6 resultados para Cate Consandine

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Insufficient control of von Willebrand factor (VWF) multimer size as a result of severely deficient ADAMTS-13 activity results in thrombotic thrombocytopenic purpura associated with microvascluar thrombosis and platelet consumption, features not seldom seen in severe sepsis and septic shock. METHODS: ADAMTS-13 activity and VWF parameters of 40 patients with severe sepsis or septic shock were compared with those of 40 healthy controls of the same age and gender and correlated with clinical findings and sepsis outcome. RESULTS: ADAMTS-13 activity was significantly lower in patients than in healthy controls [median 60% (range 27-160%) vs. 110% (range 63-200%); P < 0.001]. VWF parameters behaved reciprocally and both VWF ristocetin cofactor activity (RCo) and VWF antigen (VWF:Ag) were significantly (P < 0.001) higher in patients compared with controls. Neither ADAMTS-13 activity nor VWF parameters correlated with disease severity, organ dysfunction or outcome. However, a contribution of acute endothelial dysfunction to renal impairment in sepsis is suggested by the significantly higher VWF propeptide and soluble thrombomodulin levels in patients with increased creatinine values as well as by their strong positive correlations (creatinine and VWF propeptide r(s) = 0.484, P < 0.001; creatinine and soluble thrombomodulin r(s) = 0.596, P < 0.001). CONCLUSIONS: VWF parameters are reciprocally correlated with ADAMTS-13 activity in severe sepsis and septic shock but have no prognostic value regarding outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While the use of thromboelastometry analysis (ROTEM®) in evaluation of haemostasis is rapidly increasing, important validity parameters of testing remain inadequately examined. We aimed to study systematically the consistency of thromboelastometry parameters within individual tests regarding measurements between different analysers, between different channels of the same analyser, between morning and afternoon measurements (circadian variation), and if measured four weeks apart. Citrated whole blood samples from 40 healthy volunteers were analysed with two analysers in parallel. EXTEM, INTEM, FIBTEM, HEPTEM and APTEM tests were conducted. A Bland-Altman comparison was performed and homogeneity of variances was tested using the pitman test. P-value ranges were used to classify the level of homogeneity (p<0.15 - low homogeneity, p = 0.15 to 0.5 - intermediate homogeneity, p>0.5 high homogeneity). Less than half of all comparisons made showed high homogeneity of variances (p>0.5) and in about a fifth of comparisons data distributions were heterogeneous (p<0.15). There was no clear pattern for homogeneity. On average, comparisons of MCF, ML and LI30 measurements tended to be better, but none of the tests assessed outperformed another. In conclusion, systematic investigation reveals large differences in the results of some thromboelastometry parameters and lack of consistency. Clinicians and scientists should take these inconsistencies into account and focus on parameters with a higher homogeneity such as MCF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Peripheral arterial disease (PAD) is a progressive vascular disease associated with a high risk of cardiovascular morbidity and death. Antithrombotic prevention is usually applied by prescribing the antiplatelet agent aspirin. However, in patients with PAD aspirin fails to provide protection against myocardial infarction and death, only reducing the risk of ischemic stroke. Platelets may play a role in disease development, but this has not been tested by proper mechanistic studies. In the present study, we performed a systematic evaluation of platelet reactivity in whole blood from patients with PAD using two high-throughput assays, i.e. multi-agonist testing of platelet activation by flow cytometry and multi-parameter testing of thrombus formation on spotted microarrays. METHODS Blood was obtained from 40 patients (38 on aspirin) with PAD in majority class IIa/IIb and from 40 age-matched control subjects. Whole-blood flow cytometry and multiparameter thrombus formation under high-shear flow conditions were determined using recently developed and validated assays. RESULTS Flow cytometry of whole blood samples from aspirin-treated patients demonstrated unchanged high platelet responsiveness towards ADP, slightly elevated responsiveness after glycoprotein VI stimulation, and decreased responsiveness after PAR1 thrombin receptor stimulation, compared to the control subjects. Most parameters of thrombus formation under flow were similarly high for the patient and control groups. However, in vitro aspirin treatment caused a marked reduction in thrombus formation, especially on collagen surfaces. When compared per subject, markers of ADP- and collagen-induced integrin activation (flow cytometry) strongly correlated with parameters of collagen-dependent thrombus formation under flow, indicative of a common, subject-dependent regulation of both processes. CONCLUSION Despite of the use of aspirin, most platelet activation properties were in the normal range in whole-blood from class II PAD patients. These data underline the need for more effective antithrombotic pharmacoprotection in PAD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunoassays are essential in the workup of patients with suspected heparin-induced thrombocytopenia. However, the diagnostic accuracy is uncertain with regard to different classes of assays, antibody specificities, thresholds, test variations, and manufacturers. We aimed to assess diagnostic accuracy measures of available immunoassays and to explore sources of heterogeneity. We performed comprehensive literature searches and applied strict inclusion criteria. Finally, 49 publications comprising 128 test evaluations in 15 199 patients were included in the analysis. Methodological quality according to the revised tool for quality assessment of diagnostic accuracy studies was moderate. Diagnostic accuracy measures were calculated with the unified model (comprising a bivariate random-effects model and a hierarchical summary receiver operating characteristics model). Important differences were observed between classes of immunoassays, type of antibody specificity, thresholds, application of confirmation step, and manufacturers. Combination of high sensitivity (>95%) and high specificity (>90%) was found in 5 tests only: polyspecific enzyme-linked immunosorbent assay (ELISA) with intermediate threshold (Genetic Testing Institute, Asserachrom), particle gel immunoassay, lateral flow immunoassay, polyspecific chemiluminescent immunoassay (CLIA) with a high threshold, and immunoglobulin G (IgG)-specific CLIA with low threshold. Borderline results (sensitivity, 99.6%; specificity, 89.9%) were observed for IgG-specific Genetic Testing Institute-ELISA with low threshold. Diagnostic accuracy appears to be inadequate in tests with high thresholds (ELISA; IgG-specific CLIA), combination of IgG specificity and intermediate thresholds (ELISA, CLIA), high-dose heparin confirmation step (ELISA), and particle immunofiltration assay. When making treatment decisions, clinicians should be a aware of diagnostic characteristics of the tests used and it is recommended they estimate posttest probabilities according to likelihood ratios as well as pretest probabilities using clinical scoring tools.