16 resultados para D-shape cladding

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present 3-D simulations of impacts into Asteroid 21 Lutetia, the subject of a fly-by by the European Space Agency's Rosetta mission to Comet 67P/Churyumov-Gerasimenko. Using a 3-D shape model of the asteroid, impacts of sizes sufficient to reproduce the observed craters in Lutetia's North Polar Crater Cluster (NPCC) as observed by the OSIRIS experiment have been simulated using the Smoothed Particle Hydrodynamics technique. The asteroid itself has been modelled both as a homogeneous body and as a body with an iron core.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An Internet portal accessible at www.gdb.unibe.ch has been set up to automatically generate color-coded similarity maps of the ChEMBL database in relation to up to two sets of active compounds taken from the enhanced Directory of Useful Decoys (eDUD), a random set of molecules, or up to two sets of user-defined reference molecules. These maps visualize the relationships between the selected compounds and ChEMBL in six different high dimensional chemical spaces, namely MQN (42-D molecular quantum numbers), SMIfp (34-D SMILES fingerprint), APfp (20-D shape fingerprint), Xfp (55-D pharmacophore fingerprint), Sfp (1024-bit substructure fingerprint), and ECfp4 (1024-bit extended connectivity fingerprint). The maps are supplied in form of Java based desktop applications called “similarity mapplets” allowing interactive content browsing and linked to a “Multifingerprint Browser for ChEMBL” (also accessible directly at www.gdb.unibe.ch) to perform nearest neighbor searches. One can obtain six similarity mapplets of ChEMBL relative to random reference compounds, 606 similarity mapplets relative to single eDUD active sets, 30 300 similarity mapplets relative to pairs of eDUD active sets, and any number of similarity mapplets relative to user-defined reference sets to help visualize the structural diversity of compound series in drug optimization projects and their relationship to other known bioactive compounds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statistical shape models (SSMs) have been used widely as a basis for segmenting and interpreting complex anatomical structures. The robustness of these models are sensitive to the registration procedures, i.e., establishment of a dense correspondence across a training data set. In this work, two SSMs based on the same training data set of scoliotic vertebrae, and registration procedures were compared. The first model was constructed based on the original binary masks without applying any image pre- and post-processing, and the second was obtained by means of a feature preserving smoothing method applied to the original training data set, followed by a standard rasterization algorithm. The accuracies of the correspondences were assessed quantitatively by means of the maximum of the mean minimum distance (MMMD) and Hausdorf distance (H(D)). Anatomical validity of the models were quantified by means of three different criteria, i.e., compactness, specificity, and model generalization ability. The objective of this study was to compare quasi-identical models based on standard metrics. Preliminary results suggest that the MMMD distance and eigenvalues are not sensitive metrics for evaluating the performance and robustness of SSMs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to validate the accuracy and reproducibility of a statistical shape model-based 2D/3D reconstruction method for determining cup orientation after total hip arthroplasty. With a statistical shape model, this method allows reconstructing a patient-specific 3D-model of the pelvis from a standard AP X-ray radiograph. Cup orientation (inclination and anteversion) is then calculated with respect to the anterior pelvic plane that is derived from the reconstructed model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The measurement of charged-particle event shape variables is presented in inclusive inelastic pp collisions at a center-of-mass energy of 7 TeV using the ATLAS detector at the LHC. The observables studied are the transverse thrust, thrust minor, and transverse sphericity, each defined using the final-state charged particles' momentum components perpendicular to the beam direction. Events with at least six charged particles are selected by a minimum-bias trigger. In addition to the differential distributions, the evolution of each event shape variable as a function of the leading charged-particle transverse momentum, charged-particle multiplicity, and summed transverse momentum is presented. Predictions from several Monte Carlo models show significant deviations from data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bone scrapers are commonly used to harvest autologous bone in oral and implant surgery. The angle of the cutting blade is a variable that distinguishes bone scrapers. In the present study, the impact of the angle of the cutting blade on the in vitro characteristics of harvested bone was determined. Bone scrapers with blade angles of 15°, 25°, 35°, 45°, and 55° were used to harvest porcine cortical mandibular bone. The number and characteristics of the cells that grew out from the bone chips were examined. The data showed that, independent of the angle of the cutting blade, viable cells were barely detectable in fresh bone grafts. However, cells with a fibroblastic morphology appeared within 1 week in the culture dishes. After 21 days, the number of cells did not differ significantly between the five preparations. Moreover, cells responded to incubation with bone morphogenetic protein 7 (BMP-7) with an increased alkaline phosphatase activity, irrespective of the preparation. The data suggest that bone scrapers with different cutting angles produce bone chips with comparable in vitro characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Acetabular rim trimming is indicated in pincer hips with an oversized lunate surface but could result in a critically decreased size of the lunate surface in pincer hips with acetabular malorientation. There is a lack of detailed three-dimensional anatomy of lunate surface in pincer hips. Therefore, we questioned how does (1) size and (2) shape of the lunate surface differ among hips with different types of pincer impingement? METHOD We retrospectively compared size and shape of the lunate surface between acetabular retroversion (48 hips), deep acetabulum (34 hips), protrusio acetabuli (seven hips), normal acetabuli (30 hips), and hip dysplasia (45 hips). Using magnetic resonance imaging (MRI) arthrography with radial slices we measured size in percentage of the femoral head coverage and shape using the outer (inner) center-edge angles and width of lunate surface. RESULTS Hips with retroversion had a decreased size and deep hips had normal size of the lunate surface. Both had a normal shape of the outer acetabular rim. Protrusio hips had an increased size and a prominent outer acetabular rim. In all three types of pincer hips the acetabular fossa was increased. CONCLUSION Size and shape of the lunate surface differs substantially among different types of pincer impingement. In contrast to hips with protrusio acetabuli, retroverted and deep hips do not have an increased size of the lunate surface. Acetabular rim trimming in retroverted and deep hips should be performed with caution. Based on our results, acetabular reorientation would theoretically be the treatment of choice in retroverted hips.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, reconstruction of three-dimensional (3D) patient-specific models of a hip joint from two-dimensional (2D) calibrated X-ray images is addressed. Existing 2D-3D reconstruction techniques usually reconstruct a patient-specific model of a single anatomical structure without considering the relationship to its neighboring structures. Thus, when those techniques would be applied to reconstruction of patient-specific models of a hip joint, the reconstructed models may penetrate each other due to narrowness of the hip joint space and hence do not represent a true hip joint of the patient. To address this problem we propose a novel 2D-3D reconstruction framework using an articulated statistical shape model (aSSM). Different from previous work on constructing an aSSM, where the joint posture is modeled as articulation in a training set via statistical analysis, here it is modeled as a parametrized rotation of the femur around the joint center. The exact rotation of the hip joint as well as the patient-specific models of the joint structures, i.e., the proximal femur and the pelvis, are then estimated by optimally fitting the aSSM to a limited number of calibrated X-ray images. Taking models segmented from CT data as the ground truth, we conducted validation experiments on both plastic and cadaveric bones. Qualitatively, the experimental results demonstrated that the proposed 2D-3D reconstruction framework preserved the hip joint structure and no model penetration was found. Quantitatively, average reconstruction errors of 1.9 mm and 1.1 mm were found for the pelvis and the proximal femur, respectively.