10 resultados para Chinese digital generation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To compare the intravascular ultrasound virtual histology (IVUS-VH) appearance of the polymeric struts of the first (Revision 1.0) and the second (Revision 1.1) generation bioresorbable vascular scaffold (BVS).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Chinese herbal medicine (CHM) is increasingly used in the West, but the evidence on its effectiveness is a matter of debate. We compared the characteristics, study quality and results of clinical trials of CHM and conventional medicine. METHODS: Comparative study of placebo-controlled trials of CHM and conventional medicine. Eleven bibliographic databases and searches by hand of 48 Chinese-language journals. Conventional medicine trials matched for condition and type of outcome were randomly selected from the Cochrane Controlled Trials Register (issue 1, 2003). Trials described as double-blind, with adequate generation of allocation sequence and adequate concealment of allocation, were assumed to be of high quality. Data were analysed using funnel plots and multivariable meta-regression models. RESULTS: 136 CHM trials (119 published in Chinese, 17 published in English) and 136 matched conventional medicine trials (125 published in English) were analysed. The quality of Chinese-language CHM trials tended to be lower than that of English-language CHM trials and conventional medicine trials. Three (2%) CHM trials and 10 (7%) conventional medicine trials were of high quality. In all groups, smaller trials showed more beneficial treatment effects than larger trials. CHM trials published in Chinese showed considerably larger effects than CHM trials published in English (adjusted ratio of ORs 0.29, 95% confidence intervals 0.17-0.52). CONCLUSIONS: Biases are present both in placebo-controlled trials of CHM and conventional medicine, but may be most pronounced in CHM trials published in Chinese-language journals. Only few CHM trials of adequate methodology exist and the effectiveness of CHM therefore remains poorly documented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: Early-generation drug-eluting stent (DES) overlap (OL) is associated with impaired long-term clinical outcomes whereas the impact of OL with newer-generation DES is unknown. Our aim was to assess the impact of OL on long-term clinical outcomes among patients treated with newer-generation DES. Methods and results: We analysed the three-year clinical outcomes of 3,133 patients included in a prospective DES registry according to stent type (sirolimus-eluting stents [SES; N=1,532] versus everolimus-eluting stents [EES; N=1,601]), and the presence or absence of OL. The primary outcome was a composite of death, myocardial infarction (MI), and target vessel revascularisation (TVR). The primary endpoint was more common in patients with OL (25.1%) than in those with multiple DES without OL (20.8%, adj HR=1.46, 95% CI: 1.03-2.09) and patients with a single DES (18.8%, adj HR=1.74, 95% CI: 1.34-2.25, p<0.001) at three years. A stratified analysis by stent type showed a higher risk of the primary outcome in SES with OL (28.7%) compared to other SES groups (without OL: 22.6%, p=0.04; single DES: 17.6%, p<0.001), but not between EES with OL (22.3%) and other EES groups (without OL: 18.5%, p=0.30; single DES: 20.4%, p=0.20). Conclusions: DES overlap is associated with impaired clinical outcomes during long-term follow-up. Compared with SES, EES provide similar clinical outcomes irrespective of DES overlap status.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Tissue microarray (TMA) technology revolutionized the investigation of potential biomarkers from paraffin-embedded tissues. However, conventional TMA construction is laborious, time-consuming and imprecise. Next-generation tissue microarrays (ngTMA) combine histological expertise with digital pathology and automated tissue microarraying. The aim of this study was to test the feasibility of ngTMA for the investigation of biomarkers within the tumor microenvironment (tumor center and invasion front) of six tumor types, using CD3, CD8 and CD45RO as an example. Methods Ten cases each of malignant melanoma, lung, breast, gastric, prostate and colorectal cancers were reviewed. The most representative H&E slide was scanned and uploaded onto a digital slide management platform. Slides were viewed and seven TMA annotations of 1 mm in diameter were placed directly onto the digital slide. Different colors were used to identify the exact regions in normal tissue (n = 1), tumor center (n = 2), tumor front (n = 2), and tumor microenvironment at invasion front (n = 2) for subsequent punching. Donor blocks were loaded into an automated tissue microarrayer. Images of the donor block were superimposed with annotated digital slides. Exact annotated regions were punched out of each donor block and transferred into a TMA block. 420 tissue cores created two ngTMA blocks. H&E staining and immunohistochemistry for CD3, CD8 and CD45RO were performed. Results All 60 slides were scanned automatically (total time < 10 hours), uploaded and viewed. Annotation time was 1 hour. The 60 donor blocks were loaded into the tissue microarrayer, simultaneously. Alignment of donor block images and digital slides was possible in less than 2 minutes/case. Automated punching of tissue cores and transfer took 12 seconds/core. Total ngTMA construction time was 1.4 hours. Stains for H&E and CD3, CD8 and CD45RO highlighted the precision with which ngTMA could capture regions of tumor-stroma interaction of each cancer and the T-lymphocytic immune reaction within the tumor microenvironment. Conclusion Based on a manual selection criteria, ngTMA is able to precisely capture histological zones or cell types of interest in a precise and accurate way, aiding the pathological study of the tumor microenvironment. This approach would be advantageous for visualizing proteins, DNA, mRNA and microRNAs in specific cell types using in situ hybridization techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The combination of scaled analogue experiments, material mechanics, X-ray computed tomography (XRCT) and Digital Volume Correlation techniques (DVC) is a powerful new tool not only to examine the 3 dimensional structure and kinematic evolution of complex deformation structures in scaled analogue experiments, but also to fully quantify their spatial strain distribution and complete strain history. Digital image correlation (DIC) is an important advance in quantitative physical modelling and helps to understand non-linear deformation processes. Optical non-intrusive (DIC) techniques enable the quantification of localised and distributed deformation in analogue experiments based either on images taken through transparent sidewalls (2D DIC) or on surface views (3D DIC). X-ray computed tomography (XRCT) analysis permits the non-destructive visualisation of the internal structure and kinematic evolution of scaled analogue experiments simulating tectonic evolution of complex geological structures. The combination of XRCT sectional image data of analogue experiments with 2D DIC only allows quantification of 2D displacement and strain components in section direction. This completely omits the potential of CT experiments for full 3D strain analysis of complex, non-cylindrical deformation structures. In this study, we apply digital volume correlation (DVC) techniques on XRCT scan data of “solid” analogue experiments to fully quantify the internal displacement and strain in 3 dimensions over time. Our first results indicate that the application of DVC techniques on XRCT volume data can successfully be used to quantify the 3D spatial and temporal strain patterns inside analogue experiments. We demonstrate the potential of combining DVC techniques and XRCT volume imaging for 3D strain analysis of a contractional experiment simulating the development of a non-cylindrical pop-up structure. Furthermore, we discuss various options for optimisation of granular materials, pattern generation, and data acquisition for increased resolution and accuracy of the strain results. Three-dimensional strain analysis of analogue models is of particular interest for geological and seismic interpretations of complex, non-cylindrical geological structures. The volume strain data enable the analysis of the large-scale and small-scale strain history of geological structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper seeks a re-conceptualization of the global digital divide debate. It critically explores the predominant notion, its evolution and measurement, as well as the policies that have been advanced to bridge the digital divide. Acknowledging the complexity of this inequality, the paper aims at analyzing the disparities beyond the connectivity and the skills barriers. Without understating the first two digital divides, it is argued that as the Internet becomes more sophisticated and more integrated into economic, social and cultural processes, a ‘third’ generation of divides becomes critical. These divides are drawn not at the entry to the net but within the net itself, and limit access to content. The increasing barriers to content, although of diverse nature, all relate to some governance characteristics inherent in cyberspace, such as global spillover of local decisions, regulation through code or proliferation of self- and co-regulatory models. It is maintained that as the practice of intervention intensifies in cyberspace, multiple and far-reaching points of control outside formal legal institutions are created, which threaten the availability of public goods and make the pursuit of public objectives difficult. This is an aspect that is rarely addressed in the global digital divide discussions, even in comprehensive analysis and political initiatives such as the World Summit on the Information Society. Yet, the conceptualization of the digital divide as impeded access to content may be key in terms of ensuring real participation and catering for the long-term implications of digital technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The article seeks a re-conceptualization of the global digital divide debate. It critically explores the predominant notion, its evolution and measurement, as well as the policies that have been advanced to bridge the digital divide. Acknowledging the complexity of this inequality, the article aims at analyzing the disparities beyond the connectivity and skills barriers. Without understating the first two digital divides, it is argued that as the Internet becomes more sophisticated and more integrated into economic, social, and cultural processes, a “third” generation of divides becomes critical. These divides are drawn not at the entry to the net but within the net itself, and limit access to content. The increasing barriers to content, though of a diverse nature, all relate to some governance characteristics inherent in cyberspace, such as global spillover of local decisions, regulation through code, and proliferation of self- and co-regulatory models. It is maintained that as the practice of intervention intensifies in cyberspace, multiple and far-reaching points of control outside formal legal institutions are created, threatening the availability of public goods and making the pursuit of public objectives difficult. This is an aspect that is rarely addressed in the global digital divide discussions, even in comprehensive analyses and political initiatives such as the World Summit on the Information Society. Yet, the conceptualization of the digital divide as impeded access to content may be key in terms of ensuring real participation and catering for the long-term implications of digital technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biomarker research relies on tissue microarrays (TMA). TMAs are produced by repeated transfer of small tissue cores from a 'donor' block into a 'recipient' block and then used for a variety of biomarker applications. The construction of conventional TMAs is labor intensive, imprecise, and time-consuming. Here, a protocol using next-generation Tissue Microarrays (ngTMA) is outlined. ngTMA is based on TMA planning and design, digital pathology, and automated tissue microarraying. The protocol is illustrated using an example of 134 metastatic colorectal cancer patients. Histological, statistical and logistical aspects are considered, such as the tissue type, specific histological regions, and cell types for inclusion in the TMA, the number of tissue spots, sample size, statistical analysis, and number of TMA copies. Histological slides for each patient are scanned and uploaded onto a web-based digital platform. There, they are viewed and annotated (marked) using a 0.6-2.0 mm diameter tool, multiple times using various colors to distinguish tissue areas. Donor blocks and 12 'recipient' blocks are loaded into the instrument. Digital slides are retrieved and matched to donor block images. Repeated arraying of annotated regions is automatically performed resulting in an ngTMA. In this example, six ngTMAs are planned containing six different tissue types/histological zones. Two copies of the ngTMAs are desired. Three to four slides for each patient are scanned; 3 scan runs are necessary and performed overnight. All slides are annotated; different colors are used to represent the different tissues/zones, namely tumor center, invasion front, tumor/stroma, lymph node metastases, liver metastases, and normal tissue. 17 annotations/case are made; time for annotation is 2-3 min/case. 12 ngTMAs are produced containing 4,556 spots. Arraying time is 15-20 hr. Due to its precision, flexibility and speed, ngTMA is a powerful tool to further improve the quality of TMAs used in clinical and translational research.