49 resultados para Compliance aid
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.
Resumo:
PURPOSE: The mandibular implant overdenture is a popular treatment modality and is well documented in the literature. Follow-up studies with a long observation period are difficult to perform due to the increasing age of patients. The present data summarize a long-term clinical observation of patients with implant overdentures. MATERIALS AND METHODS: Between 1984 and 1997, edentulous patients were consecutively admitted for treatment with an implant overdenture. The dentures were connected to the implants by means of bars or ball anchors. Regular maintenance was provided with at least one or two scheduled visits per year. Recall attendance and reasons for dropout were analyzed based on the specific history of the patient. Denture maintenance service, relining, repair, and fabrication of new dentures were identified, and complications with the retention devices specified separately. RESULTS: In the time period from 1984 to 2008, 147 patients with a total of 314 implants had completed a follow-up period of >10 years. One hundred one patients were still available in 2008, while 46 patients were not reexamined for various reasons. Compliance was high, with a regular recall attendance of >90%. More than 80% of dentures remained in continuous service. Although major prosthetic maintenance was rather low in relation to the long observation period, visits to a dental hygienist and dentist resulted in an annual visit rate of 1.5 and 2.4, respectively. If new dentures became necessary, these were made in student courses, which increased the treatment time and number of appointments needed. Complications with the retention devices consisted mostly of the mounting of new female retainers, the repair of bars, and the changing of ball anchors. The average number of events and the rate of prosthetic service with ball anchors were significantly higher than those with bars. Twenty-two patients changed from ball anchors to bars; 9 patients switched from a clip bar to a rigid U-shaped bar. CONCLUSIONS: This long-term follow-up study demonstrates that implant overdentures are a favorable solution for edentulous patients with regular maintenance. In spite of specific circumstances in an aging population, it is possible to provide long-term care, resulting in a good prognosis and low risk for this treatment modality. For various reasons the dropout rate can be considerable in elderly patients and prosthetic service must be provided regularly.
Resumo:
The Oxford Programme for Immunomodulatory Immunoglobulin Therapy has been operating since 1992 at Oxford Radcliffe Hospitals in the UK. Initially, this program was set up for patients with multifocal motor neuropathy or chronic inflammatory demyelinating poly-neuropathy to receive reduced doses of intravenous immunoglobulin (IVIG) in clinic on a regular basis (usually every 3 weeks). The program then rapidly expanded to include self-infusion at home, which monitoring showed to be safe and effective. It has been since extended to the treatment of other autoimmune diseases in which IVIG has been shown to be efficacious.
Resumo:
The cytidine deaminase AID hypermutates immunoglobulin genes but can also target oncogenes, leading to tumorigenesis. The extent of AID's promiscuity and its predilection for immunoglobulin genes are unknown. We report here that AID interacted broadly with promoter-proximal sequences associated with stalled polymerases and chromatin-activating marks. In contrast, genomic occupancy of replication protein A (RPA), an AID cofactor, was restricted to immunoglobulin genes. The recruitment of RPA to the immunoglobulin loci was facilitated by phosphorylation of AID at Ser38 and Thr140. We propose that stalled polymerases recruit AID, thereby resulting in low frequencies of hypermutation across the B cell genome. Efficient hypermutation and switch recombination required AID phosphorylation and correlated with recruitment of RPA. Our findings provide a rationale for the oncogenic role of AID in B cell malignancy.
Resumo:
Despite a growing number of identified genetic causes of monogenetic disorders, early molecular testing is rarely applied in daily nephrologic practice. In selected cases and to answer specific questions, molecular testing however can be helpful for the specialist. The future significance of genetic testing most likely lies in the area of individual risk profiling for polygenetic disorders. The basis for this testing however has yet to be established.
Resumo:
This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation.
Resumo:
To document the rate of self-reported compliance and glaucoma-related knowledge in Swiss patients and to identify risk factors for their poor compliance. This was an observational study, including a total of 200 consecutive patients already under glaucoma medication in two Swiss tertiary glaucoma clinics (Geneva and Bern). Personal characteristics, presence of systemic disease, compliance with glaucoma medication, attitude to the ophthalmologist, and glaucoma-related attitudes were ascertained by means of a predetermined questionnaire with 40 questions. Patients were subsequently assessed for the ability to correctly instil placebo eye drops. Non-compliance with glaucoma medication was defined as omitting more than two doses a week as reported by the patient. Logistic regression was used to evaluate how patient characteristics and knowledge about the disease were related to compliance. Overall, 81% (n = 162) of patients reported to be compliant. Forgetfulness was the most frequently cited reason for non-compliance with dosing regimen (63%). Although 90.5% (n = 181) of patients believed glaucoma medication to be efficient, only 28% (n = 56) could correctly define glaucoma. Factors positively associated with compliance were 'knowledge of glaucoma' [adjusted odds ratio (OR) 4.77 (95% CI 1.36-16.70)] and 'getting help for administration of drops' [OR 2.95 (1.25-6.94)]. These findings indicate that despite the comparatively high compliance rate among glaucoma patients, knowledge of glaucoma remains poor in long-term glaucoma sufferers. Improving knowledge about the disease is important since it is positively associated with compliance in our study.
Resumo:
A systematic literature review was conducted to assess the effectiveness of, compliance with, and critical factors for the implementation of safety checklists in surgery.
Resumo:
PURPOSE : For the facilitation of minimally invasive robotically performed direct cochlea access (DCA) procedure, a surgical planning tool which enables the surgeon to define landmarks for patient-to-image registration, identify the necessary anatomical structures and define a safe DCA trajectory using patient image data (typically computed tomography (CT) or cone beam CT) is required. To this end, a dedicated end-to-end software planning system for the planning of DCA procedures that addresses current deficiencies has been developed. METHODS : Efficient and robust anatomical segmentation is achieved through the implementation of semiautomatic algorithms; high-accuracy patient-to-image registration is achieved via an automated model-based fiducial detection algorithm and functionality for the interactive definition of a safe drilling trajectory based on case-specific drill positioning uncertainty calculations was developed. RESULTS : The accuracy and safety of the presented software tool were validated during the conduction of eight DCA procedures performed on cadaver heads. The plan for each ear was completed in less than 20 min, and no damage to vital structures occurred during the procedures. The integrated fiducial detection functionality enabled final positioning accuracies of [Formula: see text] mm. CONCLUSIONS : Results of this study demonstrated that the proposed software system could aid in the safe planning of a DCA tunnel within an acceptable time.