118 resultados para Cervical restorations
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To compare the performance of LFpen (DIAGNOdent pen) with two different wedge-shaped tips to conventional bitewing radiography (BW) for detecting proximal secondary caries at the cervical margin of amalgam restorations in vitro.
Resumo:
The goals of any treatment of cervical spine injuries are: return to maximum functional ability, minimum of residual pain, decrease of any neurological deficit, minimum of residual deformity and prevention of further disability. The advantages of surgical treatment are the ability to reach optimal reduction, immediate stability, direct decompression of the cord and the exiting roots, the need for only minimum external fixation, the possibility for early mobilisation and clearly decreased nursing problems. There are some reasons why those goals can be reached better by anterior surgery. Usually the bony compression of the cord and roots comes from the front therefore anterior decompression is usually the procedure of choice. Also, the anterior stabilisation with a plate is usually simpler than a posterior instrumentation. It needs to be stressed that closed reduction by traction can align the fractured spine and indirectly decompress the neural structures in about 70%. The necessary weight is 2.5 kg per level of injury. In the upper cervical spine, the odontoid fracture type 2 is an indication for anterior surgery by direct screw fixation. Joint C1/C2 dislocations or fractures or certain odontoid fractures can be treated with a fusion of the C1/C2 joint by anterior transarticular screw fixation. In the lower and middle cervical spine, anterior plating combined with iliac crest or fibular strut graft is the procedure of choice, however, a solid graft can also be replaced by filled solid or expandable vertebral cages. The complication of this surgery is low, when properly executed and anterior surgery may only be contra-indicated in case of a significant lesion or locked joints.
Resumo:
This study evaluated the performance of the DIAGNOdent pen laser fluorescence device (LFpen) in comparison with visual examination (VE), bitewing radiographs (BW) and visual examination combined with bitewing radiographs (VEBW) in detecting secondary approximal caries associated with composite restorations. In total, 60 approximal surfaces from 43 permanent molars with composite restorations were assessed twice by two examiners using the LFpen, VE, BW and VEBW. After histological preparation and hardness measurements, the sample was assigned to either a crown or root caries group, depending on the location of the lesions as the gold standard. For crown caries at D1, the highest values of specificity and sensitivity were observed for the LFpen at a cutoff value of 18 (1.00) and for the VEBW (0.89). At D3 (cutoff of 30), the LFpen showed the highest values of sensitivity and specificity. For root caries, the LFpen and VEBW showed the highest values of specificity (0.54), sensitivity (0.81) and accuracy (0.69). The Spearman rank correlation coefficients for crown/root caries with histology were 0.54/0.37 (LFpen), 0.29/0.10 (BW), 0.29/0.18 (VE) and 0.23/0.37 (VEBW). For the LFpen, the ICC varied from 0.80 (interexaminer) to 0.97 (intraexaminer B); the kappa value was 0.19 for BW and 0.35 for VE (interexaminer). Intraexaminer kappa values for BW were 0.25 (A) and 0.29 (B), and those for VE were 0.31 (A) and 0.32 (B). The LFpen device exhibited a performance comparable to that of conventional methods but with higher interexaminer reproducibility. Therefore, the LFpen should be considered an auxiliary method for the detection of secondary approximal caries associated with composite restorations.
Resumo:
This in vitro study evaluated the performance of three ceramic and two commonly used polishing methods on two CAD/CAM ceramics. Surface roughness and quality were compared. A glazed group (GLGR) of each ceramic material served as reference. One-hundred and twenty specimens of VITABLOCS Mark II (VITA) and 120 specimens of IPS Empress CAD (IPS) were roughened in a standardized manner. Twenty VITA and 20 IPS specimens were glazed (VITA Akzent Glaze/Empress Universal Glaze). Five polishing methods were investigated (n=20/group): 1) EVE Diacera W11DC-Set (EVE), 2) JOTA 9812-Set (JOTA), 3) OptraFine-System (OFI), 4) Sof-Lex 2382 discs (SOF) and 5) Brownie/Greenie/Occlubrush (BGO). Polishing quality was measured with a surface roughness meter (Ra and Rz values). The significance level was set at alpha=0.05. Kruskal Wallis tests and pairwise Wilcoxon rank sum tests with Bonferroni-Holm adjustment were used. Qualitative surface evaluation of representative specimens was done with SEM. On VITA ceramics, SOF produced lower Ra (p<0.00001) but higher Rz values than GLGR (p=0.003); EVE, JOTA, OFI and BGO yielded significantly higher Ra and Rz values than GLGR. On IPS ceramics, SOF and JOTA exhibited lower Ra values than GLGR (p<0.0001). Equivalent Ra but significantly higher Rz values occurred between GLGR and EVE, OFI or BGO. VITA and IPS exhibited the smoothest surfaces when polished with SOF. Nevertheless, ceramic polishing systems are still of interest to clinicians using CAD/CAM, as these methods are universally applicable and showed an increased durability compared to the investigated silicon polishers.
Resumo:
BACKGROUND: Mechanical pain sensitivity is assessed in every patient with pain, either by palpation or by quantitative pressure algometry. Despite widespread use, no studies have formally addressed the usefulness of this practice for the identification of the source of pain. We tested the hypothesis that assessing mechanical pain sensitivity distinguishes damaged from healthy cervical zygapophysial (facet) joints. METHODS: Thirty-three patients with chronic unilateral neck pain were studied. Pressure pain thresholds (PPTs) were assessed bilaterally at all cervical zygapophysial joints. The diagnosis of zygapophysial joint pain was made by selective nerve blocks. Primary analysis was the comparison of the PPT between symptomatic and contralateral asymptomatic joints. The secondary end points were as follows: differences in PPT between affected and asymptomatic joints of the same side of patients with zygapophysial joint pain; differences in PPT at the painful side between patients with and without zygapophysial joint pain; and sensitivity and specificity of PPT for 2 different cutoffs (difference in PPT between affected and contralateral side by 1 and 30 kPa, meaning that the test was considered positive if the difference in PPT between painful and contralateral side was negative by at least 1 and 30 kPa, respectively). The PPT of patients was also compared with the PPT of 12 pain-free subjects. RESULTS: Zygapophysial joint pain was present in 14 patients. In these cases, the difference in mean PPT between affected and contralateral side (primary analysis) was −6.2 kPa (95% confidence interval: −19.5 to 7.2, P = 0.34). In addition, the secondary analyses yielded no statistically significant differences. For the cutoff of 1 kPa, sensitivity and specificity of PPT were 67% and 16%, respectively, resulting in a positive likelihood ratio of 0.79 and a diagnostic confidence of 38%. When the cutoff of 30 kPa was considered, the sensitivity decreased to only 13%, whereas the specificity increased to 95%, resulting in a positive likelihood ratio of 2.53 and a diagnostic confidence of 67%. The PPT was significantly lower in patients than in pain-free subjects (P < 0.001). CONCLUSIONS: Assessing mechanical pain sensitivity is not diagnostic for cervical zygapophysial joint pain. The finding should stimulate further research into a diagnostic tool that is widely used in the clinical examination of patients with pain.
Resumo:
Prospective multicenter observational case-series.
Resumo:
Syphilis (lues), a chronic infectious disease caused by Treponema pallidum, has been increasing in incidence during the last few years. Therefore, while clinically it is often not suspected, syphilis is increasingly becoming a differential diagnosis in routine pathology.
Resumo:
Subjects with temporomandibular disorders (TMDs) have been found to have clinical signs and symptoms of cervical dysfunction. Although many studies have investigated the relationship between the cervical spine and TMD, no study has evaluated the endurance capacity of the cervical muscles in patients with TMD. Thus the objective of this study was to determine whether patients with TMD had a reduced endurance of the cervical flexor muscles at any level of muscular contraction when compared with healthy subjects. One hundred and forty-nine participants provided data for this study (49 subjects were healthy, 54 had myogenous TMD, and 46 had mixed TMD). There was a significant difference in holding time at 25% MVC between subjects with mixed TMD when compared to subjects with myogenous TMD and healthy subjects. This implies that subjects with mixed TMD had less endurance capacity at a lower level of contraction (25% MVC) than healthy subjects and subjects with myogenous TMD. No significant associations between neck disability, jaw disability, clinical variables and neck flexor endurance test were found.
Resumo:
To quantitatively compare the muscle cross-sectional areas (CSAs) of the cervical muscles in symptomatic acute whiplash patients versus healthy controls. We hypothesized, that symptomatic whiplash patients have smaller cervical muscle CSAs than matched controls and that smaller cervical muscle CSAs in women might explain that women more frequently are symptomatic after whiplash injury than men.
Resumo:
Because the recommendation to use flowables for posterior restorations is still a matter of debate, the objective of this study was to determine in a nationwide survey in Germany how frequently, for what indications, and for what reasons, German dentists use flowable composites in posterior teeth. In addition, the acceptance of a simplified filling technique for posterior restorations using a low stress flowable composite was evaluated. Completed questionnaires from all over Germany were returned by 1,449 dentists resulting in a response rate of 48.5%; 78.6% of whom regularly used flowable composites for posterior restorations. The most frequent indications were cavity lining (80.1%) and small Class I fillings (74.2%). Flowables were less frequently used for small Class II fillings (22.7%) or other indications (13.6%). Most frequent reasons given for the use of flowables in posterior teeth were the prevention of voids (71.7%) and superior adaptation to cavity walls (72.9%), whereas saving time was considered less important (13.8%). Based on the subjective opinion of the dentists the simplified filling technique seemed to deliver advantages compared to the methods used to date particularly with regard to good cavity adaptation and ease of use. In conclusion, resin composites are the standard material type used for posterior restorations by general dental practitioners in Germany and most dentists use flowable composites as liners.