3 resultados para Cardiac valves
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
A 22-year-old man with pre-existing aortic valve disease contracted acute lactobacillus endocarditis six weeks after a dental procedure despite adequate prophylaxis. We discuss the limitations of prophylaxis for infective endocarditis in use until the end of 2008 and describe the new updated guidelines. We also explain the treatment of lactobacillus endocarditis and speculate on possible health risks of the increasing use of lactobacillus-containing dairy products, especially in immune-compromised patients.
Resumo:
Cardiac papillary fibroelastoma is a benign tumor that mainly affects cardiac valves. The tumor has the potential to cause angina and myocardial infarction due to embolization of tumor fragments. We describe a rare case of right coronary artery ostial obstruction by a 12 x 19 mm sized papillary fibroelastoma located in the sinus of Valsalva. The report underlies the importance of echocardiography in diagnosis and intraoperative treatment of this type of cardiac mass.
Resumo:
Objective: Minimizing resection and preserving leaflet tissue has been previously shown to be beneficial for mitral valve function and leaflet kinematics after repair of acute posterior leaflet prolapse in porcine valves. We examined the effects of different additional methods of mitral valve repair (neochordoplasty, ring annuloplasty, edge-to-edge repair and triangular resection) on hemodynamics at different heart rates in an experimental model. Methods: Severe acute P2 prolapse was created in eight porcine mitral valves by resecting the posterior marginal chordae. Valve hemodynamics was quantified under pulsatile conditions in an in vitro heart simulator before and after surgical manipulation. Mitral regurgitation was corrected using four different methods of repair on the same valve: neochordoplasty with expanded polytetrafluoroethylene sutures alone and together with ring annuloplasty, edge-to-edge repair and triangular resection, both with non-restrictive annuloplasty. Residual mitral valve leak, trans-valvular pressure gradients, flow and cardiac output were measured at 60 and 80 beats/min. A validated statistical linear mixed model was used to analyze the effect of treatment. The p values were calculated using a two-sided Wald test. Results: Only neochordoplasty with expanded polytetrafluoroethylene sutures but without ring annuloplasty achieved similar hemodynamics compared to those of the native mitral valve (p range 0.071-0.901). Trans-valvular diastolic pressure gradients were within a physiologic range but significantly higher than those of the native valve following neochordoplasty with ring annuloplasty (p=0.000), triangular resection (p=0.000) and edge-to-edge repair (p=0.000). Neochordoplasty alone was significantly better in terms of hemodynamic than neochordoplasty with a ring annuloplasty (p=0.000). These values were stable regardless of heart rate or ring size. Conclusions: Neochordoplasty without ring annuloplasty is the only repair technique able to achieve almost native physiological hemodynamics after correction of leaflet prolapse in a porcine experimental model of acute chordal rupture.