6 resultados para Cathodic cage. Iron nitride film. Saturation magnetization

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matriptase-2 (Tmprss6), a type II transmembrane serine protease, has an essential role in iron homoeostasis as a hepcidin regulator. Recently, patients with TMPRSS6 mutations and suffering from iron-refractory iron deficiency anaemia (IRIDA) have been reported. We describe two new cases of IRIDA, one patient of Swiss origin and the second of Italian origin. The first case results from a large deletion of 1054 nucleotides corresponding to an in frame deletion of 30 amino acid residues in the low-density lipoprotein receptor-1/-2 (LDLR-1/-2) domains and from a missense mutation in CUB1 (S304L). In the second case, a homozygous G-->C mutation in the last nucleotide of exon 15 and which modified the consensus sequence of the 5' splice donor site of intron 15 (AGgt-->ACgt) was identified. Both patients had a high hepcidin level and low serum iron and transferrin saturation compared to age-matched controls. Continuous perfusion of i.v. iron 4 h/d x 5 d in the first case resulted in a significant rise in haemoglobin. These new cases of IRIDA illustrate the importance of LDLR-1/-2 and CUB1 domains in matriptase-2 function as well as the role of matriptase-2 in hepcidin regulation. Furthermore a deletional form of TMPRSS6 (in LDLR-1/-2 domains) resulting in IRIDA is described for the first time. These cases reinforce the belief that patients suffering from IRIDA have no specific geographical or ethnic distribution and are sporadic secondary to different mutations of the matriptase-2 gene.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

(31)P MRS magnetization transfer ((31)P-MT) experiments allow the estimation of exchange rates of biochemical reactions, such as the creatine kinase equilibrium and adenosine triphosphate (ATP) synthesis. Although various (31)P-MT methods have been successfully used on isolated organs or animals, their application on humans in clinical scanners poses specific challenges. This study compared two major (31)P-MT methods on a clinical MR system using heteronuclear surface coils. Although saturation transfer (ST) is the most commonly used (31)P-MT method, sequences such as inversion transfer (IT) with short pulses might be better suited for the specific hardware and software limitations of a clinical scanner. In addition, small NMR-undetectable metabolite pools can transfer MT to NMR-visible pools during long saturation pulses, which is prevented with short pulses. (31)P-MT sequences were adapted for limited pulse length, for heteronuclear transmit-receive surface coils with inhomogeneous B1 , for the need for volume selection and for the inherently low signal-to-noise ratio (SNR) on a clinical 3-T MR system. The ST and IT sequences were applied to skeletal muscle and liver in 10 healthy volunteers. Monte-Carlo simulations were used to evaluate the behavior of the IT measurements with increasing imperfections. In skeletal muscle of the thigh, ATP synthesis resulted in forward reaction constants (k) of 0.074 ± 0.022 s(-1) (ST) and 0.137 ± 0.042 s(-1) (IT), whereas the creatine kinase reaction yielded 0.459 ± 0.089 s(-1) (IT). In the liver, ATP synthesis resulted in k = 0.267 ± 0.106 s(-1) (ST), whereas the IT experiment yielded no consistent results. ST results were close to literature values; however, the IT results were either much larger than the corresponding ST values and/or were widely scattered. To summarize, ST and IT experiments can both be implemented on a clinical body scanner with heteronuclear transmit-receive surface coils; however, ST results are much more robust against experimental imperfections than the current implementation of IT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of water suppression for in vivo proton MR spectroscopy diminishes the signal intensities from resonances that undergo magnetization exchange with water, particularly those downfield of water. To investigate these exchangeable resonances, an inversion transfer experiment was performed using the metabolite cycling technique for non-water-suppressed MR spectroscopy from a large brain voxel in 11 healthy volunteers at 3.0 T. The exchange rates of the most prominent peaks downfield of water were found to range from 0.5 to 8.9 s(-1), while the T(1) relaxation times in absence of exchange were found to range from 175 to 525 ms. These findings may help toward the assignments of the downfield resonances and a better understanding of the sources of contrast in chemical exchange saturation transfer imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Restless legs syndrome (RLS) is a common multifactorial disease. Some genetic risk factors have been identified. RLS susceptibility also has been related to iron. We therefore asked whether known iron-related genes are candidates for association with RLS and, vice versa, whether known RLS-associated loci influence iron parameters in serum. RLS/control samples (n = 954/1814 in the discovery step, 735/736 in replication 1, and 736/735 in replication 2) were tested for association with SNPs located within 4 Mb intervals surrounding each gene from a list of 111 iron-related genes using a discovery threshold of P = 5 × 10(-4). Two population cohorts (KORA F3 and F4 with together n = 3447) were tested for association of six known RLS loci with iron, ferritin, transferrin, transferrin-saturation, and soluble transferrin receptor. Results were negative. None of the candidate SNPs at the iron-related gene loci was confirmed significantly. An intronic SNP, rs2576036, of KATNAL2 at 18q21.1 was significant in the first (P = 0.00085) but not in the second replication step (joint nominal P-value = 0.044). Especially, rs1800652 (C282Y) in the HFE gene did not associate with RLS. Moreover, SNPs at the known RLS loci did not significantly affect serum iron parameters in the KORA cohorts. In conclusion, the correlation between RLS and iron parameters in serum may be weaker than assumed. Moreover, in a general power analysis, we show that genetic effects are diluted if they are transmitted via an intermediate trait to an end-phenotype. Sample size formulas are provided for small effect sizes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Anemia has been shown to be a risk factor for coronary artery disease and mortality. The involvement of body iron stores in the development of CAD remains controversial. So far, studies that examined hemoglobin and parameters of iron metabolism simultaneously do not exist. METHODS AND RESULTS Hemoglobin and iron status were determined in 1480 patients with stable angiographic coronary artery disease (CAD) and in 682 individuals in whom CAD had been ruled out by angiography. The multivariate adjusted odds ratios (OR) for CAD in the lowest quartiles of hemoglobin and iron were 1.62 (95%CI: 1.22-2.16), and 2.05 (95%CI: 1.51-2.78), respectively compared to their highest gender-specific quartiles. The fully adjusted ORs for CAD in the lowest quartiles of transferrin saturation, ferritin (F) and soluble transferrin receptor (sTfR)/log10F index were 1.69 (95%CI: 1.25-2.27), 1.98 (95%CI: 1.48-2.65), and 1.64 (95%CI: 1.23-2.18), respectively compared to their highest gender-specific quartiles. When adjusting in addition for iron and ferritin the OR for CAD in the lowest quartiles of hemoglobin was still 1.40 (95%CI: 1.04-1.90) compared to the highest gender-specific quartiles. Thus, the associations between either iron status or low hemoglobin and CAD appeared independent from each other. The sTfR was only marginally associated with angiographic CAD. CONCLUSIONS Both low hemoglobin and iron depletion are independently associated with angiographic CAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SBR759 is a novel polynuclear iron(III) oxide–hydroxide starch·sucrose·carbonate complex being developed for oral use in chronic kidney disease (CKD) patients with hyperphosphatemia on hemodialysis. SBR759 binds inorganic phosphate released by food uptake and digestion in the gastro-intestinal tract increasing the fecal excretion of phosphate with concomitant reduction of serum phosphate concentrations. Considering the high content of ∼20% w/w covalently bound iron in SBR759 and expected chronic administration to patients, absorption of small amounts of iron released from the drug substance could result in potential iron overload and toxicity. In a mechanistic iron uptake study, 12 healthy male subjects (receiving comparable low phosphorus-containing meal typical for CKD patients: ≤1000 mg phosphate per day) were treated with 12 g (divided in 3 × 4 g) of stable 58Fe isotope-labeled SBR759. The ferrokinetics of [58Fe]SBR759-related total iron was followed in blood (over 3 weeks) and in plasma (over 26 hours) by analyzing with high precision the isotope ratios of the natural iron isotopes 58Fe, 57Fe, 56Fe and 54Fe by multi-collector inductively coupled mass spectrometry (MC-ICP-MS). Three weeks following dosing, the subjects cumulatively absorbed on average 7.8 ± 3.2 mg (3.8–13.9 mg) iron corresponding to 0.30 ± 0.12% (0.15–0.54%) SBR759-related iron which amounts to approx. 5-fold the basal daily iron absorption of 1–2 mg in humans. SBR759 was well-tolerated and there was no serious adverse event and no clinically significant changes in the iron indices hemoglobin, hematocrit, ferritin concentration and transferrin saturation.