32 resultados para Coloured Organics

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synaesthesia is a heterogeneous phenomenon, even when considering one particular sub-type. The purpose of this study was to design a reliable and valid questionnaire for grapheme-colour synaesthesia that captures this heterogeneity. By the means of a large sample of 628 synaesthetes and a factor analysis, we created the Coloured Letters and Numbers (CLaN) questionnaire with 16 items loading on 4 different factors (i.e., localisation, automaticity/attention, deliberate use, and longitudinal changes). These factors were externally validated with tests which are widely used in the field of synaesthesia research. The questionnaire showed good test–retest reliability and construct validity (i.e., internally and externally). Our findings are discussed in the light of current theories and new ideas in synaesthesia research. More generally, the questionnaire is a useful tool which can be widely used in synaesthesia research to reveal the influence of individual differences on various performance measures and will be useful in generating new hypotheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A search for pair-produced massive coloured scalar particles decaying to a four-jet final state is performed by the ATLAS experiment at the LHC in proton-proton collisions at root s = 7 TeV. The analysed data sample corresponds to an integrated luminosity of 4.6 fb(-1). No deviation from the Standard Model is observed in the invariant mass spectrum of the two-jet pairs. A limit on the scalar gluon pair production cross section of 70 pb (10 pb) is obtained at the 95 % confidence level for a scalar gluon mass of 150 GeV (350 GeV). Interpreting these results as mass limits on scalar gluons, masses ranging from 150 GeV to 287 GeV are excluded at the 95 % confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Chewing efficiency may be evaluated using cohesive specimen, especially in elderly or dysphagic patients. The aim of this study was to evaluate three two-coloured chewing gums for a colour-mixing ability test and to validate a new purpose built software (ViewGum©). METHODS Dentate participants (dentate-group) and edentulous patients with mandibular two-implant overdentures (IOD-group) were recruited. First, the dentate-group chewed three different types of two-coloured gum (gum1-gum3) for 5, 10, 20, 30 and 50 chewing cycles. Subsequently the number of chewing cycles with the highest intra- and inter-rater agreement was determined visually by applying a scale (SA) and opto-electronically (ViewGum©, Bland-Altman analysis). The ViewGum© software determines semi-automatically the variance of hue (VOH); inadequate mixing presents with larger VOH than complete mixing. Secondly, the dentate-group and the IOD-group were compared. RESULTS The dentate-group comprised 20 participants (10 female, 30.3±6.7 years); the IOD-group 15 participants (10 female, 74.6±8.3 years). Intra-rater and inter-rater agreement (SA) was very high at 20 chewing cycles (95.00-98.75%). Gums 1-3 showed different colour-mixing characteristics as a function of chewing cycles, gum1 showed a logarithmic association; gum2 and gum3 demonstrated more linear behaviours. However, the number of chewing cycles could be predicted in all specimens from VOH (all p<0.0001, mixed linear regression models). Both analyses proved discriminative to the dental state. CONCLUSION ViewGum© proved to be a reliable and discriminative tool to opto-electronically assess chewing efficiency, given an elastic specimen is chewed for 20 cycles and could be recommended for the evaluation of chewing efficiency in a clinical and research setting. CLINICAL SIGNIFICANCE Chewing is a complex function of the oro-facial structures and the central nervous system. The application of the proposed assessments of the chewing function in geriatrics or special care dentistry could help visualising oro-functional or dental comorbidities in dysphagic patients or those suffering from protein-energy malnutrition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Local anaesthetic blocks of the greater occipital nerve (GON) are frequently performed in different types of headache, but no selective approaches exist. Our cadaver study compares the sonographic visibility of the nerve and the accuracy and specificity of ultrasound-guided injections at two different sites. METHODS: After sonographic measurements in 10 embalmed cadavers, 20 ultrasound-guided injections of the GON were performed with 0.1 ml of dye at the classical site (superior nuchal line) followed by 20 at a newly described site more proximal (C2, superficial to the obliquus capitis inferior muscle). The spread of dye and coloration of nerve were evaluated by dissection. RESULTS: The median sonographic diameter of the GON was 4.2 x 1.4 mm at the classical and 4.0 x 1.8 mm at the new site. The nerves were found at a median depth of 8 and 17.5 mm, respectively. In 16 of 20 in the classical approach and 20 of 20 in the new approach, the nerve was successfully coloured with the dye. This corresponds to a block success rate of 80% (95% confidence interval: 58-93%) vs 100% (95% confidence interval: 86-100%), which is statistically significant (McNemar's test, P=0.002). CONCLUSIONS: Our findings confirm that the GON can be visualized using ultrasound both at the level of the superior nuchal line and C2. This newly described approach superficial to the obliquus capitis inferior muscle has a higher success rate and should allow a more precise blockade of the nerve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Humans perceive the content (gist) of a scene very rapidly within about 40 ms [Castelhano and Henderson, 2008 Journal of Experimental Psychology Human Perception and Performance 43(3) 660-675]. It has also been demonstrated that colours contribute to the perception of the gist of a scene if the colours are diagnostic for the distinction of scenes (Oliva and Schyns, 2000 Cognitive Psychology 41 176-210). We presented 320 coloured photographs of 2 diagnostic (mountains and coasts) and 2 nondiagnostic colour scenes (cities and rooms), 80 per category, in a masking paradigm. The mask consisted of randomly distributed colour patches. SOA was varied between 20 and 80 ms, in steps of 20 ms and subjects had to indicate the gist of the scene (4AFC). A control condition without masking was also included. In line with previous results we have found that the gist of nondiagnostic coloured scenes is extracted within 40 ms. However, if colour comes into play, the extraction of the scene gist is prolonged by about 20 ms. A possible reason for this outcome might be that nondiagnostic colour scenes are identified by their luminance components which are processed faster than the colour information, which in turn mediates the identification of diagnostic colour scenes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper I investigate the vivid discussions among Muslim theologians and philosophers about the relationship of reason and religion from the 11th to the 14th centuries – which continue to be used as points of reference today. I argue that the idea of Islam as a religion which is in harmony with reason was one of the key postulates of the dominant thinkers of that period, regardless of their school of thought or their attitude towards literal or allegorical ways of understanding the Coran. In consequence, religion has been rationalized or even intellectualized to a high degree while philosophy in turn has been deeply coloured by religious images and concepts. Yet the understanding of religion as well as of reason and its instruments has been so heterogeneous that rationalization could bear very different, even conflicting meanings, thereby undermining the postulated harmony. In seven theses I foreground several striking similarities and differences between theologians and philosophers who diverge in their usage and understanding of reason as well as of the nature of religion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The KIT receptor protein-tyrosine kinase plays an important role during embryonic development. Activation of KIT is crucial for the development of various cell lineages such as melanoblasts, stem cells of the haematopoietic system, spermatogonia and intestinal cells of Cajal. In mice, many mutations in the Kit gene cause pigmentation disorders accompanied by pleiotropic effects on blood cells and male fertility. Previous work has demonstrated that dominant white Franches-Montagnes horses carry one copy of the KIT gene with the p.Y717X mutation. The targeted breeding of white horses would be ethically questionable if white horses were known to suffer from anaemia or leukopenia. The present study demonstrates that no statistically significant differences in peripheral blood parameters are detectable between dominant white and solid-coloured Franches-Montagnes horses. The data indicate that KIT mutations may have different effects in mice, pigs, and horses. The KIT p.Y717X mutation does not have a major negative effect on the haematopoietic system of dominant white horses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We recently mapped the belt mutation in Brown Swiss cattle to a 922 kb interval on BTA3. In this study, we analysed two additional cattle breeds with the belted phenotype: Galloway and Dutch Belted (Lakenvelder). By genotyping microsatellites in solid-coloured and belted Galloways, we confirmed that the belt mutation in Galloways is strongly associated with the same chromosomal locus as in Brown Swiss cattle. Subsequently, we analysed 36 SNPs in the belt interval in three breeds. We identified a single belt-associated haplotype for each of the analysed breeds. The three breed-specific belt haplotypes share alleles in four blocks. Three of these blocks comprise only one single or two consecutive markers, while the largest shared haplotype block encompasses nine consecutive SNPs in a 336 kb interval. The large shared haplotype across divergent breeds suggests a common mutation for the belt phenotype in all three breeds. We identified a potential candidate gene within this interval coding for the developmental transcription factor HES6. We re-sequenced the complete HES6 coding sequence in belted and solid-coloured cattle but did not find belt-associated polymorphisms. In conclusion, our data provide strong evidence in favour of a common founder for the belt phenotype in different cattle breeds and have resulted in an improved fine-mapping of the causative mutation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Ilioinguinal and iliohypogastric nerve blocks may be used in the diagnosis of chronic groin pain or for analgesia for hernia repair. This study describes a new ultrasound-guided approach to these nerves and determines its accuracy using anatomical dissection control. METHODS: After having tested the new method in a pilot cadaver, 10 additional embalmed cadavers were used to perform 37 ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve. After injection of 0.1 ml of dye the cadavers were dissected to evaluate needle position and colouring of the nerves. RESULTS: Thirty-three of the thirty-seven needle tips were located at the exact target point, in or directly at the ilioinguinal or iliohypogastric nerve. In all these cases the targeted nerve was coloured entirely. In two of the remaining four cases parts of the nerves were coloured. This corresponds to a simulated block success rate of 95%. In contrast to the standard 'blind' techniques of inguinal nerve blocks we visualized and targeted the nerves 5 cm cranial and posterior to the anterior superior iliac spine. The median diameters of the nerves measured by ultrasound were: ilioinguinal 3.0x1.6 mm, and iliohypogastric 2.9x1.6 mm. The median distance of the ilioinguinal nerve to the iliac bone was 6.0 mm and the distance between the two nerves was 10.4 mm. CONCLUSIONS: The anatomical dissections confirmed that our new ultrasound-guided approach to the ilioinguinal and iliohypogastric nerve is accurate. Ultrasound could become an attractive alternative to the 'blind' standard techniques of ilioinguinal and iliohypogastric nerve block in pain medicine and anaesthetic practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Accompanying the patient recruitment within the "Scleral buckling versus primary vitrectomy in rhegmatogenous retinal detachment multicentre trial (SPR)", all patients with primary rhegmatogenous retinal detachment (RRD) had to be documented in a detailed recruitment list. The main goal of this analysis was to estimate the prevalence of "medium-severe" RRD (SPR Study eligible) as defined by the SPR Study inclusion criteria. In addition, the detailed anatomical situation of medium-severe RRD is investigated. METHODS: SPR Study recruitment was evaluated via a standardised questionnaire, which contained a coloured fundus drawing and information regarding possible reasons for exclusion from the SPR Study in each case. A team of three experienced vitreoretinal surgeons evaluated all fundus drawings from a 1-year period. The review led to a decision on SPR Study eligibility on the pure basis of anatomical assessment. The main outcome measures were assessment of feasible inclusion into the SPR Study by the evaluation team based on the fundus drawing and anatomical details. RESULTS: A total of 1,115 patients with RRD from 13 European centres were prospectively enrolled in the year 2000. The quality of the drawings sufficed for assessment in 1,107 cases (99.3%). Three hundred and twelve fundus drawings (28.2%) met the anatomic inclusion criteria of the SPR Study. RRD of medium severity is characterised by an average number of 2.6 (SD 2.4) retinal breaks, 5.8 (SD 2.8) clock hours of detached retina, unclear hole situation in 15.1% of cases (n=47), attached macula in 42.9% (n=134), bullous detachment in 15.1% (n=47) and vitreous haemorrhage/opacity in 7.7% (n=24). CONCLUSIONS: In the recruitment lists of the SPR Study of the year 2000, RRD of medium severity was present in nearly one third of the patients with primary RRD. These findings emphasise the clinical relevance of the SPR Study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Non-invasive documentation methods such as surface scanning and radiological imaging are gaining in importance in the forensic field. These three-dimensional technologies provide digital 3D data, which are processed and handled in the computer. However, the sense of touch gets lost using the virtual approach. The haptic device enables the use of the sense of touch to handle and feel digital 3D data. The multifunctional application of a haptic device for forensic approaches is evaluated and illustrated in three different cases: the representation of bone fractures of the lower extremities, by traffic accidents, in a non-invasive manner; the comparison of bone injuries with the presumed injury-inflicting instrument; and in a gunshot case, the identification of the gun by the muzzle imprint, and the reconstruction of the holding position of the gun. The 3D models of the bones are generated from the Computed Tomography (CT) images. The 3D models of the exterior injuries, the injury-inflicting tools and the bone injuries, where a higher resolution is necessary, are created by the optical surface scan. The haptic device is used in combination with the software FreeForm Modelling Plus for touching the surface of the 3D models to feel the minute injuries and the surface of tools, to reposition displaced bone parts and to compare an injury-causing instrument with an injury. The repositioning of 3D models in a reconstruction is easier, faster and more precisely executed by means of using the sense of touch and with the user-friendly movement in the 3D space. For representation purposes, the fracture lines of bones are coloured. This work demonstrates that the haptic device is a suitable and efficient application in forensic science. The haptic device offers a new way in the handling of digital data in the virtual 3D space.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Perceptual-cognitive impairment after general anaesthesia may affect the ability to reliably report pain severity with the standard visual analog scale (VAS). To minimise these limitations, we developed 'PAULA the PAIN-METER' (PAULA): it has five coloured emoticon faces on the forefront, it is twice as long as a standard VAS scale, and patients use a slider to mark their pain experience. Forty-eight postoperative patients rated descriptive pain terms on PAULA and on a standard VAS immediately after admission and before discharge from the postanaesthesia care unit. Visual acuity was determined before both assessments. The values obtained with PAULA showed less variance than those obtained with the standard VAS, even at the first assessment, where only 23% of the patients had regained their visual acuity. Furthermore, the deviations of the absolute VAS values in individual patients for each descriptive pain term were significantly smaller with PAULA than with the standard VAS.