3 resultados para Consumption Values

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Energy consumption modelling by state based approaches often assume constant energy consumption values in each state. However, it happens in certain situations that during state transitions or even during a state the energy consumption is not constant and does fluctuate. This paper discusses those issues by presenting some examples from wireless sensor and wireless local area networks for such cases and possible solutions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

For driving aptitude assessment (DAA), the analysis of several alcohol biomarkers is essential for the detection of alcohol intake besides psycho-medical exploration. In Switzerland, EtG in hair (hEtG) is often the only direct marker for abstinence monitoring in DAA. Therefore, the suitability of phosphatidylethanol (PEth) was investigated as additional biomarker. PEth 16:0/18:1 and 16:0/18:2 were determined by online-SPE-LC-MS/MS in 136 blood samples of persons undergoing DAA and compared to hEtG, determined in hair segments taken at the same time. With a PEth 16:0/18:1 threshold of 210 ng/mL for excessive alcohol consumption, all (n = 30) but one tested person also had hEtG values ≥30 pg/mg. In 54 cases, results are not in contradiction to an abstinence as neither PEth (<20 ng/mL) nor hEtG (<7 pg/mg) was detected. In eight cases, both markers showed moderate consumption. Altogether, PEth and hEtG were in accordance in 68 % of the samples, although covering different time periods of alcohol consumption. With receiver operating characteristic analysis, PEth was evaluated to differentiate abstinence, moderate, and excessive alcohol consumption in accordance with hEtG limits. A PEth 16:0/18:1 threshold of 150 ng/mL resulted in the best sensitivity (70.6 %) and specificity (98.8 %) for excessive consumption. Values between 20 and 150 ng/mL passed for moderate consumption, values <20 ng/mL passed for abstinence. As PEth mostly has a shorter detection window (2-4 weeks) than hEtG (up to 6 months depending on hair length), changes in drinking behavior can be detected earlier by PEth than by hEtG analysis alone. Therefore, PEth helps to improve the diagnostic information and is a valuable additional alcohol marker for DAA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The oxygen consumption (VO2 microL/h/mg) of sham and of traumatized rat brains within 30 min and 6 h after a lateral fluid percussion injury (FPI) was measured with the Cartesian microrespirometer. Brain slices were cut at the plain of injury and site-specific 20-60-microg cores of tissue were transferred to the microrespirometer. In sham brains, the cortical VO2 (CVO2) was 13.78+/-0.64 and the hippocampal VO2 (HPVO2) was 11.20+/-0.58 microL/h/mg (p<0.05). Within 30 min of the injury, the respective values of 16.89+/-0.55 and 14.91+/-0.06 were significantly increased (p<0.05). The combined VO2 (CVO2, HPVO2) of 12.49+/-0.06 microL/h/mg in shams was significantly less than the combined VO2 of 15.90+/-0.59 microL/h/mg at 30 min post FPI (p<0.001). The maximal CVO2 of 19.49+/-1.10 microL/h/mg and the maximal HPVO2 of 15.98+/-0.99 microL/h/mg were both obtained from the ipsilateral side of the injury. Whereas the contralateral cortical value for injured brains was not significantly different from that of the shams, both ipsilateral and contralateral hippocampal values were significantly greater than that of the shams in response to injury (p<0.05). By 6 h postinjury, the combined VO2 had dropped to 10.01+/-0.84 microL/h/mg but was not significantly lower than the sham values. The data indicate that normal CVO2 is greater than normal HPVO2. The FPI produces significant increases in both CVO2 and HPVO2. Also, while the immediate increase in CVO2 appears to be injury-site dependent, that is, regional, the increase in HPVO2 appears to be global.