19 resultados para Conventional approach

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: The reference surveillance method in patients with Barrett's esophagus is careful endoscopic observation, with targeted as well as random four-quadrant biopsies. Autofluorescence endoscopy (AFE) may make it easier to locate neoplasia. The aim of this study was to elucidate the diagnostic accuracy of surveillance with AFE-guided plus four-quadrant biopsies in comparison with the conventional approach. PATIENTS AND METHODS: A total of 187 of 200 consecutive Barrett's esophagus patients who were initially enrolled (73 % male, mean age 67 years, mean Barrett's segment length 4.6 cm), who underwent endoscopy for Barrett's esophagus in four study centers, were randomly assigned to undergo either AFE-targeted biopsy followed by four-quadrant biopsies or conventional endoscopic surveillance, also including four-quadrant biopsies (study phase 1). After exclusion of patients with early cancer or high-grade dysplasia, who underwent endoscopic or surgical treatment, as well as those who declined to participate in phase 2 of the study, 130 patients remained. These patients were examined again with the alternative method after a mean of 10 weeks, using the same methods described. The main study parameter was the detection of early cancer/adenocarcinoma or high-grade dysplasia (HGD), comparing both approaches in study phase 1; the secondary study aim in phase 2 was to assess the additional value of the AFE-guided approach after conventional surveillance, and vice versa. Test accuracy measures were derived from study phase 1. RESULTS: In study phase 1, the AFE and conventional approaches yielded adenocarcinoma/HGD rates of 12 % and 5.3 %, respectively, on a per-patient basis. With AFE, four previously unrecognized adenocarcinoma/HGD lesions were identified (4.3 % of the patients); with the conventional approach, one new lesion (1.1 %) was identified. Of the 19 adenocarcinoma/HGD lesions detected during AFE endoscopy in study phase 1, eight were visualized, while 11 were only detected using untargeted four-quadrant biopsies (sensitivity 42 %). Of the 766 biopsies classified at histology as being nonneoplastic, 58 appeared suspicious (specificity 92 %, positive predictive value 12 %, negative predictive value 98.5 %). In study phase 2, AFE detected two further lesions in addition to the initial alternative approach in 3.2 % of cases, in comparison with one lesion with conventional endoscopy (1.7 %). CONCLUSIONS: In this referral Barrett's esophagus population with a higher prevalence of neoplastic lesions, the AFE-guided approach improved the diagnostic yield for neoplasia in comparison with the conventional approach using four-quadrant biopsies. However, AFE alone was not suitable for replacing the standard four-quadrant biopsy protocol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Brain lesions in the visual associative cortex are known to impair visual perception, i.e., the capacity to correctly perceive different aspects of the visual world, such as motion, color, or shapes. Visual perception can be influenced by non-invasive brain stimulation such as transcranial direct current stimulation (tDCS). In a recently developed technique called high definition (HD) tDCS, small HD-electrodes are used instead of the sponge electrodes in the conventional approach. This is believed to achieve high focality and precision over the target area. In this paper we tested the effects of cathodal and anodal HD-tDCS over the right V5 on motion and shape perception in a single blind, within-subject, sham controlled, cross-over trial. The purpose of the study was to prove the high focality of the stimulation only over the target area. Twenty one healthy volunteers received 20 min of 2 mA cathodal, anodal and sham stimulation over the right V5 and their performance on a visual test was recorded. The results showed significant improvement in motion perception in the left hemifield after cathodal HD-tDCS, but not in shape perception. Sham and anodal HD-tDCS did not affect performance. The specific effect of influencing performance of visual tasks by modulating the excitability of the neurons in the visual cortex might be explained by the complexity of perceptual information needed for the tasks. This provokes a "noisy" activation state of the encoding neuronal patterns. We speculate that in this case cathodal HD-tDCS may focus the correct perception by decreasing global excitation and thus diminishing the "noise" below threshold.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Sutureless aortic valve replacement (SU-AVR) has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to reduce cross-clamp and cardiopulmonary bypass (CPB) duration and thereby improve surgical outcomes and facilitate a minimally invasive approach suitable for higher risk patients. The present systematic review and meta-analysis aims to assess the safety and efficacy of SU-AVR approach in the current literature. METHODS Electronic searches were performed using six databases from their inception to January 2014. Relevant studies utilizing sutureless valves for aortic valve implantation were identified. Data were extracted and analyzed according to predefined clinical endpoints. RESULTS Twelve studies were identified for inclusion of qualitative and quantitative analyses, all of which were observational reports. The minimally invasive approach was used in 40.4% of included patients, while 22.8% underwent concomitant coronary bypass surgery. Pooled cross-clamp and CPB duration for isolated AVR was 56.7 and 46.5 minutes, respectively. Pooled 30-day and 1-year mortality rates were 2.1% and 4.9%, respectively, while the incidences of strokes (1.5%), valve degenerations (0.4%) and paravalvular leaks (PVL) (3.0%) were acceptable. CONCLUSIONS The evaluation of current observational evidence suggests that sutureless aortic valve implantation is a safe procedure associated with shorter cross-clamp and CPB duration, and comparable complication rates to the conventional approach in the short-term.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE Treatment of vascular malformations requires the placement of a needle within vessels which may be as small as 1 mm, with the current state of the art relying exclusively on two-dimensional fluoroscopy images for guidance. We hypothesize that the combination of stereotactic image guidance with existing targeting methods will result in faster and more reproducible needle placements, as well as reduced radiationexposure, when compared to standard methods based on fluoroscopy alone. METHODS The proposed navigation approach was evaluated in a phantom experiment designed to allow direct comparison with the conventional method. An anatomical phantom of the left forearm was constructed, including an independent control mechanism to indicate the attainment of the target position. Three interventionalists (one inexperienced, two of them frequently practice the conventional fluoroscopic technique) performed 45 targeting attempts utilizing the combined and 45 targeting attempts utilizing the standard approaches. RESULTS In all 45 attempts, the users were able to reach the target when utilizing the combined approach. In two cases, targeting was stopped after 15 min without reaching the target when utilizing only the C-arm. The inexperienced user was faster when utilizing the combined approach and applied significantly less radiation than when utilizing the conventional approach. Conversely, both experienced users were faster when using the conventional approach, in one case significantly so, with no significant difference in radiation dose when compared to the combined approach. CONCLUSIONS This work presents an initial evaluation of a combined navigation fluoroscopy targeting technique in a phantom study. The results suggest that, especially for inexperienced interventionalists, navigation may help to reduce the time and the radiation dose. Future work will focus on the improvement and clinical evaluation of the proposed method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resilience research has been applied to socioeconomic as well as for agroecological studies in the last 20 years. It provides a conceptual and methodological approach for a better understanding of interrelations between the performance of ecological and social systems. In the research area Alto Beni, Bolivia, the production of cocoa (Theobroma cacao L.), is one of the main sources of income. Farmers in the region have formed producers’ associations to enhance organic cocoa cultivation and obtain fair prices since the 1980s. In cooperation with the long-term system comparisons by the Research Institute of Organic Agriculture (FiBL) in Alto Beni, aspects of the field trial are applied for the use in on-farm research: a comparison of soil fertility, biomass and crop diversity is combined with qualitative interviews and participatory observation methods. Fieldwork is carried out together with Bolivian students through the Swiss KFPE-programme Echanges Universitaires. For the system comparisons, four different land-use types were classified according to their ecological complexity during a preliminary study in 2009: successional agroforestry systems, simple agroforestry systems (both organically managed and certified), traditional systems and conventional monocultures. The study focuses on interrelations between different ways of cocoa cultivation, livelihoods and the related socio-cultural rationales behind them. In particular this second aspect is innovative as it allows to broaden the biophysical perspective to a more comprehensive evaluation with socio-ecological aspects thereby increasing the relevance of the agronomic field studies for development policy and practice. Moreover, such a socio-ecological baseline allows to assess the potential of organic agriculture regarding resilience-building face to socio-environmental stress factors. Among others, the results of the pre-study illustrate local farmers’ perceptions of climate change and the consequences for the different crop-systems: all interviewees mentioned rising temperatures and/or an extended dry season as negative impacts more with regard to their own working conditions than to their crops. This was the case in particular for conventional monocultures and in plots where slash-and-burn cultivation was practised whereas for organic agroforestry systems the advantage of working in the shade was stressed indicating that their relevance rises in the context of climate change.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The most common techniques to perform stellate ganglion blocks (SGBs) are the blind C6 approach and the fluoroscopic-controlled paratracheal C7 approach, both after manual dislocation of the large vessels. Complications due to vascular or esophageal puncture have been reported. The goal of this ultrasound imaging study was to determine how frequently hazardous structures are located along the needle path of conventional SGB and to determine the influence of the dislocation maneuver on their position.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Streptococcus spp. and related bacteria form a large group of organisms which are associated with bovine intramammary Infections (IMI). Some of them are the well-known mastitis pathogens Streptococcus uberis and Streptococcus agalactiae. In addition, there are a considerable number of these gram-positive, catalase-negative cocci (PNC) with unclear mastitic pathogenicity such as Aerococcus viridans which make the conventional diagnostics of PNC difficult. One diagnostic, API 20 Strep (API, Biomerieux) is recommended which, as a phenotypic assay, involves a series of miniaturized biochemical tests. Recently, preference is given to genotypic identification methods. In particular, sequencing of the 16S rRNA gene allows highly reproducible and accurate identification of bacteria and permits discovery of novel, clinically relevant bacteria. As a consequence, the aim of the present study was to compare identification of IMI-associated PNC by the API method as well as by sequencing of their 16S rRNA gene (16S). Furthermore, the correlation of these bacteria to bovine chronic mastitis and their phylogeny was investigated. 102 PNC isolated from single quarter milk samples were identified by API and 16S sequencing. Considering Streptococcus uberis, Streptococcus dysgalactiae subsp. dysgalactiae and Streptococcus agalactiae, both methods generated fully concordant results. In contrast, a very high disconcordance was observed for most of the other PNC, in particular Enterococcus spp., Aerococcus viridans and the viridans streptococci were shown as apathogenic. Lactococcus garvieae was found to be an opportunistic pathogen causing IMI during late lactation. In addition, PNC isolated from milk were frequently observed together with other bacteria, in particular with Staphylococcus spp. In these cases, the levels of somatic cell counts (SCC) were determined by the specific PNC present in the sample. Considering PNC phylogeny based on 16S sequencing, 3 major clusters were observed. They included all the common mastitis pathogens (cluster I), the Lactococcus spp., Enterococcus spp. and Aerococcus spp. (cluster II) and all the viridans streptococci (cluster III).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Triggered event-related functional magnetic resonance imaging requires sparse intervals of temporally resolved functional data acquisitions, whose initiation corresponds to the occurrence of an event, typically an epileptic spike in the electroencephalographic trace. However, conventional fMRI time series are greatly affected by non-steady-state magnetization effects, which obscure initial blood oxygen level-dependent (BOLD) signals. Here, conventional echo-planar imaging and a post-processing solution based on principal component analysis were employed to remove the dominant eigenimages of the time series, to filter out the global signal changes induced by magnetization decay and to recover BOLD signals starting with the first functional volume. This approach was compared with a physical solution using radiofrequency preparation, which nullifies magnetization effects. As an application of the method, the detectability of the initial transient BOLD response in the auditory cortex, which is elicited by the onset of acoustic scanner noise, was used to demonstrate that post-processing-based removal of magnetization effects allows to detect brain activity patterns identical with those obtained using the radiofrequency preparation. Using the auditory responses as an ideal experimental model of triggered brain activity, our results suggest that reducing the initial magnetization effects by removing a few principal components from fMRI data may be potentially useful in the analysis of triggered event-related echo-planar time series. The implications of this study are discussed with special caution to remaining technical limitations and the additional neurophysiological issues of the triggered acquisition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three different fissure preparation procedures were tested and compared to the non-invasive approach using a conventional unfilled sealant and a flowable composite. Eighty permanent molars were selected and divided into 4 groups of 20 teeth each. All the teeth were split into 2 halves, and the exposed fissures were photographed under a microscope (35x) before and after being prepared using the following methods: (I) Er:YAG laser (KEY Laser, KaVo) 600 mJ pulse energy, 6 Hz; (II) diamond bur; (III) Er: YAG laser (KEY Laser, KaVo) 200 mJ pulse energy, 4 Hz; (IV) Control group: Powder jet cleaner (Prophyflex, KaVo, Germany). The pre-and postimages were superimposed in order to evaluate the amount of hard tissue removed. Ten teeth in each group were then acid etched and sealed with an unfilled sealant (Delton opaque, Dentsply), while the remaining 10 teeth were acid etched, primed and bonded (Prime ; Bond NT, Dentsply) and sealed with a flowable composite (X-flow, DeTrey, Dentsply). Material penetration and microleakage were evaluated after thermocycling (5000 cycles) and staining with methylene blue 5%. ANOVA and Mann-Whitney tests were applied for statistical analysis. The laser 600 mJ and bur eliminated the greatest amount of hard tissue. The control teeth presented the least microleakage when sealed with Delton or X-flow. A correlation between material penetration and microleakage could not be statistically confirmed. Mechanical preparation prior to fissure sealing did not enhance the final performance of the sealant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new technique was evaluated to identify changes in bone metabolism directly at high sensitivity through isotopic labeling of bone Ca. Six women with low BMD were labeled with 41Ca up to 700 days and treated for 6 mo with risedronate. Effect of treatment on bone could be identified using 41Ca after 4-8 wk in each individual. INTRODUCTION: Isotopic labeling of bone using 41Ca, a long-living radiotracer, has been proposed as an alternative approach for measuring changes in bone metabolism to overcome current limitations of available techniques. After isotopic labeling of bone, changes in urinary 41Ca excretion reflect changes in bone Ca balance. The aim of this study was to validate this new technique against established measures. Changes in bone Ca balance were induced by giving a bisphosphonate. MATERIALS AND METHODS: Six postmenopausal women with diagnosed osteopenia/osteoporosis received a single oral dose of 100 nCi 41Ca for skeleton labeling. Urinary 41Ca/40Ca isotope ratios were monitored by accelerator mass spectrometry up to 700 days after the labeling process. Subjects received 35 mg risedronate per week for 6 mo. Effect of treatment was monitored using the 41Ca signal in urine and parallel measurements of BMD by DXA and biochemical markers of bone metabolism in urine and blood. RESULTS: Positive response to treatment was confirmed by BMD measurements, which increased for spine by +3.0% (p = 0.01) but not for hip. Bone formation markers decreased by -36% for bone alkaline phosphatase (BALP; p = 0.002) and -59% for procollagen type I propeptides (PINP; p = 0.001). Urinary deoxypyridinoline (DPD) and pyridinoline (PYD) were reduced by -21% (p = 0.019) and -23% (p = 0.009), respectively, whereas serum and urinary carboxy-terminal teleopeptides (CTXs) were reduced by -60% (p = 0.001) and -57.0% (p = 0.001), respectively. Changes in urinary 41Ca excretion paralleled findings for conventional techniques. The urinary 41Ca/40Ca isotope ratio was shifted by -47 +/- 10% by the intervention. Population pharmacokinetic analysis (NONMEM) of the 41Ca data using a linear three-compartment model showed that bisphosphonate treatment reduced Ca transfer rates between the slowly exchanging compartment (bone) and the intermediate fast exchanging compartment by 56% (95% CI: 45-58%). CONCLUSIONS: Isotopic labeling of bone using 41Ca can facilitate human trials in bone research by shortening of intervention periods, lowering subject numbers, and having easier conduct of cross-over studies compared with conventional techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Distinguishing organic and conventional products is a major issue of food security and authenticity. Previous studies successfully used stable isotopes to separate organic and conventional products, but up to now, this approach was not tested for organic grassland hay and soil. Moreover, isotopic abundances could be a powerful tool to elucidate differences in ecosystem functioning and driving mechanisms of element cycling in organic and conventional management systems. Here, we studied the delta N-15 and delta C-13 isotopic composition of soil and hay samples of 21 organic and 34 conventional grasslands in two German regions. We also used Delta delta N-15 (delta N-15 plant - delta N-15 soil) to characterize nitrogen dynamics. In order to detect temporal trends, isotopic abundances in organic grasslands were related to the time since certification. Furthermore, discriminant analysis was used to test whether the respective management type can be deduced from observed isotopic abundances. Isotopic analyses revealed no significant differences in delta C-13 in hay and delta C-13 in both soil and hay between management types, but showed that delta C-13 abundances were significantly lower in soil of organic compared to conventional grasslands. delta C-15 values implied that management types did not substantially differ in nitrogen cycling. Only delta C-13 in soil and hay showed significant negative relationships with the time since certification. Thus, our result suggest that organic grasslands suffered less from drought stress compared to conventional grasslands most likely due to a benefit of higher plant species richness, as previously shown by manipulative biodiversity experiments. Finally, it was possible to correctly classify about two third of the samples according to their management using isotopic abundances in soil and hay. However, as more than half of the organic samples were incorrectly classified, we infer that more research is needed to improve this approach before it can be efficiently used in practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article we argue that it is pressing to study the “hybrid media system” at the intersection of online and offl ine communication and its potential for agenda building. The topic is relevant because it is argued that the internet off ers new opportunities of public infl uence for challengers without access to political decision making. Except for single case studies, little is known about the conditions under which these actors succeed. Informed by the research on agenda building we tackle with the mechanisms of online-offline media agenda building and the conditions under which challengers succeed to produce issue spill-over into conventional mass media. We develop a theoretical framework for investigating the linkage between online communication and traditional mass media and discuss how our model translates into empirical research. We conclude that the nature of online networks is critical for spill-over, but also the issue itself and the structure of the political system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we propose a fully automatic, robust approach for segmenting proximal femur in conventional X-ray images. Our method is based on hierarchical landmark detection by random forest regression, where the detection results of 22 global landmarks are used to do the spatial normalization, and the detection results of the 59 local landmarks serve as the image cue for instantiation of a statistical shape model of the proximal femur. To detect landmarks in both levels, we use multi-resolution HoG (Histogram of Oriented Gradients) as features which can achieve better accuracy and robustness. The efficacy of the present method is demonstrated by experiments conducted on 150 clinical x-ray images. It was found that the present method could achieve an average point-to-curve error of 2.0 mm and that the present method was robust to low image contrast, noise and occlusions caused by implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Engineers are confronted with the energy demand of active medical implants in patients with increasing life expectancy. Scavenging energy from the patient’s body is envisioned as an alternative to conventional power sources. Joining in this effort towards human-powered implants, we propose an innovative concept that combines the deformation of an artery resulting from the arterial pressure pulse with a transduction mechanism based on magneto-hydrodynamics. To overcome certain limitations of a preliminary analytical study on this topic, we demonstrate here a more accurate model of our generator by implementing a three-dimensional multiphysics finite element method (FEM) simulation combining solid mechanics, fluid mechanics, electric and magnetic fields as well as the corresponding couplings. This simulation is used to optimize the generator with respect to several design parameters. A first validation is obtained by comparing the results of the FEM simulation with those of the analytical approach adopted in our previous study. With an expected overall conversion efficiency of 20% and an average output power of 30 μW, our generator outperforms previous devices based on arterial wall deformation by more than two orders of magnitude. Most importantly, our generator provides sufficient power to supply a cardiac pacemaker.