4 resultados para Composites carbon fiber race car mainplane wing Dallara design CAD lamination lay-up

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the bone formation capability of polyetheretherketone (PEEK) and carbon fiber-reinforced PEEK (CFR-PEEK) implants coated with different titanium and hydroxyapatite plasma-sprayed layers after 2 and 12 weeks. Methods: In six sheep 108 implants were placed in the pelvis. Altogether six different surface modifications were tested. After 2 and 12 weeks, n = 3 implants per group were examined histologically and n = 6 implants per group were tested by a pull-out test. Results: Biomechanically (p = 0.001) as well as histologically (p > 0.05) surface coating of PEEK/CFR-PEEK led to an increase of osseointegration from 2 to 12 weeks. After 12 weeks, coated implants demonstrated significant (p < 0.001) higher pull-out values in comparison to uncoated implants. Overall, the double coating (titanium bond layer and hydroxyapatite top layer) showed the most favorable results after 2 and 12 weeks. Conclusions: Plasma-sprayed titanium and hydroxyapatite coatings on PEEK or CFR-PEEK demonstrated a significant improvement of osseointegration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To investigate effects of interictal epileptic activity (IEA) and antiepileptic drugs (AEDs) on reactivity and aspects of the fitness to drive for epilepsy patients. METHODS Forty-six adult patients with demonstration of focal or generalized bursts of IEA in electroencephalography (EEG) readings within 1 year prior to inclusion irrespective of medication performed a car driving computer test or a single light flash test (39 patients performed both). Reaction times (RTs), virtual crashes, or lapses (RT ≥ 1 s in the car or flash test) were measured in an IEA burst-triggered fashion during IEA and compared with RT-measurements during unremarkable EEG findings in the same session. RESULTS IEA prolonged RTs both in the flash and car test (p < 0.001) in individual patients up to 200 ms. Generalized IEA with spike/waves (s/w) had the largest effect on RT prolongation (p < 0.001, both tests), whereas mean RT during normal EEG, age, gender, and number of AEDs had no effect. The car test was better than the flash test in detecting RT prolongations (p = 0.030). IEA increased crashes/lapses >26% in sessions with generalized IEA with s/w. The frequency of IEA-associated RT >1 s exceeded predictions (p < 0.001) based on simple RT shift, suggesting functional impairment beyond progressive RT prolongation by IEA. The number of AEDs correlated with prolonged RTs during normal EEG (p < 0.021) but not with IEA-associated RT prolongation or crashes/lapses. SIGNIFICANCE IEA prolonged RTs to varying extents, dependent on IEA type. IEA-associated RTs >1 s were more frequent than predicted, suggesting beginning cerebral decompensation of visual stimulus processing. AEDs somewhat reduced psychomotor speed, but it was mainly the IEA that contributed to an excess of virtual accidents.