81 resultados para Calcaneus Tendon

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were to evaluate the anatomic feasibility of medial patellofemoral ligament (MPFL) reconstruction using a part of the adductor magnus tendon and to identify possible risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to describe the tenovaginoscopic approach to the bovine common digital flexor tendon sheath (CDFTS). A comparative anatomical, ultrasonographic and endoscopic study was undertaken using 26 healthy cadaver feet from adult dairy cows. Tenovaginoscopy was performed using a rigid, 30 degrees arthroscope (length 18 cm; outer diameter 4mm) enabling a direct view of the synovial cavity and the following structures: digital flexor tendons, digital annular ligaments, lateral and medial pouches, three mesotendons, the vinculum of the superficial digital flexor tendon, and a slot-shaped opening in the manicaflexoria of the hind feet. Additionally, four clinical cases of septic tenosynovitis treated with lavage under tenovaginoscopic control were examined. Tenovaginoscopy represents a feasible, minimally invasive method for the diagnosis and treatment of septic tenosynovitis of the CDFTS, which allows the degree of alterations of the normal structures to be evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotator cuff lesions are common and the incidence increases with age. After tendon rupture of the rotator cuff, the muscle-tendon unit retracts, which is accompanied by muscle fatty infiltration, atrophy, and interstitial fibrosis of the musculature, thus, fundamentally changing the muscle architecture. These changes are important prognostic factors for the operative rotator cuff reconstruction outcome. Selection of the correct time point for reconstruction as well as the optimal mechanical fixation technique are decisive for successful attachment at the tendon-to-bone insertion site. Thus, knowledge of the pathophysiological processes plays an important role. The goal of this article is to establish a relationship between currently existing evidence with respect to the preoperatively existing changes of the muscle-tendon unit and the choice of the time for the operation and the operative technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-standing rotator cuff tendon tearing is associated with retraction, loss of work capacity, irreversible fatty infiltration, and atrophy of the rotator cuff muscles. Although continuous musculotendinous relengthening can experimentally restore muscular architecture, restoration of atrophy and fatty infiltration is hitherto impossible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to review the diagnosis on MRI and radiography of 24 renal transplant recipients with hip pain suspicious for avascular necrosis and to investigate whether there is an association between kidney transplant patients with end-stage renal disease and symptomatic gluteus minimus and medius tendon abnormality. CONCLUSION: Symptomatic gluteus minimus and medius tendon lesions and abnormalities can occur in renal allograft recipients. The MRI findings of this entity allow an alternative diagnosis in this patient population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic irritation of the iliopsoas tendon is a rare cause of persistent pain after total joint replacement of the hip. In the majority of cases, pain results from a mechanical conflict between the iliopsoas tendon and the anterior edge of the acetabular cup after total hip arthroplasty. Pain can be reproduced by active flexion of the hip and by active raising of the straightened leg. In addition, painful leg raising against resistance and passive hyperextension are suggestive of an irritation of the iliopsoas tendon. Symptoms evolve from a mechanical irritation of the iliopsoas tendon and an oversized or retroverted acetabular cup, screws penetrating into the inner aspect of the ilium, or from bone cement protruding beyond the anterior acetabular rim. The diagnosis may be assumed on conventional radiographs and confirmed by CT scans. Fifteen patients with psoas irritation after total hip replacement are reported on. Eleven patients were treated surgically. The acetabular cup was revised and reoriented with more anteversion in six patients, isolated screws penetrating into the tendon were cut and leveled in three patients, and prominent bone cement in conflict with the tendon was resected once. A partial release of the iliopsoas tendon only was performed in another patient. Follow-up examination (range: 11-89 months) revealed that nine patients were free of pain and two patient had mild residual complaints. Psoas irritation in combination with total hip replacement can be prevented by a correct surgical technique, especially with proper selection of the cup size and insertion of the acetabular cup avoiding a rim position exceeding the level of the anterior acetabular rim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The nonoperative treatment of posterior tibial tendon insufficiency (PTTI) can lead to unsatisfactory functional results. Short-term results are available but the impact on the evolution of the deformity is not known. To address these problems, a new brace for the flexible Stage II deformity was developed, and midterm followup was obtained. MATERIALS AND METHOD: In a prospective case series, eighteen patients (mean age 64.2 years; range, 31 to 82; four male, 14 female) with flexible Stage II PTTI were fitted with the new custom-molded foot orthosis. At latest followup of a mean of 61.4 (range, 20 to 87) months, functional results were assessed with the AOFAS ankle hindfoot score and clinical or radiographic progression was recorded. RESULTS: The score improved significantly from a mean of 56 points (range, 20 to 64) to a mean of 82 points (range, 64 to 100, p < 0.001). Three patients (3/18, 16%) had a clinical progression to a fixed deformity (Stage III) and a radiographic increase of their deformity. All the other patients were satisfied with the brace's comfort and noted an improvement in their mobility. Complications were seen in three patients (3/18, 16%), and consisted of the development of calluses. CONCLUSION: The "shell brace" is a valuable option for nonoperative treatment of the flexible Stage II PTTI. Hindfoot flexibility was conserved throughout the observation period in all but three patients. Functional outcome and patient acceptance was above average. Problems were few, and closely associated with a progression to a fixed, Stage III deformity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soft tissue coverage of the medial ankle and foot remains a difficult, challenging, and often frustrating problem to patients as well as surgeons. To our knowledge, the abductor hallucis muscle flap is not frequently used and only a few well documented cases were found in literature. The purpose of this paper is to report and to present the long-term results of a series of four patients who underwent reconstruction of foot and ankle defects with the abductor hallucis muscle flap.In two cases, the abductor hallucis muscle flap was transposed in combination with a medialis pedis flap to cover a medial ankle defect, whereas in another case it was combined with a medial plantar flap. In this latter case, the muscle flap served to fill up a calcaneal dead space after osteomyelitis debridement, whereas the cutaneous flap was used to replace debrided skin at the heel. The abductor hallucis flap was used as a distally-based turnover flap to cover a large forefoot defect in a fourth case. Follow-up period ranged between 18 and 64 months (mean 43.3). In the early postoperative period, two flaps healed completely In two patients marginal flap necrosis occurred which was subsequently skin grafted. No donor-site complication occurred in any of the patients. In all cases, protective sensation of the skin was satisfactory as early as 6 months. In two cases mild hyperkeratosis at the skin graft border to the sole skin (non-weight bearing area of medial plantar and medialis pedis flap donor site) was present, but probably related to poor foot care. All patients were fully mobile as early as 3 months after treatment. In the long-term follow-up (43.3 months), all flaps provided with durable coverage. Functional gait deficit due to consumtion of the abductor hallucis muscle was not apparent.Our long-term results demonstrated that the abductor hallucis muscle flap is a versatile, and reliable flap suitable for the reconstruction of foot and ankle defects. Utilizing the abductor hallucis muscle as a pedicled flap (distally or proximally-based) with or without conjoined regional fasciocutaneous flaps offers a successful and durable alternative to microsurgical tree flaps for small to moderate defects over the calcaneus region, medial ankle, medial foot, and forefoot with exposed bone, tendon, or joint.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 70-year-old man known for recurrent abdominal gastrointestinal stroma tumor presented with a suspicious peritoneal mass demonstrated by an abdominal CT scan. Whole-body PET showed focal FDG uptake in the right hip, whereas the peritoneal mass was FDG negative. Histologic work-up of the PET positive lesion surprisingly revealed a giant cell tumor of the tendon sheath. The benignity of the peritoneal mass was confirmed by its disappearance in repeated CT scans. In general, focally increased FDG uptake should be subject to further investigations, especially in localizations that are not consistent with typical metastatic pathways of the former primary tumor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skeletal muscle atrophy and fatty infiltration develop after tendon tearing. The extent of atrophy serves as one prognostic factor for the outcome of surgical repair of rotator cuff tendon tears. We asked whether mRNA of genes involved in regulation of degradative processes leading to muscle atrophy, ie, FOXOs, MSTN, calpains, cathepsins, and transcripts of the ubiquitin-proteasome pathway, are overexpressed in the supraspinatus muscle in patients with and without rotator cuff tears. We evaluated biopsy specimens collected during surgery of 53 consecutive patients with different sizes of rotator cuff tendon tears and six without tears. The levels of corresponding gene transcripts in total RNA extracts were assessed by semiquantitative reverse transcriptase-polymerase chain reaction (RT-PCR) analysis. Supraspinatus muscle atrophy was assessed by MRI. The area of muscle tissue (or atrophy), decreased (increased) with increasing tendon tear size. The transcripts of CAPN1, UBE2B, and UBE3A were upregulated more than twofold in massive rotator cuff tears as opposed to smaller tears or patients without tears. These atrophy gene products may be involved in cellular processes that impair functional recovery of affected muscles after surgical rotator cuff repair. However, the damaging effects of gene products in their respective proteolytic processes on muscle structures and proteins remains to be investigated.