105 resultados para Clinical performance
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To compare the alterations in esthetic appearance and slot morphology/integrity of two main types of esthetic brackets caused after clinical use.
Resumo:
Purpose: The objective of this review was to systematically screen the literature for data related to the survival and complication rates observed with dental or implant double crown abutments and removable prostheses under functional loading for at least 3 years. Materials and Methods: A systematic review of the dental literature from January 1966 to December 2009 was performed in electronic databases (PubMed and Embase) as well as by an extensive hand search to investigate the clinical outcomes of double crown reconstructions. Results: From the total of 2412 titles retrieved from the search, 65 were selected for full-text review. Subsequently, 17 papers were included for data extraction. An estimation of the cumulative survival and complication rates was not feasible due to the lack of detailed information. Tooth survival rates for telescopic abutment teeth ranged from 82.5% to 96.5% after an observation period of 3.4 to 6 years, and for tooth-supported double crown retained dentures from 66.7% to 98.6% after an observation period of 6 to 10 years. The survival rates of implants were between 97.9% and 100% and for telescopic-retained removable dental prostheses with two mandibular implants, 100% after 3.0 and 10.4 years. The major biological complications affecting the tooth abutments were gingival inflammation, periodontal disease, and caries. The most frequent technical complications were loss of cementation and loss of facings. Conclusions: The main findings of this review are: (I) double crown tooth abutments and dentures demonstrated a wide range of survival rates. (II) Implant-supported mandibular overdentures demonstrated a favorable long-term prognosis. (III) A greater need for prosthetic maintenance is required for both tooth-supported and implant-supported reconstructions. (IV) Future areas of research would involve designing appropriate longitudinal studies for comparisons of survival and complication rates of different reconstruction designs.
Resumo:
PURPOSE: The aim of this study was to evaluate the 3-year success rates of wide-body implants with a regular- or wide-neck configuration and a sandblasted, large grit, acid-etched (SLA) surface. MATERIALS AND METHODS: A total of 151 implants were consecutively placed in posterior sites of 116 partially edentulous patients in a referral clinic at the School of Dental Medicine, University of Bern. All implants were restored with cemented crowns or fixed partial dentures after a healing period of 6 to 8 weeks (for implants placed without simultaneous bone augmentation) or 10 to 14 weeks (for implants with simultaneous bone augmentation). All patients were recalled 36 months following implant placement for a clinical and radiographic examination. RESULTS: One implant failed to integrate during healing, and 11 implants were lost to follow-up and considered dropouts. The remaining 139 implants showed favorable clinical and radiographic findings and were considered successfully integrated at the 3-year examination. This resulted in a 3-year success rate of 99.3%. Radiographic evaluation of 134 implants indicated stability of the crestal bone levels: During the study period, the crestal bone level changed less than 0.5 mm for 129 implants. CONCLUSION: Successful tissue integration was achieved with wide-body implants with a regular or a wide-neck configuration and an SLA surface with high predictability. This successful tissue integration was well maintained for up to 3 years of follow-up.
Resumo:
A viscometric affinity sensor has been developed to measure the interstitial glucose concentration continuously. In a pilot clinical study its performance was assessed under conditions close to everyday life. Additionally, different insertion sites were tested for their suitability to apply subcutaneous glucose sensors.
Resumo:
OBJECTIVES: To determine the clinical performance of a laser fluorescence device (DIAGNOdent pen, KaVo) to discriminate between different occlusal caries depths (D(0)-D(1-4); D(0-2)-D(3,4)) in permanent molars. METHODS: In this prospective, randomized two-centre-study 120 sound/uncavitated carious sites in 120 patients were measured after visual and radiographic caries assessment. In cases of operative intervention (n=86), the lesion depths after caries removal were recorded (reference). In cases of preventive intervention (n=34), the sites were reassessed visually/radiographically after 12 months to verify the status assessed before (reference). The discrimination performance was determined statistically (Mann-Whitney test, Spearman's rho coefficient, and areas under the receiver operating characteristic curves (AUCs)). Sensitivities (SE) and specificities (SP) were plotted as a function of the measured values and cut-off values for the mentioned thresholds suggested. RESULTS: Sound sites (n=13) had significantly minor fluorescence values than carious sites (n=107) (P<0.0001) as had sites with no/enamel caries (n=63) compared to dentinal caries (n=57). The AUCs for the same discriminations were 0.92 and 0.78 (P<0.001). For the D(0)-D(1-4) threshold, a cut-off at a value of 12 (SE: 0.88, SP: 0.85) and for the D(0-2)-D(3,4) threshold at 25 (SE: 0.67, SP: 0.79) can be suggested. A moderate positive correlation between the measurements and the caries depths was calculated (rho=+0.57, P=0.01). CONCLUSION: Within this study, the device's discrimination performance for different caries depths was moderate to very good and it may be recommended as adjunct tool in the diagnosis of occlusal caries.
Resumo:
PURPOSE: This systematic review sought to determine the long-term clinical survival rates of single-tooth restorations fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology, as well as the frequency of failures depending on the CAD/CAM system, the type of restoration, the selected material, and the luting agent. MATERIALS AND METHODS: An electronic search from 1985 to 2007 was performed using two databases: Medline/PubMed and Embase. Selected keywords and well-defined inclusion and exclusion criteria guided the search. All articles were first reviewed by title, then by abstract, and subsequently by a full text reading. Data were assessed and extracted by two independent examiners. The pooled results were statistically analyzed and the overall failure rate was calculated by assuming a Poisson-distributed number of events. In addition, reported failures were analyzed by CAD/CAM system, type of restoration, restorative material, and luting agent. RESULTS: From a total of 1,957 single-tooth restorations with a mean exposure time of 7.9 years and 170 failures, the failure rate was 1.75% per year, estimated per 100 restoration years (95% CI: 1.22% to 2.52%). The estimated total survival rate after 5 years of 91.6% (95% CI: 88.2% to 94.1%) was based on random-effects Poisson regression analysis. CONCLUSIONS: Long-term survival rates for CAD/CAM single-tooth Cerec 1, Cerec 2, and Celay restorations appear to be similar to conventional ones. No clinical studies or randomized clinical trials reporting on other CAD/CAM systems currently used in clinical practice and with follow-up reports of 3 or more years were found at the time of the search.
Resumo:
BACKGROUND We describe the setup of a neonatal quality improvement tool and list which peer-reviewed requirements it fulfils and which it does not. We report on the so-far observed effects, how the units can identify quality improvement potential, and how they can measure the effect of changes made to improve quality. METHODS Application of a prospective longitudinal national cohort data collection that uses algorithms to ensure high data quality (i.e. checks for completeness, plausibility and reliability), and to perform data imaging (Plsek's p-charts and standardized mortality or morbidity ratio SMR charts). The collected data allows monitoring a study collective of very low birth-weight infants born from 2009 to 2011 by applying a quality cycle following the steps 'guideline - perform - falsify - reform'. RESULTS 2025 VLBW live-births from 2009 to 2011 representing 96.1% of all VLBW live-births in Switzerland display a similar mortality rate but better morbidity rates when compared to other networks. Data quality in general is high but subject to improvement in some units. Seven measurements display quality improvement potential in individual units. The methods used fulfil several international recommendations. CONCLUSIONS The Quality Cycle of the Swiss Neonatal Network is a helpful instrument to monitor and gradually help improve the quality of care in a region with high quality standards and low statistical discrimination capacity.
Resumo:
PURPOSE To assess the survival outcomes and reported complications of screw- and cement-retained fixed reconstructions supported on dental implants. MATERIALS AND METHODS A Medline (PubMed), Embase, and Cochrane electronic database search from 2000 to September 2012 using MeSH and free-text terms was conducted. Selected inclusion and exclusion criteria guided the search. All studies were first reviewed by abstract and subsequently by full-text reading by two examiners independently. Data were extracted by two examiners and statistically analyzed using a random effects Poisson regression. RESULTS From 4,324 abstracts, 321 full-text articles were reviewed. Seventy-three articles were found to qualify for inclusion. Five-year survival rates of 96.03% (95% confidence interval [CI]: 93.85% to 97.43%) and 95.55% (95% CI: 92.96% to 97.19%) were calculated for cemented and screw-retained reconstructions, respectively (P = .69). Comparison of cement and screw retention showed no difference when grouped as single crowns (I-SC) (P = .10) or fixed partial dentures (I-FDP) (P = .49). The 5-year survival rate for screw-retained full-arch reconstructions was 96.71% (95% CI: 93.66% to 98.31). All-ceramic reconstruction material exhibited a significantly higher failure rate than porcelain-fused-to-metal (PFM) in cemented reconstructions (P = .01) but not when comparing screw-retained reconstructions (P = .66). Technical and biologic complications demonstrating a statistically significant difference included loss of retention (P ≤ .01), abutment loosening (P ≤ .01), porcelain fracture and/or chipping (P = .02), presence of fistula/suppuration (P ≤ .001), total technical events (P = .03), and total biologic events (P = .02). CONCLUSIONS Although no statistical difference was found between cement- and screw-retained reconstructions for survival or failure rates, screw-retained reconstructions exhibited fewer technical and biologic complications overall. There were no statistically significant differences between the failure rates of the different reconstruction types (I-SCs, I-FDPs, full-arch I-FDPs) or abutment materials (titanium, gold, ceramic). The failure rate of cemented reconstructions was not influenced by the choice of a specific cement, though cement type did influence loss of retention.
Resumo:
OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.
Resumo:
The authors conducted an in vivo study to determine clinical cutoffs for a laser fluorescence (LF) device, an LF pen and a fluorescence camera (FC), as well as to evaluate the clinical performance of these methods and conventional methods in detecting occlusal caries in permanent teeth by using the histologic gold standard for total validation of the sample.
Resumo:
Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.
Resumo:
BACKGROUND CONTEXT The nerve root sedimentation sign in transverse magnetic resonance imaging has been shown to discriminate well between selected patients with and without lumbar spinal stenosis (LSS), but the performance of this new test, when used in a broader patient population, is not yet known. PURPOSE To evaluate the clinical performance of the nerve root sedimentation sign in detecting central LSS above L5 and to determine its potential significance for treatment decisions. STUDY DESIGN Retrospective cohort study. PATIENT SAMPLE One hundred eighteen consecutive patients with suspected LSS (52% women, median age 62 years) with a median follow-up of 24 months. OUTCOME MEASURES Oswestry disability index (ODI) and back and leg pain relief. METHODS We performed a clinical test validation study to assess the clinical performance of the sign by measuring its association with health outcomes. Subjects were patients referred to our orthopedic spine unit from 2004 to 2007 before the sign had been described. Based on clinical and radiological diagnostics, patients had been treated with decompression surgery or nonsurgical treatment. Changes in the ODI and pain from baseline to 24-month follow-up were compared between sedimentation sign positives and negatives in both treatment groups. RESULTS Sixty-nine patients underwent surgery. Average baseline ODI in the surgical group was 54.7%, and the sign was positive in 39 patients (mean ODI improvement 29.0 points) and negative in 30 (ODI improvement 28.4), with no statistically significant difference in ODI and pain improvement between groups. In the 49 patients of the nonsurgical group, mean baseline ODI was 42.4%; the sign was positive in 18 (ODI improvement 0.6) and negative in 31 (ODI improvement 17.7). A positive sign was associated with a smaller ODI and back pain improvement than negative signs (both p<.01 on t test). CONCLUSIONS In patients commonly treated with decompression surgery, the sedimentation sign does not appear to predict surgical outcome. In nonsurgically treated patients, a positive sign is associated with more limited improvement. In these cases, surgery might be effective, but this needs investigation in prospective randomized trials (Australian New Zealand Clinical Trial Registry, number ACTRN12610000567022).
Resumo:
Endodontic treatment, involves removal of the dental pulp and its replacement by a root canal filling. Restoration of root filled teeth can be challenging due to structural differences between vital and non-vital root filled teeth. Direct restoration involves placement of a restorative material e.g. amalgam or composite directly into the tooth. Indirect restorations consist of cast metal or ceramic (porcelain) crowns. The choice of restoration depends on the amount of remaining tooth which may influence long term survival and cost. The comparative in service clinical performance of crowns or conventional fillings used to restore root filled teeth is unclear.
Resumo:
Retention of overdentures is important for patients' satisfaction. The study tested whether the clinical performance of retentive clips made of poly-ether-ether-ketone (PEEK) is superior to those made of poly-oxy-methylene (POM).
Resumo:
In 2005 the Swiss government implemented new work-hour limitations for all residency programs in Switzerland, including a 50-hour weekly limit. The reduction in the working hours of doctors in training implicate an increase in their rest time and suggest an amelioration of doctors' clinical performance and consequently in patients' outcomes and safety - which was not detectable in a preliminary study at a large referral center in Switzerland. It remains elusive why work-hour restrictions did not improve patient safety. We are well advised to thoroughly examine and eliminate the known adverse effects of reduced work-hours to improve our patients' safety.