79 resultados para Cone Topography

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine (1) the optimal sites for mini-implant placement in the maxilla and the mandible based on dimensional mapping of the interradicular spaces and cortical bone thickness and (2) The effect of age and sex on the studied anatomic measurements. MATERIAL AND METHODS: The cone beam computed tomography images of 100 patients (46 males, 54 females) divided into two age groups (13-18 years), and (19-27 years) were used. The following interradicular measurements were performed: (1) Buccolingual bone thickness; (2) Mesiodistal spaces both buccally and palatally/lingually; and (3) Buccal and palatal/lingual cortical thicknesses. RESULTS: In the maxilla, the highest buccolingual thickness existed between first and second molars; the highest mesiodistal buccal/palatal distances were between the second premolar and the first molar. The highest buccal cortical thickness was between the first and second premolars. The highest palatal cortical thickness was between central and lateral incisors. In the mandible, the highest buccolingual and buccal cortical thicknesses were between the first and second molars. The highest mesiodistal buccal distance was between the second premolar and the first molar. The highest mesiodistal lingual distance was between the first and second premolars. The highest lingual cortical thickness was between the canine and the first premolar. The males and the older age group had significantly higher buccolingual, buccal, and palatal cortical thicknesses at specific sites and levels in the maxilla and the mandible. CONCLUSIONS: A clinical guideline for optimal sites for mini-implant placement is suggested. Sex and age affected the anatomic measurements in certain areas in the maxilla and the mandible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the dimensions and anatomic characteristics of the nasopalatine canal and the corresponding buccal bone plate of the alveolar process, using limited cone-beam computed tomography (CBCT) imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interaction between differentiating neurons and the extracellular environment guides the establishment of cell polarity during nervous system development. Developing neurons read the physical properties of the local substrate in a contact-dependent manner and retrieve essential guidance cues. In previous works we demonstrated that PC12 cell interaction with nanogratings (alternating lines of ridges and grooves of submicron size) promotes bipolarity and alignment to the substrate topography. Here, we investigate the role of focal adhesions, cell contractility, and actin dynamics in this process. Exploiting nanoimprint lithography techniques and a cyclic olefin copolymer, we engineered biocompatible nanostructured substrates designed for high-resolution live-cell microscopy. Our results reveal that neuronal polarization and contact guidance are based on a geometrical constraint of focal adhesions resulting in an angular modulation of their maturation and persistence. We report on ROCK1/2-myosin-II pathway activity and demonstrate that ROCK-mediated contractility contributes to polarity selection during neuronal differentiation. Importantly, the selection process confined the generation of actin-supported membrane protrusions and the initiation of new neurites at the poles. Maintenance of the established polarity was independent from NGF stimulation. Altogether our results imply that focal adhesions and cell contractility stably link the topographical configuration of the extracellular environment to a corresponding neuronal polarity state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the frequency of incidental maxillary sinus findings using cone-beam computed tomography (CBCT) images made for orthodontic purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this pilot investigation was to evaluate the utility and precision of already existing limited cone-beam computed tomography (CBCT) scans in measuring the endodontic working length, and to compare it with standard clinical procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess retrospectively the frequency and location of mandibular lingual foramina and their bony canals with limited cone-beam computed tomography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this retrospective radiographic study was to analyze the thickness of the facial bone wall at teeth in the anterior maxilla based on cone beam computed tomography (CBCT) images, since this anatomical structure is important for the selection of an appropriate treatment approach in patients undergoing postextraction implant placement. A total of 125 CBCT scans met the inclusion criteria, resulting in a sample size of 498 teeth. The thickness of the facial bone wall in the respective sagittal scans was measured perpendicular to the long axis of the tooth at two locations: at the crest level (4 mm apical to the cementoenamel junction; MP1) and at the middle of the root (MP2). No existing bone wall was found in 25.7% of all teeth at MP1 and in 10.0% at MP2. The majority of the examined teeth exhibited a thin facial bone wall (< 1 mm; 62.9% at MP1, 80.1% at MP2). A thick bone wall (? 1 mm) was found in only 11.4% of all examined teeth at MP1 and 9.8% at MP2. There was a statistically significant decrease in facial bone wall thickness from the first premolars to the central incisors. The facial bone wall in the crestal area of teeth in the anterior maxilla was either missing or thin in roughly 90.0% of patients. Both a missing and thin facial wall require simultaneous contour augmentation at implant placement because of the well-documented bone resorption that occurs at a thin facial bone wall following tooth extraction. Consequently, radiographic analysis of the facial bone wall using CBCT prior to extraction is recommended for selection of the appropriate treatment approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the dimensions of the Schneiderian membrane using limited cone beam computed tomography (CBCT) in individuals referred for dental implant surgery, and to determine factors influencing the mucosal thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluates the dimensions of nasopalatine duct cysts (NPDCs) and the involvement of neighboring anatomical structures using standardized limited cone beam computed tomography (CBCT) and a possible correlation to the patient's age, gender, preoperative symptoms, and postsurgical complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the detectability and dimensions of periapical lesions, the relationship of the mandibular canal to the roots of the respective teeth, and the dimension of the buccal bone by using limited cone-beam computed tomography (CBCT) in comparison to conventional periapical (PA) radiographs for evaluation of mandibular molars before apical surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to study the source characteristics of a clinical kilo-voltage cone beam CT unit and to develop and validate a virtual source model that could be used for treatment planning purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Economic theory distinguishes two concepts of utility: decision utility, objectively quantifiable by choices, and experienced utility, referring to the satisfaction by an obtainment. To date, experienced utility is typically measured with subjective ratings. This study intended to quantify experienced utility by global levels of neuronal activity. Neuronal activity was measured by means of electroencephalographic (EEG) responses to gain and omission of graded monetary rewards at the level of the EEG topography in human subjects. A novel analysis approach allowed approximating psychophysiological value functions for the experienced utility of monetary rewards. In addition, we identified the time windows of the event-related potentials (ERP) and the respective intracortical sources, in which variations in neuronal activity were significantly related to the value or valence of outcomes. Results indicate that value functions of experienced utility and regret disproportionally increase with monetary value, and thus contradict the compressing value functions of decision utility. The temporal pattern of outcome evaluation suggests an initial (∼250 ms) coarse evaluation regarding the valence, concurrent with a finer-grained evaluation of the value of gained rewards, whereas the evaluation of the value of omitted rewards emerges later. We hypothesize that this temporal double dissociation is explained by reward prediction errors. Finally, a late, yet unreported, reward-sensitive ERP topography (∼500 ms) was identified. The sources of these topographical covariations are estimated in the ventromedial prefrontal cortex, the medial frontal gyrus, the anterior and posterior cingulate cortex and the hippocampus/amygdala. The results provide important new evidence regarding “how,” “when,” and “where” the brain evaluates outcomes with different hedonic impact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a reliable microfabrication process for a combined atomic force microscopy (AFM) and scanning electrochemical microscopy (SECM) measurement tool. Integrated cone-shaped sensors with boron doped diamond (BDD) or gold (Au) electrodes were fabricated from commercially available AFM probes. The sensor formation process is based on mature semiconductor processing techniques, including focused ion beam (FIB) machining, and highly selective reactive ion etching (RIE). The fabrication approach preserves the geometry of the original AFM tips resulting in well reproducible nanoscaled sensors. The feasibility and functionality of the fully featured tips are demonstrated by cyclic voltammetry, showing good agreement between the measured and calculated currents of the cone-shaped AFM-SECM electrodes.