4 resultados para Current Pulse

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to characterize the nociceptive withdrawal reflex (NWR) and to define the nociceptive threshold in 25 healthy, non-medicated experimental sheep in standing posture. Electrical stimulation of the dorsal lateral digital nerves of the right thoracic and the pelvic limb was performed and surface-electromyography (EMG) from the deltoid (all animals) and the femoral biceps (18 animals) or the peroneus tertius muscles (7 animals) was recorded. The behavioural reaction following each stimulation was scored on a scale from 0 (no reaction) to 5 (strong whole body reaction). A train-of-five 1 ms constant-current pulse was used and current intensity was stepwise increased until NWR threshold intensity was reached. The NWR threshold intensity (It) was defined as the minimal stimulus intensity able to evoke a reflex with a minimal Root-Mean-Square amplitude (RMSA) of 20 μV, a minimal duration of 10 ms and a minimal reaction score of 1 (slight muscle contraction of the stimulated limb) within the time window of 20 to 130 ms post-stimulation. Based on this value, further stimulations were performed below (0.9It) and above threshold (1.5It and 2It). The stimulus-response curve was described. Data are reported as medians and interquartile ranges. At the deltoid muscle It was 4.4 mA (2.9–5.7) with an RMSA of 62 μV (30–102). At the biceps femoris muscle It was 7.0 mA (4.0–10.0) with an RMSA of 43 μV (34–50) and at the peroneus tertius muscle It was 3.4 mA (3.1–4.4) with an RMSA of 38 μV (32–46). Above threshold, RMSA was significantly increased at all muscles. Below threshold, RMSA was only significantly smaller than at It for the peroneus tertius muscle but not for the other muscles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trauma related haemorrhagic anaemia is rarely diagnosed by physical examination alone but typically includes measurement of blood haemoglobin, one of the most frequently ordered laboratory tests. Recently, noninvasive technologies have been developed that allow haemoglobin to be measured immediately without the need for intravenous access or having to take venous, arterial, or capillary blood. Moreover, with these technologies haemoglobin can be continuously measured in patients with active bleeding, to guide the start and stop of blood transfusions and to detect occult bleeding. Recent studies on the accuracy of the devices showed promising results in terms of accuracy of hemoglobin measurement compared to laboratory determination. The present review gives an overview on the technology itself and reviews the current literature on the subject.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY Multicentre Confidential Enquiries into Perioperative Equine Fatalities (CEPEF) have not been conducted since the initial CEPEF Phases 1-3, 20 years ago. OBJECTIVES To collect data on current practice in equine anaesthesia and to recruit participants for CEPEF-4. STUDY DESIGN Online questionnaire survey. METHODS An online questionnaire was prepared and the link distributed internationally to veterinarians possibly performing equine anaesthesia, using emails, posters, flyers and an editorial. The questionnaire included 52 closed, semiclosed and open questions divided into 8 subgroups: demographic data, anaesthetist, anaesthesia management (preoperative, technical equipment, monitoring, drugs, recovery), areas of improvements and risks and motivation for participation in CEPEF-4. Descriptive statistics and Chi-squared tests for comparison of categorical variables were performed. RESULTS A total of 199 questionnaires were completed by veterinarians from 14 different countries. Of the respondents, 43% worked in private hospitals, 36% in private practices and 21% in university teaching hospitals. In 40 institutions (23%) there was at least one diplomate of the European or American colleges of veterinary anaesthesia and analgesia on staff. Individual respondents reported routinely employ the following anaesthesia monitoring modalities: electrocardiography (80%), invasive arterial blood pressures (70%), pulse oximetry (60%), capnography (55%), arterial blood gases (47%), composition of inspired and expired gases (45%) and body temperature (35%). Drugs administered frequently or routinely as part of a standard protocol were: acepromazine (44%), xylazine (68%), butorphanol (59%), ketamine (96%), diazepam (83%), isoflurane (76%), dobutamine (46%), and, as a nonsteroidal anti-inflammatory drug, phenylbutazone (73%) or flunixin meglumine (66%). Recovery was routinely assisted by 40%. The main factors perceived by the respondents to affect outcome of equine anaesthesia were the preoperative health status of the animal and training of the anaesthetist. CONCLUSIONS Current practice in equine anaesthesia varies widely, and the study has highlighted important topics relevant for designing a future prospective multicentre cohort study (CEPEF-4). The Summary is available in Chinese - see Supporting information.