13 resultados para Condition-based Maintenance, Condition Monitoring, Prognostics, Reliability
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Worldwide, 700,000 infants are infected annually by HIV-1, most of them in resource-limited settings. Care for these children requires simple, inexpensive tests. We have evaluated HIV-1 p24 antigen for antiretroviral treatment (ART) monitoring in children. p24 by boosted enzyme-linked immunosorbent assay of heated plasma and HIV-1 RNA were measured prospectively in 24 HIV-1-infected children receiving ART. p24 and HIV-1 RNA concentrations and their changes between consecutive visits were related to the respective CD4+ changes. Age at study entry was 7.6 years; follow-up was 47.2 months, yielding 18 visits at an interval of 2.8 months (medians). There were 399 complete visit data sets and 375 interval data sets. Controlling for variation between individuals, there was a positive relationship between concentrations of HIV-1 RNA and p24 (P < 0.0001). While controlling for initial CD4+ count, age, sex, days since start of ART, and days between visits, the relative change in CD4+ count between 2 successive visits was negatively related to the corresponding relative change in HIV-1 RNA (P = 0.009), but not to the initial HIV-1 RNA concentration (P = 0.94). Similarly, we found a negative relationship with the relative change in p24 over the interval (P < 0.0001), whereas the initial p24 concentration showed a trend (P = 0.08). Statistical support for the p24 model and the HIV-1 RNA model was similar. p24 may be an accurate low-cost alternative to monitor ART in pediatric HIV-1 infection.
Resumo:
Although there has been a significant decrease in caries prevalence in developed countries, the slower progression of dental caries requires methods capable of detecting and quantifying lesions at an early stage. The aim of this study was to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent 2095 laser fluorescence device [LF], DIAGNOdent 2190 pen [LFpen], and VistaProof fluorescence camera [FC]) in monitoring the progression of noncavitated caries-like lesions on smooth surfaces. Caries-like lesions were developed in 60 blocks of bovine enamel using a bacterial model of Streptococcus mutans and Lactobacillus acidophilus . Enamel blocks were evaluated by two independent examiners at baseline (phase I), after the first cariogenic challenge (eight days) (phase II), and after the second cariogenic challenge (a further eight days) (phase III) by two independent examiners using the LF, LFpen, and FC. Blocks were submitted to surface microhardness (SMH) and cross-sectional microhardness analyses. The intraclass correlation coefficient for intra- and interexaminer reproducibility ranged from 0.49 (FC) to 0.94 (LF/LFpen). SMH values decreased and fluorescence values increased significantly among the three phases. Higher values for sensitivity, specificity, and area under the receiver operating characteristic curve were observed for FC (phase II) and LFpen (phase III). A significant correlation was found between fluorescence values and SMH in all phases and integrated loss of surface hardness (ΔKHN) in phase III. In conclusion, fluorescence-based methods were effective in monitoring noncavitated caries-like lesions on smooth surfaces, with moderate correlation with SMH, allowing differentiation between sound and demineralized enamel.
Resumo:
We present a fluorescence-lifetime based method for monitoring cell and tissue activity in situ, during cell culturing and in the presence of a strong autofluorescence background. The miniature fiber-optic probes are easily incorporated in the tight space of a cell culture chamber or in an endoscope. As a first application we monitored the cytosolic calcium levels in porcine tracheal explant cultures using the Calcium Green-5N (CG5N) indicator. Despite the simplicity of the optical setup we are able to detect changes of calcium concentration as small as 2.5 nM, with a monitoring time resolution of less than 1 s.
Resumo:
OBJECTIVES Application of the recently developed optical method based on the monitoring of the specular reflection intensity to study the protective potential of the salivary pellicle layer against early enamel erosion. METHODS The erosion progression was compared between two treatment groups: enamel samples coated by the 15 h-in vitro-formed salivary pellicle layer (group P, n=90) and the non-coated enamel surfaces (control group C, n=90). Different severity of the erosive impact was modelled by the enamel incubation in 1% citric acid (pH=3.6) for 2, 4, 8, 10 or 15 min. Erosion quantification was performed by the optical method as well as by the microhardness and calcium release analyses. RESULTS Optical assessment of the erosion progression showed erosion inhibition by the in vitro salivary pellicle in short term acidic treatments (≤ 4 min) which was also confirmed by microhardness measurements proving significantly less (p<0.05) enamel softening in the group P at 2 and 4 min of erosion compared to the group C. SEM images demonstrated less etched enamel interfaces in the group P at short erosion durations as well. CONCLUSIONS Monitoring of the specular reflection intensity can be successfully applied to quantify early erosion progression in comparative studies. In vitro salivary pellicle (2h) provides erosion inhibition but only in short term acidic exposures. CLINICAL SIGNIFICANCE The proposed optical technique is a promising tool for the fast and non-invasive erosion quantification in clinical studies.
Resumo:
Due to the lack of exercise testing devices that can be employed in stroke patients with severe disability, the aim of this PhD research was to investigate the clinical feasibility of using a robotics-assisted tilt table (RATT) as a method for cardiopulmonary exercise testing (CPET) and exercise training in stroke patients. For this purpose, the RATT was augmented with force sensors, a visual feedback system and a work rate calculation algorithm. As the RATT had not been used previously for CPET, the first phase of this project focused on a feasibility study in 11 healthy able-bodied subjects. The results demonstrated substantial cardiopulmonary responses, no complications were found, and the method was deemed feasible. The second phase was to analyse validity and test-retest reliability of the primary CPET parameters obtained from the RATT in 18 healthy able-bodied subjects and to compare the outcomes to those obtained from standard exercise testing devices (a cycle ergometer and a treadmill). The results demonstrated that peak oxygen uptake (V'O2peak) and oxygen uptake at the submaximal exercise thresholds on the RATT were ̴20% lower than for the cycle ergometer and ̴30% lower than on the treadmill. A very high correlation was found between the RATT vs the cycle ergometer V'O2peak and the RATT vs the treadmill V'O2peak. Test-retest reliability of CPET parameters obtained from the RATT were similarly high to those for standard exercise testing devices. These findings suggested that the RATT is a valid and reliable device for CPET and that it has potential to be used in severely impaired patients. Thus, the third phase was to investigate using the RATT for CPET and exercise training in 8 severely disabled stroke patients. The method was technically implementable, well tolerated by the patients, and substantial cardiopulmonary responses were observed. Additionally, all patients could exercise at the recommended training intensity for 10 min bouts. Finally, an investigation of test-retest reliability and four-week changes in cardiopulmonary fitness was carried out in 17 stroke patients with various degrees of disability. Good to excellent test-retest reliability and repeatability were found for the main CPET variables. There was no significant difference in most CPET parameters over four weeks. In conclusion, based on the demonstrated validity, reliability and repeatability, the RATT was found to be a feasible and appropriate alternative exercise testing and training device for patients who have limitations for use of standard devices.
Resumo:
Gastroesophageal reflux disease (GERD) still remains the most common out- GI-related condition in the out-patient setting. While primary care physicians often use empiric trials with proton pump inhibitors (PPI trial) to diagnose GERD, often specialised tests are required to confirm or exclude gastroesophageal reflux causing esophageal or extraesophageal symptoms. The most commonly used procedures to diagnose GERD include: conventional (catheter based) pH monitoring, wireless esophageal pH monitoring (Bravo), bilirubin monitoring (Bilitec), and combined multichannel intraluminal impedance-pH monitoring (MII-pH). Each technique has strengths and limitations of which clinicians and investigators should be aware when deciding which one to choose.
Resumo:
Background Data on combination antiretroviral therapy (cART) in remote rural African regions is increasing. Methods We assessed prospectively initial cART in HIV-infected adults treated from 2005 to 2008 at St. Francis Designated District Hospital, Ifakara, Tanzania. Adherence was assisted by personal adherence supporters. We estimated risk factors of death or loss to follow-up by Cox regression during the first 12 months of cART. Results Overall, 1,463 individuals initiated cART, which was nevirapine-based in 84.6%. The median age was 40 years (IQR 34-47), 35.4% were males, 7.6% had proven tuberculosis. Median CD4 cell count was 131 cells/μl and 24.8% had WHO stage 4. Median CD4 cell count increased by 61 and 130 cells/μl after 6 and 12 months, respectively. 215 (14.7%) patients modified their treatment, mostly due to toxicity (56%), in particular polyneuropathy and anemia. Overall, 129 patients died (8.8%) and 189 (12.9%) were lost to follow-up. In a multivariate analysis, low CD4 cells at starting cART were associated with poorer survival and loss to follow-up (HR 1.77, 95% CI 1.15-2.75, p = 0.009; for CD4 <50 compared to >100 cells/μl). Higher weight was strongly associated with better survival (HR 0.63, 95% CI 0.51-0.76, p < 0.001 per 10 kg increase). Conclusions cART initiation at higher CD4 cell counts and better general health condition reduces HIV related mortality in a rural African setting. Efforts must be made to promote earlier HIV diagnosis to start cART timely. More research is needed to evaluate effective strategies to follow cART at a peripheral level with limited technical possibilities.
Resumo:
Gastro-oesophageal reflux disease (GERD) is a highly prevalent condition in Western countries leading to millions of outpatient visits per year. GERD symptoms including heartburn, regurgitation and chest pain are caused by reflux of gastric content in the oesophagus even in the absence of endoscopically visible mucosal lesions. Several procedures are used to identify gastro-oesophageal reflux, the clinically widely used are: conventional (catheter-based) pH monitoring, wireless oesophageal pH monitoring (Bravo), bilirubin monitoring (Bilitec), and combined multichannel intraluminal impedance-pH monitoring (MII-pH). Each technique has strengths and limitations of which clinicians and investigators should be aware when deciding which to choose in a particular patient. Important is the ability to quantify gastro-oesophageal reflux and evaluate the relationship between symptoms and reflux episodes. The present review summarises the technical aspects in performing and interpreting esophageal reflux monitoring procedures.
Resumo:
Human-induced forest modification can alter parasite-host interactions and might change the persistence of host populations. We captured individuals of two widespread European passerines (Fringilla coelebs and Sylvia atricapilla) in southwestern Germany to disentangle the associations of forest types and parasitism by haemosporidian parasites on the body condition of birds. We compared parasite prevalence and parasite intensity, fluctuating asymmetries, leukocyte numbers, and the heterophil to lymphocyte ratio (H/L-ratio) among individuals from beech, mixed-deciduous and spruce forest stands. Based on the biology of bird species, we expected to find fewer infected individuals in beech or mixed-deciduous than in spruce forest stands. We found the highest parasite prevalence and intensity in beech forests for F. coelebs. Although, we found the highest prevalence in spruce forests for S. atricapilla, the highest intensity was detected in beech forests, partially supporting our hypothesis. Other body condition or health status metrics, such as the heterophil to lymphocyte ratio (H/L-ratio), revealed only slight differences between bird populations inhabiting the three different forest types, with the highest values in spruce for F. coelebs and in mixed-deciduous forests for S. atricapilla. A comparison of parasitized versus non-parasitized individuals suggests that parasite infection increased the immune response of a bird, which was detectable as high H/L-ratio. Higher infections with blood parasites for S. atricapilla in spruce forest indicate that this forest type might be a less suitable habitat than beech and mixed-deciduous forests, whereas beech forests seem to be a suboptimal habitat regarding parasitism for F. coelebs.
Resumo:
BACKGROUND AND OBJECTIVES Reliability is an essential condition for using quantitative sensory tests (QSTs) in research and clinical practice, but information on reliability in patients with chronic pain is sparse. The aim of this study was to evaluate the reliability of different QST in patients with chronic low back pain. METHODS Eighty-nine patients with chronic low back pain participated in 2 identical experimental sessions, separated by at least 7 days. The following parameters were recorded: pressure pain detection and tolerance thresholds at the toe, electrical pain thresholds to single and repeated stimulation, heat pain detection and tolerance thresholds at the arm and leg, cold pain detection threshold at the arm and leg, and conditioned pain modulation using the cold pressor test.Reliability was analyzed using the coefficient of variation, the coefficient of repeatability, and the intraclass correlation coefficient. It was judged as acceptable or not based primarily on the analysis of the coefficient of repeatability. RESULTS The reliability of most tests was acceptable. Exceptions were cold pain detection thresholds at the leg and arm. CONCLUSIONS Most QST measurements have acceptable reliability in patients with chronic low back pain.