4 resultados para Cerenkov counters

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A physical random number generator based on the intrinsic randomness of quantum mechanics is described. The random events are realized by the choice of single photons between the two outputs of a beamsplitter. We present a simple device, which minimizes the impact of the photon counters’ noise, dead-time and after pulses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although it is well documented that low self-esteem and depression are related, the precise nature of the relation has been a topic of ongoing debate. We describe several theoretical models concerning the link between self-esteem and depression, and review recent research evaluating the validity of these competing models. Overall, the available evidence provides strong support for the vulnerability model (low self-esteem contributes to depression), weaker support for the scar model (depression erodes self-esteem), and little support for alternative accounts such as the diathesis-stress model. Moreover, the vulnerability model is robust and holds across gender, age, affective-cognitive versus somatic symptoms of depression, European background versus Mexican-origin participants, and clinical versus nonclinical samples. Research on further specifications of the vulnerability model suggests that the effect is (a) partially mediated by rumination, (b) not influenced by other characteristics of self-esteem (i.e., stability and contingency), and (c) driven predominantly by global rather than domain-specific self-esteem. The research has important theoretical implications because it counters the commonly repeated claim that self-esteem has no long-term impact. Moreover, the research has important practical implications, suggesting that depression can be prevented, or reduced, by interventions that improve self-esteem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When an ice core sample is analysed for its aeolian dust content, it is melted and the particles detected are suspended in water. Consequently, dust measurement techniques employed in the ice core community differ from those used for in-situ studies of airborne dust. Methods commonly used to classify insolubles suspended in a liquid are either based on the particles’ interaction with light or on the detection of resistive pulses by means of Coulter counting. Data sets obtained with Coulter counters are widely accepted as references and other techniques are judged against their ability to reproduce these. Unfortunately, optically acquired ice core dust records were found to differ. By analyzing two sections of the NEEM dust record, two different evaluation procedures are discussed before a third protocol is proposed. It is found that relative changes in the archived dust load can be reproduced, while the simultaneous attainment of absolute concentrations or changes in the grain size frequency histograms in high resolution remains difficult.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radioactivity induced by a 15-MeV proton beam extracted into air was studied at the beam transport line of the 18-MeV cyclotron at the Bern University Hospital (Inselspital). The produced radioactivity was calculated and measured by means of proportional counters located at the main exhaust of the laboratory. These devices were designed for precise assessment of air contamination for radiation protection purposes. The main produced isotopes were 11C, 13N and 14O. Both measurements and calculations correspond to two different irradiation conditions. In the former, protons were allowed to travel for their full range in air. In the latter, they were stopped at the distance of 1.5 m by a beam dump. Radioactivity was measured continuously in the exhausted air starting from 2 min after the end of irradiation. For this reason, the short-lived 14O isotope gave a negligible contribution to the measured activity. Good agreement was found between the measurements and the calculations within the estimated uncertainties. Currents in the range of 120–370 nA were extracted in air for 10–30 s producing activities of 9–22 MBq of 11C and 13N. The total activities for 11C and 13N per beam current and irradiation time for the former and the latter irradiation conditions were measured to be (3.60 ± 0.48) × 10−3 MBq (nA s)−1 and (2.89 ± 0.37) × 10−3 MBq (nA s)−1, respectively.