33 resultados para Contrast Agent
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.
Resumo:
Postmortem investigation is increasingly supported by computed tomography (CT) and magnetic resonance imaging, in which postmortem minimal invasive angiography has become important. The newly introduced approach using an aqueous contrast agent solution provided excellent vessel visualization but was suspected to possibly cause tissue edema artifacts in histological investigations. The aim of this study was to investigate on a porcine heart model whether it is possible to influence the contrast agent distribution within the soft tissue by changing its viscosity by dissolving the contrast agent in polyethylene glycol (PEG) as a matrix medium. High-resolution CT scans after injection showed that viscosities above c. 15 mPa s (65% PEG) prevented a contrast agent distribution within the capillary bed of the left ventricular myocardium. Thereby, the precondition of edema artifacts could be reduced. Its minimal invasive application on human corpses needs to be further adapted as the flow resistance is expected to differ between different tissues.
Resumo:
The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.
Resumo:
Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.
Resumo:
The purpose of this study was to determine the influence of iodinated contrast agents on the formation of DNA double-strand breaks in vitro in lymphocytes and to verify these results in patients undergoing diagnostic computed tomography examinations. Blood samples were irradiated in vitro in the presence of iodinated X-ray contrast agent. Controls were irradiated without contrast agent. Fourteen patients were investigated using contrast-enhanced computed tomography (CT), and 14 other patients with unenhanced CT. Blood samples were taken prior to and 5 min and 1, 2 and 24 h after the CT examination. In these blood samples the average number of γH2Ax-foci per lymphocyte was enumerated by fluorescence microscopy. Statistical differences between foci numbers developed in the presence and absence of contrast agent were tested using an independent sample t-test. In vitro foci numbers after irradiation were significantly higher when contrast agent was present during irradiation. In vivo, γH2Ax-foci levels were 58% higher in patients undergoing contrast-enhanced CT compared with those undergoing unenhanced CT. In the presence of iodinated contrast agents DNA, damage is increased and the radiation dose is not the only factor affecting the amount of DNA damage. Individual patient characteristics and biological dosimetry applications, e.g. the analysis of γH2Ax-foci, have to be considered.
Resumo:
OBJECTIVE: The objective of our study was to establish a standardized procedure for postmortem whole-body CT-based angiography with lipophilic and hydrophilic contrast media solutions and to compare the results of these two methods. MATERIALS AND METHODS: Minimally invasive postmortem CT angiography was performed on 10 human cadavers via access to the femoral blood vessels. Separate perfusion of the arterial and venous systems was established with a modified heart-lung machine using a mixture of an oily contrast medium and paraffin (five cases) and a mixture of a water-soluble contrast medium with polyethylene glycol (PEG) 200 in the other five cases. Imaging was executed with an MDCT scanner. RESULTS: The minimally invasive femoral approach to the vascular system provided a good depiction of lesions of the complete vascular system down to the level of the small supplying vessels. Because of the enhancement of well-vascularized tissues, angiography with the PEG-mixed contrast medium allowed the detection of tissue lesions and the depiction of vascular abnormalities such as pulmonary embolisms or ruptures of the vessel wall. CONCLUSION: The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues (cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.
Resumo:
To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P < 0.001), homogeneity of the luminal content (P < 0.001), delineation of the bowel-wall to the lumen (P < 0.001) and to the mesentery (P < 0.001) and artifacts (P < 0.001), leading to a significant better overall image quality (P < 0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P < 0.001) and wall to lumen delineation (P < 0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population.
Resumo:
PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.
Resumo:
In contrast-enhanced (CE) MR myelography, hyperintense signal outside the intrathecal space in T1-weighted sequences with spectral presaturation inversion recovery (SPIR) is usually considered to be due to CSF leakage. We retrospectively investigated a hyperintense signal at the apex of the lung appearing in this sequence in patients with SIH (n = 5), CSF rhinorrhoea (n = 2), lumbar spine surgery (n = 1) and in control subjects (n = 6). Intrathecal application of contrast agent was performed in all patients before MR examination, but not in the control group. The reproducible signal increase was investigated with other fat suppression techniques and MR spectroscopy. All patients and controls showed strongly hyperintense signal at the apex of the lungs imitating CSF leakage into paraspinal tissue. This signal increase was identified as an artefact, caused by spectroscopically proven shift and broadening of water and lipid resonances (1-2 ppm) in this anatomical region. Only patients with SIH showed additional focal enhancement along the spinal nerve roots and/or in the spinal epidural space. In conclusion CE MR myelography with spectral selective fat suppression shows a reproducible cervicothoracic artefact, imitating CSF leakage. Selective water excitation technique as well as periradicular and epidural contrast collections may be helpful to discriminate between real pathological findings and artefacts.
Resumo:
PURPOSE To determine the effect of the use of iodinated contrast agents on the formation of DNA double-strand breaks during chest computed tomography (CT). MATERIALS AND METHODS This study was approved by the institutional review board, and written informed consent was obtained from all patients. This single-center study was performed at a university hospital. A total of 179 patients underwent contrast material-enhanced CT, and 66 patients underwent unenhanced CT. Blood samples were taken from these patients prior to and immediately after CT. In these blood samples, the average number of phosphorylated histone H2AX (γH2AX) foci per lymphocyte was determined with fluorescence microscopy. Significant differences between the number of foci that developed in both the presence and the absence of the contrast agent were tested by using an independent sample t test. RESULTS γH2AX foci levels were increased in both groups after CT. Patients who underwent contrast-enhanced CT had an increased amount of DNA radiation damage (mean increase ± standard error of the mean, 0.056 foci per cell ± 0.009). This increase was 107% ± 19 higher than that in patients who underwent unenhanced CT (mean increase, 0.027 foci per cell ± 0.014). CONCLUSION The application of iodinated contrast agents during diagnostic x-ray procedures, such as chest CT, leads to a clear increase in the level of radiation-induced DNA damage as assessed with γH2AX foci formation.
Resumo:
Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.
Resumo:
PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0-not visualized; 3-excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3mm versus 4.9±1.3mm [P<0.05] and 3.7±1.3mm versus 2.6±0.5mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.
Resumo:
BACKGROUND: Recent studies have focused on mechanical thrombectomy as a means to reduce the time required for revascularization and increase the revascularization rate in acute stroke. To date no systematic evaluation has been made of the different mechanical devices in this novel and fast-developing field of endovascular interventions. To facilitate such evaluations, we developed a specific in vivo model for mechanical thrombectomy that allows visualization of dislocation or fragmentation of the thrombus during angiographic manipulation. METHODS: Angiography and embolization with a preformed thrombus was performed in 8 swine. The thrombus was generated by mixing 25 IU bovine thrombin and 10 mL autologous blood. For visualization during angiography, 1 g barium sulfate was added. RESULTS: The preformed thrombus exhibited mechanical stability, reproducibility, and high radiographic absorption, providing excellent visibility during angiography. The setting allowed selective embolization of targeted vessels without thrombus fragmentation. Despite the application of barium sulfate no local or systemic reaction occurred. Histologic evaluation revealed no intimal damage caused by the thrombus or contrast agent washout. CONCLUSION: The model presented here allows selective and reliable thromboembolization of vessels that reproduce the anatomic and hemodynamic situation in acute cerebrovascular stroke. It permits visualization of the thrombus during angiography and intervention, providing unique insight into the behavior of both thrombus and device, which is potentially useful in the development and evaluation of mechanical clot retrieval in acute cerebrovascular stroke.
Resumo:
AIMS: The adaptation of the myocardial microcirculation in humans to pathologic and physiologic stress has not been examined in vivo so far. We sought to test whether the relative blood volume (rBV) measured by myocardial contrast echocardiography (MCE) can differentiate between left ventricular (LV) hypertrophy (LVH) in hypertensive heart disease and athlete's heart. METHODS AND RESULTS: Four groups were investigated: hypertensive patients with LVH (n = 15), semi-professional triathletes with LVH (n = 15), professional football players (n = 15), and sedentary control individuals without cardiovascular disease (n = 15). MCE was performed at rest and during adenosine-induced hyperaemia. The rBV (mL mL(-1)), its exchange frequency (beta, min(-1)), and myocardial blood flow (mL min(-1) g(-1)) were derived from steady state and refill sequences of ultrasound contrast agent. Hypertensive patients had lower rBV (0.093 +/- 0.013 mL mL(-1)) than triathletes (0.141 +/- 0.012 mL mL(-1), P < 0.001), football players (0.129 +/- 0.014 mL mL(-1), P < 0.001), and sedentary individuals (0.126 +/- 0.018 mL mL(-1), P < 0.001). Conversely, the exchange frequency (beta) was significantly higher in hypertensive patients (11.3 +/- 3.8 min(-1)) than in triathletes (7.4 +/- 1.8 min(-1)), football players (7.7 +/- 2.3 min(-1)), and sedentary individuals (9.0+/-2.5 min(-1)). An rBV below 0.114 mL mL(-1) distinguished hypertensive patients and triathletes with a sensitivity of 93% and a specificity of 100%. CONCLUSION: Pathologic and physiologic LVH were differentiated non-invasively and accurately by rBV, a measure of vascularisation assessed by MCE.
Resumo:
PURPOSE: The aim of this study was to investigate the effect of magnetization transfer on multislice T(1) and T(2) measurements of articular cartilage. MATERIALS AND METHODS: A set of phantoms with different concentrations of collagen and contrast agent (Gd-DTPA(2-)) were used for the in vitro study. A total of 20 healthy knees were used for the in vivo study. T(1) and T(2) measurements were performed using fast-spin-echo inversion-recovery (FSE-IR) sequence and multi-spin-echo (MSE) sequence, respectively, in both in vitro and in vivo studies. We investigated the difference in T(1) and T(2) values between that measured by single-slice acquisition and that measured by multislice acquisition. RESULTS: Regarding T(1) measurement, a large drop of T(1) in all slices and also a large interslice variation in T(1) were observed when multislice acquisition was used. Regarding T(2) measurement, a substantial drop of T(2) in all slices was observed; however, there was no apparent interslice variation when multislice acquisition was used. CONCLUSION: This study demonstrated that the adaptation of multislice acquisition technique for T(1) measurement using FSE-IR methodology is difficult and its use for clinical evaluation is problematic. In contrast, multislice acquisition for T(2) measurement using MSE was clinically applicable if inaccuracies caused by multislice acquisition were taken into account. J. Magn. Reson. Imaging 2007;26:109-117. (c) 2007 Wiley-Liss, Inc.