143 resultados para Continuous coverage

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECT The authors developed a new mapping technique to overcome the temporal and spatial limitations of classic subcortical mapping of the corticospinal tract (CST). The feasibility and safety of continuous (0.4-2 Hz) and dynamic (at the site of and synchronized with tissue resection) subcortical motor mapping was evaluated. METHODS The authors prospectively studied 69 patients who underwent tumor surgery adjacent to the CST (< 1 cm using diffusion tensor imaging and fiber tracking) with simultaneous subcortical monopolar motor mapping (short train, interstimulus interval 4 msec, pulse duration 500 μsec) and a new acoustic motor evoked potential alarm. Continuous (temporal coverage) and dynamic (spatial coverage) mapping was technically realized by integrating the mapping probe at the tip of a new suction device, with the concept that this device will be in contact with the tissue where the resection is performed. Motor function was assessed 1 day after surgery, at discharge, and at 3 months. RESULTS All procedures were technically successful. There was a 1:1 correlation of motor thresholds for stimulation sites simultaneously mapped with the new suction mapping device and the classic fingerstick probe (24 patients, 74 stimulation points; r(2) = 0.98, p < 0.001). The lowest individual motor thresholds were as follows: > 20 mA, 7 patients; 11-20 mA, 13 patients; 6-10 mA, 8 patients; 4-5 mA, 17 patients; and 1-3 mA, 24 patients. At 3 months, 2 patients (3%) had a persistent postoperative motor deficit, both of which were caused by a vascular injury. No patient had a permanent motor deficit caused by a mechanical injury of the CST. CONCLUSIONS Continuous dynamic mapping was found to be a feasible and ergonomic technique for localizing the exact site of the CST and distance to the motor fibers. The acoustic feedback and the ability to stimulate the tissue continuously and exactly at the site of tissue removal improves the accuracy of mapping, especially at low (< 5 mA) stimulation intensities. This new technique may increase the safety of motor eloquent tumor surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is unknown whether sorafenib can be combined with transarterial chemoembolization (TACE) in patients with hepatocellular carcinoma. This study assesses the safety and tolerability of a continuous regimen of sorafenib combined with TACE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Induced mild hypothermia after cardiac arrest interferes with clinical assessment of the cardiovascular status of patients. In this situation, non-invasive cardiac output measurement could be useful. Unfortunately, arterial pulse contour is altered by temperature, and the performance of devices using arterial blood pressure contour analysis to derive cardiac output may be insufficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sunitinib (SU) is a multitargeted tyrosine kinase inhibitor with antitumor and antiangiogenic activity. The objective of this trial was to demonstrate antitumor activity of continuous SU treatment in patients with hepatocellular carcinoma (HCC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to characterize empirically the association between vaccination coverage and the size and occurrence of measles epidemics in Germany. In order to achieve this we analysed data routinely collected by the Robert Koch Institute, which comprise the weekly number of reported measles cases at all ages as well as estimates of vaccination coverage at the average age of entry into the school system. Coverage levels within each federal state of Germany are incorporated into a multivariate time-series model for infectious disease counts, which captures occasional outbreaks by means of an autoregressive component. The observed incidence pattern of measles for all ages is best described by using the log proportion of unvaccinated school starters in the autoregressive component of the model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Delayed cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH) is a major cause of high morbidity and mortality. The reduced availability of nitric oxide (NO) in blood and cerebrospinal fluid (CSF) is well established as a key mechanism of vasospasm. Systemic administration of glyceryl trinitrate (GTN), an NO donor also known as nitroglycerin, has failed to be established in clinical settings to prevent vasospasm because of its adverse effects, particularly hypotension. The purpose of this study was to analyze the effect of intrathecally administered GTN on vasospasm after experimental SAH in the rabbit basilar artery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study aims to identify risk constellations for symptomatic spinal cord malperfusion in patients undergoing extensive stent-graft coverage of the thoracic aorta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre has the potential for immediate and delayed neurological and vascular symptoms. Some authors, therefore, propose prophylactic revascularisation of the LSA by transposition or bypass, while others suggest prophylactic revascularisation only under certain conditions, and still others see no requirement for prophylactic revascularisation in anticipation of LSA ostium coverage. In this review about LSA revascularisation in TEVAR patients with coverage of the LSA, we searched the electronic databases MEDLINE and EMBASE historically until the end date of May 2010 with the search terms left subclavian artery, covering, endovascular, revascularisation and thoracic aorta. We have gathered the most complete scientific evidence available used to support the various concepts to deal with this issue. After a review of the current available literature, 23 relevant articles were found, where we have identified and analysed three basic treatment concepts for LSA revascularisation in TEVAR patients (prophylactic, conditional prophylactic and no prophylactic LSA revascularisation). The available evidence supports prophylactic revascularisation of the LSA before ESG LSA coverage when preoperative imaging reveals abnormal supra-aortic vascular anatomy or pathology. We further conclude that elective patients undergoing planned coverage of the LSA during TEVAR should receive prophylactic LSA transposition or LSA-to-left-common-carotid-artery (LCCA) bypass surgery to prevent severe neurological complications, such as paraplegia or brain stem infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Standard indicators of quality of care have been developed in the United States. Limited information exists about quality of care in countries with universal health care coverage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background—Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. Methods and Results—Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I2=38.40) but not in the other comparisons. Conclusions—Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas–volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gamma zero-lag phase synchronization has been measured in the animal brain during visual binding. Human scalp EEG studies used a phase locking factor (trial-to-trial phase-shift consistency) or gamma amplitude to measure binding but did not analyze common-phase signals so far. This study introduces a method to identify networks oscillating with near zero-lag phase synchronization in human subjects.