12 resultados para Cresap, Mark W.
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
In ischemic stroke, the site of arterial obstruction has been shown to influence recanalization and clinical outcomes. However, this has not been studied in randomized controlled trials, nor has the impact of arterial obstruction site on reperfusion and infarct growth been assessed. We studied the influence of site and degree of arterial obstruction patients enrolled in the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET).
Resumo:
the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET) was a prospective, randomized, double-blinded, placebo-controlled, phase II trial of alteplase between 3 and 6 hours after stroke onset. The primary outcome of infarct growth attenuation on MRI with alteplase in mismatch patients was negative when mismatch volumes were assessed volumetrically, without coregistration, which underestimates mismatch volumes. We hypothesized that assessing the extent of mismatch by coregistration of perfusion and diffusion MRI maps may more accurately allow the effects of alteplase vs placebo to be evaluated.
Resumo:
Here we present the Transcription Factor Encyclopedia (TFe), a new web-based compendium of mini review articles on transcription factors (TFs) that is founded on the principles of open access and collaboration. Our consortium of over 100 researchers has collectively contributed over 130 mini review articles on pertinent human, mouse and rat TFs. Notable features of the TFe website include a high-quality PDF generator and web API for programmatic data retrieval. TFe aims to rapidly educate scientists about the TFs they encounter through the delivery of succinct summaries written and vetted by experts in the field.
Resumo:
PURPOSE: To compare objective fellow and expert efficiency indices for an interventional radiology renal artery stenosis skill set with the use of a high-fidelity simulator. MATERIALS AND METHODS: The Mentice VIST simulator was used for three different renal artery stenosis simulations of varying difficulty, which were used to grade performance. Fellows' indices at three intervals throughout 1 year were compared to expert baseline performance. Seventy-four simulated procedures were performed, 63 of which were captured as audiovisual recordings. Three levels of fellow experience were analyzed: 1, 6, and 12 months of dedicated interventional radiology fellowship. The recordings were compiled on a computer workstation and analyzed. Distinct measurable events in the procedures were identified with task analysis, and data regarding efficiency were extracted. Total scores were calculated as the product of procedure time, fluoroscopy time, tools, and contrast agent volume. The lowest scores, which reflected efficient use of tools, radiation, and time, were considered to indicate proficiency. Subjective analysis of participants' procedural errors was not included in this analysis. RESULTS: Fellows' mean scores diminished from 1 month to 12 months (42,960 at 1 month, 18,726 at 6 months, and 9,636 at 12 months). The experts' mean score was 4,660. In addition, the range of variance in score diminished with increasing experience (from a range of 5,940-120,156 at 1 month to 2,436-85,272 at 6 months and 2,160-32,400 at 12 months). Expert scores ranged from 1,450 to 10,800. CONCLUSIONS: Objective efficiency indices for simulated procedures can demonstrate scores directly comparable to the level of clinical experience.
Resumo:
AIMS/HYPOTHESIS Plasminogen activator inhibitor-1 (PAI-1) has been regarded as the main antifibrinolytic protein in diabetes, but recent work indicates that complement C3 (C3), an inflammatory protein, directly compromises fibrinolysis in type 1 diabetes. The aim of the current project was to investigate associations between C3 and fibrinolysis in a large cohort of individuals with type 2 diabetes. METHODS Plasma levels of C3, C-reactive protein (CRP), PAI-1 and fibrinogen were analysed by ELISA in 837 patients enrolled in the Edinburgh Type 2 Diabetes Study. Fibrin clot lysis was analysed using a validated turbidimetric assay. RESULTS Clot lysis time correlated with C3 and PAI-1 plasma levels (r = 0.24, p < 0.001 and r = 0.22, p < 0.001, respectively). In a multivariable regression model involving age, sex, BMI, C3, PAI-1, CRP and fibrinogen, and using log-transformed data as appropriate, C3 was associated with clot lysis time (regression coefficient 0.227 [95% CI 0.161, 0.292], p < 0.001), as was PAI-1 (regression coefficient 0.033 [95% CI 0.020, 0.064], p < 0.05) but not fibrinogen (regression coefficient 0.003 [95% CI -0.046, 0.051], p = 0.92) or CRP (regression coefficient 0.024 [95% CI -0.008, 0.056], p = 0.14). No correlation was demonstrated between plasma levels of C3 and PAI-1 (r = -0.03, p = 0.44), consistent with previous observations that the two proteins affect different pathways in the fibrinolytic system. CONCLUSIONS/INTERPRETATION Similarly to PAI-1, C3 plasma levels are independently associated with fibrin clot lysis in individuals with type 2 diabetes. Therefore, future studies should analyse C3 plasma levels as a surrogate marker of fibrinolysis potential in this population.
Resumo:
BACKGROUND Meta-analyses of continuous outcomes typically provide enough information for decision-makers to evaluate the extent to which chance can explain apparent differences between interventions. The interpretation of the magnitude of these differences - from trivial to large - can, however, be challenging. We investigated clinicians' understanding and perceptions of usefulness of 6 statistical formats for presenting continuous outcomes from meta-analyses (standardized mean difference, minimal important difference units, mean difference in natural units, ratio of means, relative risk and risk difference). METHODS We invited 610 staff and trainees in internal medicine and family medicine programs in 8 countries to participate. Paper-based, self-administered questionnaires presented summary estimates of hypothetical interventions versus placebo for chronic pain. The estimates showed either a small or a large effect for each of the 6 statistical formats for presenting continuous outcomes. Questions addressed participants' understanding of the magnitude of treatment effects and their perception of the usefulness of the presentation format. We randomly assigned participants 1 of 4 versions of the questionnaire, each with a different effect size (large or small) and presentation order for the 6 formats (1 to 6, or 6 to 1). RESULTS Overall, 531 (87.0%) of the clinicians responded. Respondents best understood risk difference, followed by relative risk and ratio of means. Similarly, they perceived the dichotomous presentation of continuous outcomes (relative risk and risk difference) to be most useful. Presenting results as a standardized mean difference, the longest standing and most widely used approach, was poorly understood and perceived as least useful. INTERPRETATION None of the presentation formats were well understood or perceived as extremely useful. Clinicians best understood the dichotomous presentations of continuous outcomes and perceived them to be the most useful. Further initiatives to help clinicians better grasp the magnitude of the treatment effect are needed.
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
Drawing on the reception of Noh drama by Ezra Pound and William Butler Yeats, the article analyses both the literary and cultural ‘translations’ of this form of Japanese theatre in their works, focusing on Yeats’s play At the Hawk’s Well (1917). I conceptualize ‘cultural translation’ as the staging of relations that mark a residual cultural difference. Referred to as ‘foreignizing’ in translation theory, this method enables what Erika Fischer-Lichte has termed a ‘liminal experience’ for the audience –– an effect Yeats intended for the performance of his play. It evokes situations in which opposites collapse and new ways of acting or new combinations of symbols can be tried out. Yeats’s play will be used to sketch how an analysis of relations could serve as a general model for the study of cultural transfer as cultural translation in general. Keywords: cultural translation, translation theory, performance, William Butler Yeats, Itō Michio, Ezra Pound, At the Hawk’s Well