21 resultados para DEHISCENCE

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postoperative fascial dehiscence and open abdomen are severe postoperative complications and are associated with surgical site infections, fistula, and hernia formation at long-term follow-up. This study was designed to investigate whether intraperitoneal implantation of a composite prosthetic mesh is feasible and safe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the healing outcome of soft tissue dehiscence coverage at implant sites. MATERIAL AND METHODS: Ten patients with one mucosal recession defect at an implant site and a contralateral unrestored clinical crown without recession were recruited. The soft tissue recessions were surgically covered using a coronally advanced flap in combination with a free connective tissue graft. Healing was studied at 1, 3 and 6 months post-operatively. RESULTS: Soft tissue dehiscences were covered with a coronal overcompensation of the flap margin up to 1.2 mm after the procedure. After 1 month, the coverage shrank to a mean of 75%, after 3 months to 70% and after 6 months to 66%. CONCLUSIONS: The implant sites revealed a substantial, clinically significant improvement following coronal mucosal displacement in combination with connective tissue grafting, but in none of the sites, a could complete implant soft tissue dehiscence coverage be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical plugging and resurfacing are well established treatments of superior semicircular canal dehiscence, while capping with hydroxyapatite cement has been little discussed in literature. The aim of this study was to prove the efficacy of the capping technique. Charts of patients diagnosed with superior semicircular canal dehiscence were reviewed retrospectively. All patients answered the dizziness handicap inventory, a survey analyzing the impact of their symptoms on their quality of life. Capping of the dehiscent canal was performed via the middle fossa approach in all cases. Ten out of 22 patients diagnosed with superior semicircular canal dehiscence were treated with surgical capping, nine of which were included in this study. No major perioperative complications occurred. In 8 out of 9 (89 %) patients, capping led to a satisfying reduction of the main symptoms. One patient underwent revision surgery 1 year after the initial intervention. Scores in the dizziness handicap inventory were lower in the surgically treated group than in the non-surgically treated group, but results were not statistically significant (P = 0.45). Overall, capping is a safe and efficient alternative to plugging and resurfacing of superior semicircular canal dehiscence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: To identify the rates and reasons for plate removal (PR) among patients treated for facial fractures. MATERIALS AND METHODS: A retrospective review of files of 238 patients. RESULTS: Forty-eight patients (20.2%) had plates removed. The reason for removal was objective in 33.3% and subjective in 29.2%. The most common subjective reason was cold sensitivity, and the most common objective reason was wound dehiscence/infection. Women had PR for subjective reasons more often than men (p=0.018). Removal was performed more often for subjective reasons after zygomatico-orbital fractures than after mandibular fractures (p=0.002). Plates inserted in the mandible from an intraoral approach were removed more frequently than extraorally inserted mandibular plates, intraorally inserted maxillary plates, and extraorally inserted plates in other locations (p<0.001). Orbital rim plates had a higher risk of being removed than maxillary or frontal bone plates (p=0.02). CONCLUSIONS: Subjective discomfort is a notable reason for PR among Finnish patients, suggesting that the cold climate has an influence on the need for removal. Patients receiving mandibular osteosynthesis with miniplates from an intraoral approach are at risk of hardware removal because of wound dehiscence/infection and loose/broken hardware, reminding us that more rigid fixation devices should not be forgotten despite the widespread use of miniplates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this practical manual is to describe and illustrate each step of the basic surgical procedures involved in the placement of implants in qualified patients. To that end, each procedure is briefly but lucidly described; carefully illustrated in a series of drawings of the techniques and instrumentation used; and reinforced through clinical photographs, including radiographic and postoperative follow-up views. In addition to the basic implant surgical principles, evidence-based indications and procedures for guided bone regeneration in apical fenestration and crestal dehiscence defects, and for simultaneous sinus floor elevation via the lateral window and osteotome techniques are featured.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this follow-up study was to evaluate the clinical usefulness of a new type of 3-dimensional (3D) miniplate for open reduction and monocortical fixation of mandibular angle fractures. PATIENTS AND METHODS: In 20 consecutive patients, noncomminuted mandibular angle fractures were treated with open reduction and fixation using a 2 mm 3D miniplate system in a transoral approach. All patients were systematically monitored until 6 months postoperatively. Among the outcome parameters recorded were infection, hardware failure, wound dehiscence, and sensory disturbance of the inferior alveolar nerve. RESULTS: The mean operation time from incision to wound closure was 65 minutes. Two patients had a mucosal wound dehiscence with no consequences. None developed an infection requiring a plate removal. All but 2 patients had normal sensory function 3 months after surgery. Plate fracture occurred in one patient in whom a preceding surgical removal of the third molar had been the reason for the mandibular fracture. In the absence of clinical symptoms, the patient declined plate removal. On final follow-up, fracture healing was considered clinically complete in all patients. CONCLUSIONS: The 3D plating system described here is suitable for fixation of simple mandibular angle fractures and is an easy-to-use alternative to conventional miniplates. The system may be contraindicated in patients in whom insufficient interfragmentary bone contact causes minor stability of the fracture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Low tissue oxygen tension is an important factor leading to the development of wound dehiscence and anastomotic leakage after colon surgery. We tested whether supplemental fluid and supplemental oxygen can increase tissue oxygen tension in healthy and injured, perianastomotic, and anastomotic colon in an acutely instrumented pig model of anastomosis surgery. METHODS: Sixteen Swiss Landrace pigs were anesthetized (isoflurane 0.8%-1%) and their lungs ventilated. The animals were randomly assigned to low fluid treatment ("low" group, 3 mL x kg(-1) x h(-1) lactated Ringer's solution) or high fluid treatment ("high" group, 10 mL/kg bolus, 18 mL x kg(-1) x h(-1) lactated Ringer's solution) during colon anastomosis surgery and a subsequent measurement period (4 h). Two-and-half hours after surgery, tissue oxygen tension was recorded for 30 min during ventilation with 30% oxygen. Three hours after surgery, the animals' lungs were ventilated with 100% oxygen for 60 min. Tissue oxygen tension was recorded in the last 30 min. Tissue oxygen tension was measured with polarographic Clark-type electrodes, positioned in healthy colonic wall, close (2 cm) to the anastomosis, and in the anastomosis. RESULTS: In every group, tissue oxygen tension during ventilation with 100% oxygen was approximately twice as high as during ventilation with 30% oxygen, a statistically significant result. High or low volume crystalloid fluid treatment had no effect on colon tissue oxygen tension. CONCLUSIONS: Supplemental oxygen, but not supplemental crystalloid fluid, increased tissue oxygen tension in healthy, perianastomotic, and anastomotic colon tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p < 0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Complications and failures after microvascular free tissue transfer for lower extremity reconstruction have a negative impact on postoperative course and final outcome. Therefore, a 10-year analysis on lower extremity reconstruction with free flaps was performed with a special emphasis on patient co-morbidities such as cardiovascular diseases, diabetes mellitus, body mass index and history of smoking, in order to identify potential risk factors. Complications such as haematoma, seroma, infection, wound dehiscence, as well as partial flap loss, postoperative thrombosis of the anastomosis and eventual total flap loss were gathered from the medical records. Limb salvage was 100%, however 40% suffered from complications ranging from minor wound dehiscence to total flap loss. None of the above-mentioned potential risk factors was associated with an increased rate of complications. However, in flaps that required revision for thrombosis, the age of the patients was significantly higher in the group of flaps that eventually failed when compared to flaps that were salvaged. In conclusion, lower extremity reconstruction with microvascular free tissue transfer is a safe and reliable procedure with a high success rate, however partial flap loss remains an important issue. Increased age was the only factor identified with an increased risk for subsequent flap loss in cases that were revised for thrombosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This study presents an evaluation of the preoperative and postoperative best corrected visual acuity (BCVA), as well as of the incidence of perioperative and postoperative complications after opacified hydrogel intraocular lens (IOL) exchange. PATIENTS AND METHODS: We exchanged opacified hydrogel IOLs (Hydroview H 60 M, Bausch ; Lomb) in 55 patients (55 eyes). Preoperative and postoperative BCVA were compared. Intraoperative and postoperative complications were recorded. Follow-up period ranged from 3 months to 24 months. RESULTS: Mean BCVA improved significantly from 0.05 preoperatively to 0.4 at 3 months postoperatively and to 0.2 at the end of the follow-up period. Forty patients (72.7 %) reported visual improvement. The procedure was uneventful in 30 eyes (54.5 %) with complete removal of the opacified IOL optics and haptics. Intraoperative complications included partial zonular dehiscence in 10 eyes (18.2 %), en block capsular bag-IOL extraction in 2 eyes (3.6 %), posterior capsule rupture in 2 eyes (3.6 %), hyphema in 3 eyes (5.5 %), retained haptics in 8 eyes (14.5 %). Postoperative complications included corneal decompensation in 5 eyes (9.1 %), cystoid macular edema in 15 eyes (27.3 %), elevated intraocular pressure in 6 eyes (10.9 %), and retinal detachment in 1 eye (1.8 %). CONCLUSIONS: Visual acuity improved after opacified hydrogel IOL exchange, however, coexistent ocular morbidity as well as the appearance of serious postoperative complications may not yield the expected results. For these reasons extensive informed consent is mandatory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Regular preoperative application of corticosteroids has been considered as a contraindication to lung transplantation for fear of an increased risk of postoperative morbidity and mortality. Recently, however, we have accepted patients for transplantation in whom treatment with steroid medication could not be terminated preoperatively. Up to February 1991, 27 unilateral and bilateral transplantations in 26 patients were analyzed. Corticosteroid therapy was discontinued at least three months prior to transplantation in 13 patients (group 1), whereas in 14 cases, the patients continued their daily corticosteroid therapy to the time of transplantation (prednisolone, 0.1 to 0.3 mg/kg/day; group 2). There were no significant differences between the groups with respect to sex, age, diagnosis, or type of transplantation. One limited bronchial dehiscence occurred; the incidence of postoperative bronchial stenosis was identical in both cohorts; one patient died in each group. In conclusion, no increased morbidity or mortality could be found following lung transplantation with regular preoperative administration of prednisolone up to 0.3 mg/kg/day. Thus, patients who cannot be weaned from their steroid medication but who otherwise are acceptable candidates should not be excluded from lung transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim was (1) to evaluate the soft-tissue reaction of a synthetic polyethylene glycol (PEG) hydrogel used as a barrier membrane for guided bone regeneration (GBR) compared with a collagen membrane and (2) to test whether or not the application of this in situ formed membrane will result in a similar amount of bone regeneration as the use of a collagen membrane. MATERIAL AND METHODS: Tooth extraction and preparation of osseous defects were performed in the mandibles of 11 beagle dogs. After 3 months, 44 cylindrical implants were placed within healed dehiscence-type bone defects resulting in approximately 6 mm exposed implant surface. The following four treatment modalities were randomly allocated: PEG+autogenous bone chips, PEG+hydroxyapatite (HA)/tricalcium phosphate (TCP) granules, bioresorbable collagen membrane+autogenous bone chips and autogenous bone chips without a membrane. After 2 and 6 months, six and five dogs were sacrificed, respectively. A semi-quantitative evaluation of the local tolerance and a histomorphometric analysis were performed. For statistical analysis, repeated measures analysis of variance (ANOVA) and subsequent pairwise Student's t-test were applied (P<0.05). RESULTS: No local adverse effects in association with the PEG compared with the collagen membrane was observed clinically and histologically at any time-point. Healing was uneventful and all implants were histologically integrated. Four out of 22 PEG membrane sites revealed a soft-tissue dehiscence after 1-2 weeks that subsequently healed uneventful. Histomorphometric measurement of the vertical bone gain showed after 2 months values between 31% and 45% and after 6 months between 31% and 38%. Bone-to-implant contact (BIC) within the former defect area was similarly high in all groups ranging from 71% to 82% after 2 months and 49% to 91% after 6 months. However, with regard to all evaluated parameters, the PEG and the collagen membranes did not show any statistically significant difference compared with sites treated with autogenous bone without a membrane. CONCLUSION: The in situ forming synthetic membrane made of PEG was safely used in the present study, revealing no biologically significant abnormal soft-tissue reaction and demonstrated similar amounts of newly formed bone for defects treated with the PEG membrane compared with defects treated with a standard collagen membrane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. MATERIAL AND METHODS: For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. RESULTS: All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. CONCLUSIONS: The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.