67 resultados para Coronary Circulation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
In vivo observations of microcirculatory behavior during autoregulation and adaptation to varying myocardial oxygen demand are scarce in the human coronary system. This study assessed microvascular reactions to controlled metabolic and pressure provocation [bicycle exercise and external counterpulsation (ECP)]. In 20 healthy subjects, quantitative myocardial contrast echocardiography and arterial applanation tonometry were performed during increasing ECP levels, as well as before and during bicycle exercise. Myocardial blood flow (MBF; ml·min(-1)·g(-1)), the relative blood volume (rBV; ml/ml), the coronary vascular resistance index (CVRI; dyn·s·cm(-5)/g), the pressure-work index (PWI), and the pressure-rate product (mmHg/min) were assessed. MBF remained unchanged during ECP (1.08 ± 0.44 at baseline to 0.92 ± 0.38 at high-level ECP). Bicycle exercise led to an increase in MBF from 1.03 ± 0.39 to 3.42 ± 1.11 (P < 0.001). The rBV remained unchanged during ECP, whereas it increased under exercise from 0.13 ± 0.033 to 0.22 ± 0.07 (P < 0.001). The CVRI showed a marked increase under ECP from 7.40 ± 3.38 to 11.05 ± 5.43 and significantly dropped under exercise from 7.40 ± 2.78 to 2.21 ± 0.87 (both P < 0.001). There was a significant correlation between PWI and MBF in the pooled exercise data (slope: +0.162). During ECP, the relationship remained similar (slope: +0.153). Whereas physical exercise decreases coronary vascular resistance and induces considerable functional capillary recruitment, diastolic pressure transients up to 140 mmHg trigger arteriolar vasoconstriction, keeping MBF and functional capillary density constant. Demand-supply matching was maintained over the entire ECP pressure range.
Resumo:
The coronary collateral circulation is an alternative source of blood supply to a myocardial area jeopardized by the failure of the stenotic or occluded vessel to provide enough blood flow to this region. Until recently, only qualitative or semiqualitative methods have been available for the assessment of the coronary collateral circulation in humans, such as the patient's history of walk-through angina pectoris, the registration of intracoronary ECG signs for myocardial ischaemia or angina pectoris during coronary occlusion, or coronary angiographic classification (score 0-3) of collaterals. Studies of coronary wedge pressure measurements distal of a balloon-occluded coronary artery and the recent advent of ultrathin pressure and Doppler angioplasty guidewires have made it possible to obtain pressure or flow velocity data in remote vascular areas and, thus, to calculate functional variables for coronary collateral flow. Those coronary occlusive pressure- and flow velocity-derived parameters express collateral flow as a fraction of antegrade coronary flow during vessel patency of the collateral-receiving vessel. They are both interchangeable, and they have been validated in comparison to 'traditional' methods and against each other. The possibility of accurately measuring coronary collateral flow indices in humans undergoing coronary balloon angioplasty opens areas of investigation of the pathogenesis, pathophysiology and therapeutic promotion of the collateral circulation previously reserved for exclusively experimental studies. The purpose of this article is to review several clinically available methods for the functional characterization of the coronary collateral circulation.
Resumo:
The functional relevance of coronary collaterals in humans has yet to be fully explored. Several studies demonstrated a protective role of collaterals in patients with coronary artery disease. On the other hand, negative aspects of well-developed coronary collaterals have been reported, e.g. a higher rate of restenosis following coronary angioplasty, or a redistribution of blood via collaterals away from the myocardial area in need towards normally perfused areas (coronary steal). In the past, the coronary collateral circulation has been assessed only qualitatively, using visual angiographic or nuclear imaging methods. With the recent advent of intracoronary Doppler and pressure-transducers, quantitative assessment of functional parameters of the coronary circulation has become feasible. This article reviews ongoing research in the field of coronary collaterals in humans, concerning their exact determination, the positive and negative aspects of their structure as well as their functional aspects.
Resumo:
Animal experiments have shown that the coronary circulation is pressure distensible, i.e., myocardial blood volume (MBV) increases with perfusion pressure. In humans, however, corresponding measurements are lacking so far. We sought to quantify parameters reflecting coronary distensibility such as MBV and coronary resistance (CR) during and after coronary angioplasty. Thirty patients with stable coronary artery disease underwent simultaneous coronary perfusion pressure assessment and myocardial contrast echocardiography (MCE) of 37 coronary arteries and their territories during and after angioplasty. MCE yielded MBV and myocardial blood flow (MBF; in ml · min(-1) · g(-1)). Complete data sets were obtained in 32 coronary arteries and their territories from 26 patients. During angioplasty, perfusion pressure, i.e., coronary occlusive pressure, and MBV varied between 9 and 57 mmHg (26.9 ± 11.9 mmHg) and between 1.2 and 14.5 ml/100 g (6.7 ± 3.7 ml/100 g), respectively. After successful angioplasty, perfusion pressure and MBV increased significantly (P < 0.001 for both) and varied between 64 and 118 mmHg (93.5 ± 12.8 mmHg) and between 3.7 and 17.3 ml/100 g (9.8 ± 3.4 ml/100 g), respectively. Mean MBF increased from 31 ± 20 ml · min(-1) · g(-1) during coronary occlusion, reflecting collateral flow, to 121 ± 33 ml · min(-1) · g(-1) (P < 0.01), whereas mean CR, i.e., the ratio of perfusion pressure and MBF, decreased by 20% (P < 0.001). In conclusion, the human coronary circulation is pressure distensible. MCE allows for the quantification of CR and MBV in humans.
Resumo:
We appreciate the comments and concerns expressed by Arakawa and colleagues regarding our article, titled “Pulsatile control of rotary blood pumps: Does the modulation waveform matter?”1 Unfortunately, we have to disagree with Arakawa and colleagues. As is obvious from the title of our article, it investigates the effect of different waveforms on the heart–device interaction. In contrast to the authors' claim, this is the first article in the literature that uses basic waveforms (sine, triangle, saw tooth, and rectangular) with different phase shifts to examines their impact on left ventricular unloading. The previous publications2, 3 and 4 just varied the pump speed during systole and diastole, which was first reported by Bearnson and associates5 in 1996, and studied its effect on aortic pressure, coronary flow, and end-diastolic volume. We should mention that dp/dtmax is a load-sensitive parameter of contractility and not representative for the degree of unloading. Moreover, none of the aforementioned reports has studied mechanical unloading and in particular the stroke work of the left ventricle. Our method is unique because we do not just alternate between high and low speed but have accurate control of the waveform because of the direct drive system of Levitronix Technologies LLC (Waltham, Mass) and a custom-developed pump controller. Without referring, Arakawa and associates state “several previous studies have already reported the coronary flow diminishes as the left ventricular assist device support increases.” It should be noted that all the waveforms used in our study have 2000 rpm average value with 1000 rpm amplitude, which is not an excessive speed for the CentriMag rotary pump (Levitronix) to collapse the ventricle and diminish the coronary flow. We agree with Arakawa and coworkers that there is a need for a heart failure model to come to more relevant results with respect to clinical expectations. However, we have explored many existing models, including species and breeds that have a native proneness to cardiomyopathy, but all of them differ from the genetic presentation in humans. We certainly do not believe that the use of microembolization, in which the coronary circulation is impaired by the injection of microspheres, would form a good model from which to draw conclusions about coronary flow change under different loading conditions. A model would be needed in which either an infarct is created to mimic ischemic heart failure or the coronary circulation remains untouched to simulate, for instance, dilated cardiomyopathy. Furthermore, in discussion we clearly mention that “lack of heart failure is a major limitation of our study.” We also believe that unloading is not the only factor of the cardiac functional recovery, and an excessive unloading of the left ventricle might lead to cardiac tissue atrophy. Therefore, in our article we mention that control of the level of cardiac unloading by assist devices has been suggested as a mechanical tool to promote recovery, and more studies are required to find better strategies for the speed modulation of rotary pumps and to achieve an optimal heart load control to enhance myocardial recovery. Finally, there are many publications about pulsing rotary blood pumps and it was impossible to include them all. We preferred to reference some of the earlier basic works such as an original research by Bearnson and coworkers5 and another article published by our group,6 which is more relevant.
Resumo:
Coronary collaterals are an alternative source of blood supply to myocardium jeopardized by ischaemia. Well-developed coronary collateral arteries in patients with coronary artery disease (CAD) mitigate myocardial infarcts and improve survival.
Resumo:
BACKGROUND: Minimal extracorporeal circulation (MECC) is a promising perfusion technology, taking the advantage of an ECC while having a significantly reduced priming volume. We analyzed the actual possible benefits of using MECC in patients undergoing CABG procedures and compared the results with conventional extracorporeal circulation (CECC). METHODS: One thousand fifty-three consecutive patients underwent CABG surgery using the MECC perfusion technique. Subgroup analyses focused on perioperative myocardial markers (cardiac troponin I [cTnI]), incidence of atrial fibrillation (AF), and perioperative evaluation of inflammatory markers and data were compared with those of patients who underwent CABG using CECC. A propensity score analysis was performed. RESULTS: Patient characteristics and distribution of EuroSCORE risk were similar in both groups. Severity of coronary artery disease and extent of revascularization were also comparable in both groups (number of distal anastomoses: 3.2 +/- 1.1 in CECC vs 3.2 +/- 0.9 in MECC; p = not significant [ns]). The cTnI was significantly lower in the MECC group (11.0 +/- 10.8 microg/L in MECC vs 24.7 +/- 25.3 microg/L in CECC; p < 0.05). Incidence of AF was 11.1% in MECC and 39.0% in CECC (p < 0.05). Inflammatory markers (interleukin-6, SC5b-9) were lower in MECC patients (p < 0.05). Propensity score analysis confirmed faster recovery in MECC patients and lower incidence of AF. CONCLUSIONS: Minimal extracorporeal circulation is a safe perfusion technique for CABG and may therefore concurrence OPCAB and traditional CABG under CECC.
Resumo:
AIMS The aim of our study in patients with coronary artery disease (CAD) and present, or absent, myocardial ischaemia during coronary occlusion was to test whether (i) left ventricular (LV) filling pressure is influenced by the collateral circulation and, on the other hand, that (ii) its resistance to flow is directly associated with LV filling pressure. METHODS AND RESULTS In 50 patients with CAD, the following parameters were obtained before and during a 60 s balloon occlusion: LV, aortic (Pao) and coronary pressure (Poccl), flow velocity (Voccl), central venous pressure (CVP), and coronary flow velocity after coronary angioplasty (V(Ø-occl)). The following variables were determined and analysed at 10 s intervals during occlusion, and at 60 s of occlusion: LV end-diastolic pressure (LVEDP), velocity-derived (CFIv) and pressure-derived collateral flow index (CFIp), coronary collateral (Rcoll), and peripheral resistance index to flow (Rperiph). Patients with ECG signs of ischaemia during coronary occlusion (insufficient collaterals, n = 33) had higher values of LVEDP over the entire course of occlusion than those without ECG signs of ischaemia during occlusion (sufficient collaterals, n = 17). Despite no ischaemia in the latter, there was an increase in LVEDP from 20 to 60 s of occlusion. In patients with insufficient collaterals, CFIv decreased and CFIp increased during occlusion. Beyond an occlusive LVEDP > 27 mmHg, Rcoll and Rperiph increased as a function of LVEDP. CONCLUSION Recruitable collaterals are reciprocally tied to LV filling pressure during occlusion. If poorly developed, they affect it via myocardial ischaemia; if well grown, LV filling pressure still increases gradually during occlusion despite the absence of ischaemia indicating transmission of collateral perfusion pressure to the LV. With low, but not high, collateral flow, resistance to collateral as well as coronary peripheral flow is related to LV filling pressure in the high range.
Resumo:
OBJECTIVES Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary artery bypass grafting (CABG) by electroencephalogram P300 wave event-related potentials and number connection test (NCT) as metrics of cognitive function. METHODS Cognitive brain function was assessed in 31 patients in 2013 with a mean age of 65 years [standard deviation (SD) 10] undergoing CABG by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds) directly prior to intervention, 7 days after and 3 months later. Number connection test, serving as method of control, was performed simultaneously in all patients. RESULTS Seven days following CABG, cognitive P300 evoked potentials were comparable with preoperative baseline values [vertex (Cz) 376 (SD 11) ms vs 378 (18) ms, P = 0.39; frontal (Fz) 377 (11) vs 379 (21) ms, P = 0.53]. Cognitive brain function at 3 months was compared with baseline values [(Cz) 376 (11) ms vs 371 (14 ms) P = 0.09; (Fz) 377 (11) ms vs 371 (15) ms, P = 0.04]. Between the first postoperative measurement and 3 months later, significant improvement was observed [(Cz) 378 (18) ms vs 371 (14) ms, P = 0.03; (Fz) 379 (21) vs 371 (15) ms, P = 0.02]. Similar clearly corresponding patterns could be obtained via the number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (P = 0.05) and (Fz) results (P = 0.04). CONCLUSIONS MECC does not adversely affect cognitive brain function after CABG. Additionally, these patients experience a substantial significant cognitive improvement after 3 months, evidentiary proving that the concept of MECC ensures safety and outcome in terms of brain function.
Resumo:
OBJECTIVE Coronary artery bypass grafting (CABG) using extracorporeal circulation (ECC) is still the gold standard. However, alternative techniques have been developed to avoid ECC and its potential adverse effects. These encompass minimal extracorporeal circulation (MECC) or off-pump coronary artery bypass grafting (OPCAB). However, the prevailing potential benefits when comparing MECC and OPCABG are not yet clearly established. METHODS In this retrospective study we investigated the potential benefits of MECC and OPCABG in 697 patients undergoing CABG. Of these, 555 patients had been operated with MECC and 142 off-pump. The primary endpoint was Troponin T level as an indicator for myocardial damage. RESULTS Study groups were not significantly different in general. However, patients undergoing OPCABG were significantly older (65.01 years ± 9.5 vs. 69.39 years ± 9.5; p value <0.001) with a higher Logistic EuroSCORE I (4.92% ± 6.5 vs. 5.88% ± 6.8; p value = 0.017). Operating off pump significantly reduced the need for intra-operative blood products (0.7% vs. 8.6%; p-value <0.001) and the length of stay in the intensive care unit (ICU) (2.04 days ± 2.63 vs. 2.76 days ± 2.79; p value <0.001). Regarding other blood values a significant difference could not be found in the adjusted calculations. The combined secondary endpoint, major cardiac or cerebrovascular events (MACCE), was equal in both groups as well. CONCLUSIONS Coronary artery bypass grafting using MECC or OPCABG are two comparable techniques with advantages for OPCABG regarding the reduced need for intra-operative blood products and shorter length of stay in the ICU. However serological values and combined endpoint MACCE did not differ significantly in both groups.
Resumo:
Gebiet: Chirurgie Abstract: Introduction: Carotid endarterectomy (CEA) and coronary artery bypass grafting (CABG) could be approached in a combined or a staged fashion. Some crucial studies have shown no significant difference in peri-operative stroke and death rate in combined versus staged CEA/CABG. At present conventional extracorporeal circulation (CECC) is regarded as the gold standard for performing on-pump coronary artery bypass grafting. On contrary, the use of minimized extracorporeal circulation (MECC) for CABG diminishes hemodilution, blood-air contact, foreign surface contact and inflammatory response. At the same time, general anaesthesia (GA) is a potential risk factor for higher perioperative stroke rate after isolated CEA, not only for the ipsilateral but also for the contralateral side especially in case of contralateral high-grade stenosis or occlusion. The aim of the study was to analyze if synchronous CEA/CABG using MECC (CEA/CABG group) allows reducing the perioperative stroke risk to the level of isolated CEA performed under GA (CEA-GA group). – Methods: A retrospective analysis of all patients who underwent CEA at our institution between January 2005 and December 2012 was performed. We compared outcomes between all patients undergoing CEA/CABG to all isolated CEA-GA during the same time period. The CEA/CABG group was additionally compared to a reference group consisting of patients undergoing isolated CEA in local anaesthesia. Primary outcome was in-hospital stroke. – Results: A total of 367 CEAs were performed, from which 46 patients were excluded having either off-pump CABG or other cardiac surgery procedures than CABG combined with CEA. Out of 321 patients, 74 were in the CEA/CABG and 64 in the CEA-GA group. There was a significantly higher rate of symptomatic stenoses among patients in the CEA-GA group (p<0.002). Three (4.1%) strokes in the CEA/CABG group were registered, two ipsilateral (2.7%) and one contralateral (1.4%) to the operated side. In the CEA-GA group 2 ipsilateral strokes (3.1%) occurred. No difference was noticed between the groups (p=1.000). One patient with stroke in each group had a symptomatic stenosis preoperatively. – Conclusions: Outcome with regard to mortality and neurologic injury is very good in both -patients undergoing CEA alone as well as patients undergoing synchronous CEA and CABG using the MECC system. Although the CEA/CABG group showed slightly increased risk of stroke, it can be considered as combined treatment in particular clinical situations.