12 resultados para Current limiting ratio

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The "Trond" protocol of nerve excitability tests has been used widely to assess axonal function in peripheral nerve. In this study, the routine Trond protocol was expanded to refine assessment of cAMP-dependent, hyperpolarization-activated current (I(h)) activity. I(h) activity is generated by hyperpolarization-activated, cyclic nucleotide-modulated (HCN) channels in response to hyperpolarization. It limits activity-dependent hyperpolarization, contributes to neuronal automaticity, and is implicated in chronic pain states. Published data regarding I(h) activity in motor nerve are scant. We used additional strong, prolonged hyperpolarizing conditioning stimuli in the threshold electrotonus component of the Trond protocol to demonstrate the time-course of activation of I(h) in motor axons. Fifteen healthy volunteers were tested on four occasions during 1 week. I(h) action was revealed in the threshold electrotonus by the limiting and often reversal, after about 100 ms, of the threshold increase caused by strong hyperpolarizing currents. Statistical analysis by repeated-measures analysis of variance enabled confidence limits to be established for variation between subjects and within subjects. The results demonstrate that, of all the excitability parameters, those dependent on I(h) were the most characteristic of an individual, because variance between subjects was more than four times the variance within subjects. This study demonstrates a reliable method for in vivo assessment of I(h,) and also serves to document the normal variability in nerve excitability properties within subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Recently recommended treatment modalities for prosthetic joint infection (PJI) were evaluated. METHODS: A retrospective cohort analysis of 68 patients with PJI of hip or knee who were treated from 1995 through 2004 was conducted at the University Hospital Bern (Bern, Switzerland). RESULTS: A 2-stage exchange was the most frequent (75.0%) surgical strategy, followed by retention and debridement (17.6%), 1-stage exchange (5.9%), and resection arthroplasty or suppressive antimicrobial treatment (1.5%). The chosen strategy was in 88% agreement with the recommendations. Adherence was only 17% for retention and debridement and was 0% for 1-stage exchange. Most PJIs (84%) were treated with an adequate or partially adequate antimicrobial regimen. Recurrence-free survival was observed in 51.5% of PJI episodes after 24 months of follow-up. The risk of treatment failure was significantly higher for PJI treated with a surgical strategy other than that recommended (hazard ratio, 2.34; 95% confidence interval, 1.10-4.70; P = .01) and for PJIs treated with antibiotics not corresponding to recommendations (hazard ratio, 3.45; confidence interval, 1.50-7.60; P = .002). Other risk factors associated with lack of healing were a high infection score at the time of diagnosis (hazard ratio, 1.29; 95% confidence interval, 1.10-1.40; P < .001) and presence of a sinus tract (hazard ratio, 2.35; 95% confidence interval, 1.10-5.0; P = .02). CONCLUSIONS: Our study demonstrates the value of current treatment recommendations. Inappropriate choice of conservative surgical strategies (such as debridement and retention) and inadequate antibiotic treatment are associated with failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate, for the depiction of simulated hypervascular liver lesions in a phantom, the effect of a low tube voltage, high tube current computed tomographic (CT) technique on image noise, contrast-to-noise ratio (CNR), lesion conspicuity, and radiation dose. MATERIALS AND METHODS: A custom liver phantom containing 16 cylindric cavities (four cavities each of 3, 5, 8, and 15 mm in diameter) filled with various iodinated solutions to simulate hypervascular liver lesions was scanned with a 64-section multi-detector row CT scanner at 140, 120, 100, and 80 kVp, with corresponding tube current-time product settings at 225, 275, 420, and 675 mAs, respectively. The CNRs for six simulated lesions filled with different iodinated solutions were calculated. A figure of merit (FOM) for each lesion was computed as the ratio of CNR2 to effective dose (ED). Three radiologists independently graded the conspicuity of 16 simulated lesions. An anthropomorphic phantom was scanned to evaluate the ED. Statistical analysis included one-way analysis of variance. RESULTS: Image noise increased by 45% with the 80-kVp protocol compared with the 140-kVp protocol (P < .001). However, the lowest ED and the highest CNR were achieved with the 80-kVp protocol. The FOM results indicated that at a constant ED, a reduction of tube voltage from 140 to 120, 100, and 80 kVp increased the CNR by factors of at least 1.6, 2.4, and 3.6, respectively (P < .001). At a constant CNR, corresponding reductions in ED were by a factor of 2.5, 5.5, and 12.7, respectively (P < .001). The highest lesion conspicuity was achieved with the 80-kVp protocol. CONCLUSION: The CNR of simulated hypervascular liver lesions can be substantially increased and the radiation dose reduced by using an 80-kVp, high tube current CT technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: New treatment modalities have become increasingly popular for the treatment of acute thrombotic thrombocytopenic purpura. Widespread availability of ADAMTS13 assays resulted in the increased recognition of patients with hereditary thrombotic thrombocytopenic purpura and specific issues related to acquired ADAMTS13 deficiency. These new aspects with implications on management of thrombotic thrombocytopenic purpura patients are reviewed here. RECENT FINDINGS: Today, plasma exchange with the replacement of fresh frozen plasma is still the treatment of choice in acute thrombotic thrombocytopenic purpura. The finding of circulating anti-ADAMTS13 autoantibodies in the majority of patients constitutes the rationale for the concomitant administration of immunosuppressive drugs. Rituximab seems to have a favorable benefit-risk ratio in plasma-refractory and relapsing thrombotic thrombocytopenic purpura; however, long-term follow-up data are not yet available. Constitutively lacking ADAMTS13 in hereditary thrombotic thrombocytopenic purpura can be supplemented by simple plasma infusions. Severe acquired ADAMTS13 deficiency either at presentation or in remission identifies patients at a particularly high risk of relapse. SUMMARY: Despite progress in understanding the pathophysiology of thrombotic thrombocytopenic purpura, acute bouts as well as relapses still represent serious health threats to patients and rapid initiation of plasma exchange is mandatory. Large randomized clinical trials, however, need to determine whether new treatment modalities are superior to standard plasma exchange.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of the study was to investigate the influence of continued injecting drug use, enrolment in an opiate substitution treatment programme (OSTP), or cessation of injecting drug use on the uptake and course of antiretroviral therapy (ART). Design A prospective observational study of all participants in the Swiss HIV Cohort Study followed between 1997 and 2006 was carried out. METHODS: We distinguished four groups of former or current injecting drug users (IDUs): (i) abstinent former IDUs; (ii) persons in OSTPs without concomitant injecting drug use; (iii) persons in OSTPs with concomitant injecting drug use; (vi) current IDUs. These groups were compared with a group of patients who had never been IDUs. Factors related to ART uptake and virological endpoints were analysed using logistic generalized estimating equations. RESULTS: We followed 8660 participants for 48 477 person-years; 29.7% were in the IDU HIV transmission group. The likelihood of being on ART at biannual visits was lower among individuals in OSTPs with concomitant injecting drug use [odds ratio (OR) 0.79; 95% confidence interval (CI) 0.71-0.89] and current IDUs (OR 0.80; 95% CI 0.67-0.96), compared with those who had never been IDUs (reference), abstinent former IDUs (OR 1.13; 95% CI 1.02-1.25) and individuals in OSTPs without injecting drug use (OR 1.18; 95% CI 1.06-1.31). The likelihood of suppressed viral replication on ART was similar among those who had never been IDUs, abstinent former IDUs and individuals in an OSTP without injecting drug use, and lower among those in OSTPs with concomitant drug use (OR 0.82; 95% CI 0.72-0.93) and current IDUs (OR 0.81; 0.65-1.00). Adherence to ART was decreased among persons with continued injecting drug use, and correlated with virological outcome. CONCLUSIONS: Uptake of and virological response to ART were improved among abstinent former IDUs and persons in OSTPs without concomitant injecting drug use, compared with persons with continued injecting drug use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: This collaboration of seven observational clinical cohorts investigated risk factors for treatment-limiting toxicities in both antiretroviral-naive and experienced patients starting nevirapine-based combination antiretroviral therapy (NVPc). METHODS: Patients starting NVPc after 1 January 1998 were included. CD4 cell count at starting NVPc was classified as high (>400/microl/>250/microl for men/women, respectively) or low. Cox models were used to investigate risk factors for discontinuations due to hypersensitivity reactions (HSR, n = 6547) and discontinuation of NVPc due to treatment-limiting toxicities and/or patient/physician choice (TOXPC, n = 10,186). Patients were classified according to prior antiretroviral treatment experience and CD4 cell count/viral load at start NVPc. Models were stratified by cohort and adjusted for age, sex, nadir CD4 cell count, calendar year of starting NVPc and mode of transmission. RESULTS: Median time from starting NVPc to TOXPC and HSR were 162 days [interquartile range (IQR) 31-737] and 30 days (IQR 17-60), respectively. In adjusted Cox analyses, compared to naive patients with a low CD4 cell count, treatment-experienced patients with high CD4 cell count and viral load more than 400 had a significantly increased risk for HSR [hazard ratio 1.45, confidence interval (CI) 1.03-2.03] and TOXPC within 18 weeks (hazard ratio 1.34, CI 1.08-1.67). In contrast, treatment-experienced patients with high CD4 cell count and viral load less than 400 had no increased risk for HSR 1.10 (0.82-1.46) or TOXPC within 18 weeks (hazard ratio 0.94, CI 0.78-1.13). CONCLUSION: Our results suggest it may be relatively well tolerated to initiate NVPc in antiretroviral-experienced patients with high CD4 cell counts provided there is no detectable viremia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Few studies consider the incidence of individual AIDS-defining illnesses (ADIs) at higher CD4 counts, relevant on a population level for monitoring and resource allocation. Methods. Individuals from the Collaboration of Observational HIV Epidemiological Research Europe (COHERE) aged ≥14 years with ≥1 CD4 count of ≥200 µL between 1998 and 2010 were included. Incidence rates (per 1000 person-years of follow-up [PYFU]) were calculated for each ADI within different CD4 strata; Poisson regression, using generalized estimating equations and robust standard errors, was used to model rates of ADIs with current CD4 ≥500/µL. Results. A total of 12 135 ADIs occurred at a CD4 count of ≥200 cells/µL among 207 539 persons with 1 154 803 PYFU. Incidence rates declined from 20.5 per 1000 PYFU (95% confidence interval [CI], 20.0–21.1 per 1000 PYFU) with current CD4 200–349 cells/µL to 4.1 per 1000 PYFU (95% CI, 3.6–4.6 per 1000 PYFU) with current CD4 ≥ 1000 cells/µL. Persons with a current CD4 of 500–749 cells/µL had a significantly higher rate of ADIs (adjusted incidence rate ratio [aIRR], 1.20; 95% CI, 1.10–1.32), whereas those with a current CD4 of ≥1000 cells/µL had a similar rate (aIRR, 0.92; 95% CI, .79–1.07), compared to a current CD4 of 750–999 cells/µL. Results were consistent in persons with high or low viral load. Findings were stronger for malignant ADIs (aIRR, 1.52; 95% CI, 1.25–1.86) than for nonmalignant ADIs (aIRR, 1.12; 95% CI, 1.01–1.25), comparing persons with a current CD4 of 500–749 cells/µL to 750–999 cells/µL. Discussion. The incidence of ADIs was higher in individuals with a current CD4 count of 500–749 cells/µL compared to those with a CD4 count of 750–999 cells/µL, but did not decrease further at higher CD4 counts. Results were similar in patients virologically suppressed on combination antiretroviral therapy, suggesting that immune reconstitution is not complete until the CD4 increases to >750 cells/µL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Neuropsychological deficits (NPD) are common in patients with aneurysmal subarachnoid haemorrhage (aSAH). NPD are one of the major limiting factors for patients with an otherwise acceptable prognosis for sustained quality of life. There are only a few studies reporting outcome after aSAH, which used a standardized neuropsychological test battery as a primary or secondary outcome measure. Aim of this study was to determine the current practice of reporting NPD following aSAH in clinical studies. METHODS A MEDLINE analysis was performed using the search term "subarachnoid haemorrhage outcome". The latest 1,000 articles were screened. We recorded study design, number of patients, and the presence of neuropsychological outcome report. Additionally, the time of testing after aSAH, the neuropsychological tests administered, as well as the percentage of patients with NPD were analyzed. RESULTS A total of 324 publications between 2009 and 2012 were selected for further review. Of those, 21 studies (6.5%) reported neuropsychological outcome, in 2,001 of 346,666 patients (0.6%). The assessment of NPD differed broadly using both subjective and objective cognitive evaluation, and a large variety of tests were used. CONCLUSION Neuropsychological outcome is underreported, and there is great variety in assessment in currently published clinical articles on aSAH. Prospective randomized trials treating aSAH may benefit from implementing more comprehensive and standardized neuropsychological outcome measures. This approach might identify otherwise unnoticed treatment effects in future interventional studies of aSAH patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stable carbon isotope analysis of methane (delta C-13 of CH4) on atmospheric samples is one key method to constrain the current and past atmospheric CH4 budget. A frequently applied measurement technique is gas chromatography (GC) isotope ratio mass spectrometry (IRMS) coupled to a combustion-preconcentration unit. This report shows that the atmospheric trace gas krypton (Kr) can severely interfere during the mass spectrometric measurement, leading to significant biases in delta C-13 of CH4, if krypton is not sufficiently separated during the analysis. According to our experiments, the krypton interference is likely composed of two individual effects, with the lateral tailing of the doubly charged Kr-86 peak affecting the neighbouring m/z 44 and partially the m/z 45 Faraday cups. Additionally, a broad signal affecting m/z 45 and especially m/z 46 is assumed to result from scattered ions of singly charged krypton. The introduced bias in the measured isotope ratios is dependent on the chromatographic separation, the krypton-to-CH4 mixing ratio in the sample, the focusing of the mass spectrometer as well as the detector configuration and can amount to up to several per mil in delta C-13. Apart from technical solutions to avoid this interference, we present correction routines to a posteriori remove the bias.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a measurement of the charged current interaction rate of the electron neutrino beam component of the beam above 1.5 GeV using the large fiducial mass of the T2K π0 detector. The predominant portion of the νe flux (∼85%) at these energies comes from kaon decays. The measured ratio of the observed beam interaction rate to the predicted rate in the detector with water targets filled is 0.89 ± 0.08 (stat.) ± 0.11 (sys.), and with the water targets emptied is 0.90 ± 0.09 (stat.) ± 0.13 (sys.). The ratio obtained for the interactions on water only from an event subtraction method is 0.87 ± 0.33 (stat.) ± 0.21 (sys.). This is the first measurement of the interaction rate of electron neutrinos on water, which is particularly of interest to experiments with water Cherenkov detectors.