicated for the treatment of persistent instability of the DRUJ due to foveal detachment of the TFCC. The procedure utilizes a loop of palmaris longus tendon graft passed through the ulnar aspect of the TFCC and into an osseous tunnel in the distal ulna to reconstruct the foveal attachment. This technique provides stability of the distal ulna to the radius and carpus. We recommend this procedure for chronic instability of the DRUJ due to TFCC avulsion, but recommend that suture repair remain the treatment of choice for acute instability. An arthroscopic assessment includes the trampoline test, hook test, and reverse hook test. DRUJ ballottement under arthroscopic vision details the direction of instability, the functional tear pattern, and unmasks concealed tears. If the reverse hook test demonstrates a functional instability between the TFCC and the radius, then a foveal reconstruction is contraindicated, and a reconstruction that stabilizes the radial and ulnar aspects of the TFCC is required. The foveal reconstruction technique has the advantage of providing a robust anatomically based reconstruction of the TFCC to the fovea, which stabilizes the DRUJ and the ulnocarpal sag.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective In the pediatric population traumatic injuries of the upper extremity are common. After therapy a decision has to be made if the mobility of the joint lies within a normal range. The purpose of this study was to give an introduction to normative data. We investigate if there is a significant difference in the range of motion (ROM) between male and female probands and furthermore, if an effect of the age can be detected. Methods We performed an institutional review board-approved study of healthy girls and boys aged between 2 and 16 years without any medical history of an upper extremity fracture. We investigated the active ROM of the elbow, wrist, metacarpophalangeal, and interphalangeal joints. Furthermore, age, handedness, weight, and height were recorded. A total of 171 adolescents with a mean age of 10.6 years were included and separated into four cohorts by age: 2 to 5, 6 to 10, 11 to 13, and 14 to 16 years. Results We found significant differences between the genders in the age group from 11 to 13 years for the flexion of the elbow, the pronation, the flexion of the interphalangeal joint of the thumb, as well as the flexion of the metacarpophalangeal joints of digitus II to V. Furthermore, a significant difference in the same joints except from the elbow flexion could be demonstrated between the genders. Conclusion Our study contributes normative data for upper extremity ROM in the pediatric population and presents a gender-related difference in certain joints. Clinical Relevance Normative data for the ROM of upper extremity joints in children is helpful for the evaluation of pediatric orthopedic patients and provides the framework for therapeutic resolution. Since a great number of traumatic injuries in children affect the upper extremity, this information may help the physician to estimate the impact of the injury and decide on the therapeutic management.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background A triangular fibrocartilage complex (TFCC) injury can produce distal radioulnar joint (DRUJ) instability. If the foveal attachment is avulsed, it translates distally. The footprint is separated from its origin and will become covered in synovitis, preventing healing. The authors describe a surgical technique for the treatment of instability of the DRUJ due to chronic foveal detachment of the TFCC. Technique The procedure utilizes a loop of autologous palmaris longus tendon graft passed through the ulnar aspect of the TFCC and through an osseous tunnel in the distal ulna to reconstruct the fovel attachment. Patients and Methods We report on nine patients with a mean age of 42. Median follow-up was 13 months. Results The median pain scores measured were reduced from 8 to 3 postoperatively, and all had a stable DRUJ. Conclusions This technique provides stability of the distal ulna to the radius and carpus, with potential for biologic healing through osseous integration. It is a robust, anatomically based reconstruction of the TFCC to the fovea that stabilizes the DRUJ and the ulnar-carpal sag.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the reliability and validity of a novel ultrasound (US) imaging method to measure metacarpophalangeal (MCP) and proximal interphalangeal (PIP) finger joint cartilage. METHODS: We examined 48 patients with rheumatoid arthritis (RA), 18 patients with osteoarthritis (OA), 24 patients with unclassified arthritis of the finger joints, and 34 healthy volunteers. The proximal cartilage layer of MCP and PIP joints for fingers 2-5 was bilaterally visualized from a posterior view, with joints in approximately 90 degrees flexion. Cartilage thickness was measured with integrated tools on static images. External validity was assessed by measuring radiologic joint space width (JSW) and a numeric joint space narrowing (JSN) score in patients with RA. RESULTS: Precise measurement was possible for 97.5% of MCP and 94.2% of PIP joints. Intraclass correlation coefficients for bilateral total joint US scores were 0.844 (95% confidence interval [95% CI] 0.648-0.935) for interobserver comparisons and 0.928 (95% CI 0.826-0.971) for intraobserver comparisons (using different US devices). The US score correlated with JSN for both hands (adjusted R(2) = 0.513, P < 0.001) and JSW of the same finger joints (adjusted R(2) = 0.635, P < 0.001). Reduced cartilage shown by US allowed discrimination of early symptomatic OA versus early RA and healthy joints. In patients with RA, US scores correlated with duration of treatment-resistant, progressive RA. CONCLUSION: The US method of direct visualization and quantification of cartilage in MCP and PIP joints is objective, reliable, valid, and can be useful for diagnostic purposes in patients with arthritis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the effect of age and disease on mineral distribution at the distal third of the tibia, bone mineral content (BMC) and bone mineral density (BMD) were measured at lumbar spine (spine), femoral neck (neck), and diaphysis (Dia) and distal epiphysis (Epi) of the tibia in 89 healthy control women of different age groups (20-29, n = 12; 30-39, n = 11; 40-44, n = 12; 45-49, n = 12; 50-54, n = 12; 55-59, n = 10; 60-69, n = 11; 70-79, n = 9), in 25 women with untreated vertebral osteoporosis (VOP), and in 19 women with primary hyperparathyroidism (PHPT) using dual-energy x-ray absorptiometry (DXA; Hologic QDR 1000 and standard spine software). A soft tissue simulator was used to compensate for heterogeneity of soft tissue thickness around the leg. Tibia was scanned over a length of 130 mm from the ankle joint, fibula being excluded from analysis. For BMC and BMD, 10 sections 13 mm each were analyzed separately and then pooled to define the epiphysis (Epi 13-52 mm) and diaphysis area (Dia 91-130 mm). Precision after repositioning was 1.9 and 2.1% for Epi and Dia, respectively. In the control group, at any site there was no significant difference between age groups 20-29 and 30-39, which thus were pooled to define the peak bone mass (PBM).(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Understanding the anatomy of the ligaments of the distal radius aids in the surgical repair of ligamentous injuries and the prediction of intraarticular fracture patterns. Purposes (1) to measure the horizontal and vertical distances of the origins of the radiocarpal ligaments from the most ulnar corner of the sigmoid notch and the joint line, respectively; and (2) to express them as a percentile of the total width of the bony distal radius. Methods We dissected 8 cadaveric specimens and identified the dorsal radiocarpal, radioscaphocapitate, and the long and short radiolunate ligaments. Results The dorsal radiocarpal ligament attached from the 16th to the 52nd percentile of the radial width. The radioscaphocapitate ligament attached around the radial styloid from the 86th percentile volarly to the 87th percentile dorsally. The long radiolunate ligament attached from the 59th to the 85th percentile, and the short radiolunate ligament attached from the 14th to the 41st percentile. Discussion There was a positive correlation between the radial width and the horizontal distance of the ligaments from the sigmoid notch. These findings may aid individualized surgical repair or reconstruction adjusted to patient size and enable further standardized research on distal radial fractures and their relationship with radiocarpal ligaments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to describe the arthroscopic anatomy of the bovine fetlock joint using one palmar/plantar and three dorsal joint approaches. A comparative anatomic, ultrasonographic and arthroscopic study using 20 cadaveric feet from 13 non-lame adult dairy cows was performed. Arthroscopy was accomplished using a rigid arthroscope to view the synovial cavities with their synovial villi and parts of the following structures: the distal ends of the metacarpal/metatarsal III/IV bones with their trochleae and sagittal ridges, synovial grooves, the articular surfaces of the proximal sesamoid bones, the proximal aspects of the first phalanges, the lateral and medial collateral ligaments, the suspensory ligament and the interdigital ligaments as parts of the interosseus muscle, the cruciate sesamoidean ligaments, the communication site between the lateral and medial pouch in the palmar/plantar area, and dorsally the septum between the lateral and the medial pouch. The technique allowed a good overall view of most relevant structures in the sound cadaver joint. Further investigations are warranted to evaluate the diagnostic, therapeutic and prognostic applications of these techniques in the treatment of septic arthritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The purpose of this study was to assess the impact of renal insufficiency (RI) on the distribution pattern of peripheral arterial disease (PAD). We hypothesised that RI is associated with a distally accentuated involvement of the peripheral arterial tree. Design This is a retrospective analysis. Materials and Methods Analysis was based on a consecutive series of 2709 patients with chronic PAD of atherosclerotic origin undergoing primary endovascular treatment of lower-extremity arteries. Atherosclerotic pattern was grouped into femoropopliteal (n = 2085) and infragenicular (n = 892) disease according to target lesions treated while using iliac disease (n = 1133) as reference. Univariable and multivariable multinomial regression analyses were performed to assess relation with RI. Results are shown as relative risk ratio (RRRs) with 95% confidence intervals (95% CIs). A p < 0.05 was considered statistically significant. RI was defined as glomerular filtration rate (GFR) < 60 ml min−1 1.73 m−2. Results Presence of RI was an independent risk factor for a centrifugal lesion pattern (RRR 1.48, 95% CI: 1.17–1.86, p = 0.001). Moreover, a decrease in GFR by 10 ml min−1 1.73 m−2 was associated with an RRR of 1.08 for below-the-knee arterial disease (95% CI: 1.03–1.13, p = 0.003). Conclusion Presence and severity of RI are independent predictors of a distal obstructive pattern in patients with symptomatic PAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mechanical pain sensitivity is assessed in every patient with pain, either by palpation or by quantitative pressure algometry. Despite widespread use, no studies have formally addressed the usefulness of this practice for the identification of the source of pain. We tested the hypothesis that assessing mechanical pain sensitivity distinguishes damaged from healthy cervical zygapophysial (facet) joints. METHODS: Thirty-three patients with chronic unilateral neck pain were studied. Pressure pain thresholds (PPTs) were assessed bilaterally at all cervical zygapophysial joints. The diagnosis of zygapophysial joint pain was made by selective nerve blocks. Primary analysis was the comparison of the PPT between symptomatic and contralateral asymptomatic joints. The secondary end points were as follows: differences in PPT between affected and asymptomatic joints of the same side of patients with zygapophysial joint pain; differences in PPT at the painful side between patients with and without zygapophysial joint pain; and sensitivity and specificity of PPT for 2 different cutoffs (difference in PPT between affected and contralateral side by 1 and 30 kPa, meaning that the test was considered positive if the difference in PPT between painful and contralateral side was negative by at least 1 and 30 kPa, respectively). The PPT of patients was also compared with the PPT of 12 pain-free subjects. RESULTS: Zygapophysial joint pain was present in 14 patients. In these cases, the difference in mean PPT between affected and contralateral side (primary analysis) was −6.2 kPa (95% confidence interval: −19.5 to 7.2, P = 0.34). In addition, the secondary analyses yielded no statistically significant differences. For the cutoff of 1 kPa, sensitivity and specificity of PPT were 67% and 16%, respectively, resulting in a positive likelihood ratio of 0.79 and a diagnostic confidence of 38%. When the cutoff of 30 kPa was considered, the sensitivity decreased to only 13%, whereas the specificity increased to 95%, resulting in a positive likelihood ratio of 2.53 and a diagnostic confidence of 67%. The PPT was significantly lower in patients than in pain-free subjects (P < 0.001). CONCLUSIONS: Assessing mechanical pain sensitivity is not diagnostic for cervical zygapophysial joint pain. The finding should stimulate further research into a diagnostic tool that is widely used in the clinical examination of patients with pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoarticular allograft is one possible treatment in wide surgical resections with large defects. Performing best osteoarticular allograft selection is of great relevance for optimal exploitation of the bone databank, good surgery outcome and patient’s recovery. Current approaches are, however, very time consuming hindering these points in practice. We present a validation study of a software able to perform automatic bone measurements used to automatically assess the distal femur sizes across a databank. 170 distal femur surfaces were reconstructed from CT data and measured manually using a size measure protocol taking into account the transepicondyler distance (A), anterior-posterior distance in medial condyle (B) and anterior-posterior distance in lateral condyle (C). Intra- and inter-observer studies were conducted and regarded as ground truth measurements. Manual and automatic measures were compared. For the automatic measurements, the correlation coefficients between observer one and automatic method, were of 0.99 for A measure and 0.96 for B and C measures. The average time needed to perform the measurements was of 16 h for both manual measurements, and of 3 min for the automatic method. Results demonstrate the high reliability and, most importantly, high repeatability of the proposed approach, and considerable speed-up on the planning.