5 resultados para Condition monitoring

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Along a downstream stretch of River Mure , Romania, adult males of two feral fish species, European chub (Leuciscus cephalus) and sneep (Chondrostoma nasus) were sampled at four sites with different levels of contamination. Fish were analysed for the biochemical markers hsp70 (in liver and gills) and hepatic EROD activity, as well as several biometrical parameters (age, length, wet weight, condition factor). None of the biochemical markers correlated with any biometrical parameter, thus biomarker reactions were related to site-specific criteria. While the hepatic hsp70 level did not differ among the sites, significant elevation of the hsp70 level in the gills revealed proteotoxic damage in chub at the most upstream site, where we recorded the highest heavy metal contamination of the investigated stretch, and in both chub and sneep at the site right downstream of the city of Arad. In both species, significantly elevated hepatic EROD activity downstream of Arad indicated that fish from these sites are also exposed to organic chemicals. The results were indicative of impaired fish health at least at three of the four investigated sites. The approach to relate biomarker responses to analytical data on pollution was shown to fit well the recent EU demands on further enhanced efforts in the monitoring of Romanian water quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gastro-oesophageal reflux disease (GERD) is a highly prevalent condition in Western countries leading to millions of outpatient visits per year. GERD symptoms including heartburn, regurgitation and chest pain are caused by reflux of gastric content in the oesophagus even in the absence of endoscopically visible mucosal lesions. Several procedures are used to identify gastro-oesophageal reflux, the clinically widely used are: conventional (catheter-based) pH monitoring, wireless oesophageal pH monitoring (Bravo), bilirubin monitoring (Bilitec), and combined multichannel intraluminal impedance-pH monitoring (MII-pH). Each technique has strengths and limitations of which clinicians and investigators should be aware when deciding which to choose in a particular patient. Important is the ability to quantify gastro-oesophageal reflux and evaluate the relationship between symptoms and reflux episodes. The present review summarises the technical aspects in performing and interpreting esophageal reflux monitoring procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Erroneous answers in studies on the misinformation effect (ME) can be reduced in different ways. In some studies, ME was reduced by SM questions, warnings, or a low credibility of the source of post-event information (PEI). Results are inconsistent, however. Of course, a participant can deliberately decide to refrain from reporting a critical item only when the difference between the original event and the PEI is distinguishable in principle. We were interested in the question to what extent the influence of erroneous information on a central aspect of the original event can be reduced by different means applied singly or in combination. Method. With a 2 (credibility; high vs. low) x 2 (warning; present vs. absent) between subjects design and an additional control group that received neither misinformation nor a warning (N = 116), we examined the above-mentioned factors’ influence on the ME. Participants viewed a short video of a robbery. The critical item suggested in the PEI was that the victim was given a kick by the perpetrator (which he was actually not). The memory test consisted of a two-forced-choice recognition test followed by a SM test. Results. To our surprise, neither a main effect of erroneous PEI nor a main effect of credibility was found. The error rates for the critical item in the control group (50%) as well as in the high (65%) and low (52%) credibility condition without warning did not significantly differ. A warning about possible misleading information in the PEI significantly reduced the influence of misinformation in both credibility conditions by 32-37%. Using a SM question significantly reduced the error rate too, but only in the high credibility no warning condition. Conclusion and Future Research. Our results show that, contrary to a warning or the use of a SM question, low source credibility did not reduce the ME. The most striking finding was, however, the absence of a main effect of erroneous PEI. Due to the high error rate in the control group, we suspect that the wrong answers might have been caused either by the response format (recognition test) or by autosuggestion possibly promoted by the high schema-consistency of the critical item. First results of a post-study in which we used open-ended questions before the recognition test support the former assumption. Results of a replication of this study using open-ended questions prior to the recognition test will be available by June.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Although it seems plausible that sports performance relies on high-acuity foveal vision, it could be empirically shown that myoptic blur (up to +2 diopters) does not harm performance in sport tasks that require foveal information pick-up like golf putting (Bulson, Ciuffreda, & Hung, 2008). How myoptic blur affects peripheral performance is yet unknown. Attention might be less needed for processing visual cues foveally and lead to better performance because peripheral cues are better processed as a function of reduced foveal vision, which will be tested in the current experiment. Methods: 18 sport science students with self-reported myopia volunteered as participants, all of them regularly wearing contact lenses. Exclusion criteria comprised visual correction other than myopic, correction of astigmatism and use of contact lenses out of Swiss delivery area. For each of the participants, three pairs of additional contact lenses (besides their regular lenses; used in the “plano” condition) were manufactured with an individual overcorrection to a retinal defocus of +1 to +3 diopters (referred to as “+1.00 D”, “+2.00 D”, and “+3.00 D” condition, respectively). Gaze data were acquired while participants had to perform a multiple object tracking (MOT) task that required to track 4 out of 10 moving stimuli. In addition, in 66.7 % of all trials, one of the 4 targets suddenly stopped during the motion phase for a period of 0.5 s. Stimuli moved in front of a picture of a sports hall to allow for foveal processing. Due to the directional hypotheses, the level of significance for one-tailed tests on differences was set at α = .05 and posteriori effect sizes were computed as partial eta squares (ηρ2). Results: Due to problems with the gaze-data collection, 3 participants had to be excluded from further analyses. The expectation of a centroid strategy was confirmed because gaze was closer to the centroid than the target (all p < .01). In comparison to the plano baseline, participants more often recalled all 4 targets under defocus conditions, F(1,14) = 26.13, p < .01, ηρ2 = .65. The three defocus conditions differed significantly, F(2,28) = 2.56, p = .05, ηρ2 = .16, with a higher accuracy as a function of a defocus increase and significant contrasts between conditions +1.00 D and +2.00 D (p = .03) and +1.00 D and +3.00 D (p = .03). For stop trials, significant differences could neither be found between plano baseline and defocus conditions, F(1,14) = .19, p = .67, ηρ2 = .01, nor between the three defocus conditions, F(2,28) = 1.09, p = .18, ηρ2 = .07. Participants reacted faster in “4 correct+button” trials under defocus than under plano-baseline conditions, F(1,14) = 10.77, p < .01, ηρ2 = .44. The defocus conditions differed significantly, F(2,28) = 6.16, p < .01, ηρ2 = .31, with shorter response times as a function of a defocus increase and significant contrasts between +1.00 D and +2.00 D (p = .01) and +1.00 D and +3.00 D (p < .01). Discussion: The results show that gaze behaviour in MOT is not affected to a relevant degree by a visual overcorrection up to +3 diopters. Hence, it can be taken for granted that peripheral event detection was investigated in the present study. This overcorrection, however, does not harm the capability to peripherally track objects. Moreover, if an event has to be detected peripherally, neither response accuracy nor response time is negatively affected. Findings could claim considerable relevance for all sport situations in which peripheral vision is required which now needs applied studies on this topic. References: Bulson, R. C., Ciuffreda, K. J., & Hung, G. K. (2008). The effect of retinal defocus on golf putting. Ophthalmic and Physiological Optics, 28, 334-344.