297 resultados para CT angiography
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Non-contrast post-mortem computed tomography (pm-CT) is useful in the evaluation of bony pathologies, whereas minimally invasive pm-CT-angiography allows for the detection of subtle vascular lesions. We present a case of an accidentally self-inflicted fatal bullet wound to the chest where pm-CT-angiography revealed a small laceration of the anterior interventricular branch of the left coronary artery and a tiny disruption of the right ventricle with pericardial and pleural effusion. Subsequent autopsy confirmed our radiological findings. Post-mortem CT-angiography has a great potential for the detection of vascular lesions and can be considered equivalent to autopsy for selected cases in forensic medicine.
Resumo:
We present a case of an individual who stabbed himself through the heart with a large knife. Post mortem computed tomography (CT) and CT-angiography were used to assess the stab channel and to reconstruct the sequence of events. After penetrating injuries to the chest, both the intra-thoracic organs and the injury causing instrument may shift (e.g. from pnemothorax) and render forensic reconstructions more challenging. This case report illustrates the potentials and the pitfalls of CT for the reconstruction of penetrating injures to the chest.
Resumo:
To study the effect of a nonlinear noise filter on the detection of simulated endoleaks in a phantom with 80- and 100-kVp multidetector computed tomographic (CT) angiography.
Resumo:
This review summarizes current evidence based on pertinent literature on low-dose computed tomography angiography (CTA) of the body. Various strategies for optimizing CTA protocols with the aim to lower the radiation dose while maintaining the diagnostic accuracy of the examination are summarized. To date, various publications have demonstrated that CTA of the body can be performed at a low radiation dose while providing high quality information. Nevertheless, a number of questions still need to be answered, including the optimal combination of tube voltage and tube current settings, as well as the appropriate protocol parameters in relation to the body physiognomy and the specific body region imaged.
Resumo:
To assess the effect of beam hardening on arterial enhancement in thoracoabdominal computed tomographic (CT) angiography in various body sizes in a phantom and in a clinical study.
Resumo:
CT pulmonary angiography is the currently accepted standard in ruling out acute pulmonary embolism. Issues of radiation dose received by patients via CT have been extensively disputed by radiologists and reported by the media. In recent years there has been considerable research performed to find ways for reducing radiation exposure from CT. Herein, we will discuss specific measures that have been shown to be valuable for CT pulmonary angiography. The limitations and the potential benefits of reduced CT peak tube kilovoltage will be detailed as this method is capable of reducing both radiation exposure and iodine load to the patient simultaneously. We discuss some of the emerging tools, which will hopefully play a significant role in wider acceptance of low-dose CT pulmonary angiography protocols.
Resumo:
To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs).
Resumo:
Purpose:To determine the potential of minimally invasive postmortem computed tomographic (CT) angiography combined with image-guided tissue biopsy of the myocardium and lungs in decedents who were thought to have died of acute chest disease and to compare this method with conventional autopsy as the reference standard.Materials and Methods:The responsible justice department and ethics committee approved this study. Twenty corpses (four female corpses and 16 male corpses; age range, 15-80 years), all of whom were reported to have had antemortem acute chest pain, were imaged with postmortem whole-body CT angiography and underwent standardized image-guided biopsy. The standard included three biopsies of the myocardium and a single biopsy of bilateral central lung tissue. Additional biopsies of pulmonary clots for differentiation of pulmonary embolism and postmortem organized thrombus were performed after initial analysis of the cross-sectional images. Subsequent traditional autopsy with sampling of histologic specimens was performed in all cases. Thereafter, conventional histologic and autopsy reports were compared with postmortem CT angiography and CT-guided biopsy findings. A Cohen k coefficient analysis was performed to explore the effect of the clustered nature of the data.Results:In 19 of the 20 cadavers, findings at postmortem CT angiography in combination with CT-guided biopsy validated the cause of death found at traditional autopsy. In one cadaver, early myocardial infarction of the papillary muscles had been missed. The Cohen κ coefficient was 0.94. There were four instances of pulmonary embolism, three aortic dissections (Stanford type A), three myocardial infarctions, three instances of fresh coronary thrombosis, three cases of obstructive coronary artery disease, one ruptured ulcer of the ascending aorta, one ruptured aneurysm of the right subclavian artery, one case of myocarditis, and one pulmonary malignancy with pulmonary artery erosion. In seven of 20 cadavers, CT-guided biopsy provided additional histopathologic information that substantiated the final diagnosis of the cause of death.Conclusion:Postmortem CT angiography combined with image-guided biopsy, because of their minimally invasive nature, have a potential role in the detection of the cause of death after acute chest pain.© RSNA, 2012.
Resumo:
The purpose of this study was to simulate pulmonary emboli (PE) and image quality at low tube energy and reduced contrast material volume in normal-dose pulmonary CT angiography (CTA) images and to analyze the diagnostic accuracy with normal- and low-dose pulmonary CTA.
Resumo:
The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) quantifies the extent of early ischemic changes in the posterior circulation with a 10-point grading system. We hypothesized that pc-ASPECTS applied to CT angiography source images predicts functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS).
Resumo:
The effect of varying injection rates of a saline chaser on aortic enhancement in computed tomography (CT) angiography was determined. Single-level, dynamic CT images of a physiological flow phantom were acquired between 0 and 50 s after initiation of contrast medium injection. Four injection protocols were applied with identical contrast medium administration (150 ml injected at 5 ml/s). For baseline protocol A, no saline chaser was applied. For protocols B, C, and D, 50 ml of saline was injected at 2.5 ml/s, 5 ml/s, and 10 ml/s, respectively. Injecting the saline chaser at twice the rate as the contrast medium yielded significantly higher peak aortic enhancement values than injecting the saline at half or at the same rate as the contrast medium (P < 0.05). Average peak aortic enhancement (HU) measured 214, 214, 218, and 226 for protocols A, B, C, and D, respectively. The slower the saline-chaser injection rate, the longer the duration of 90% peak enhancement: 13.6, 12.2, and 11.7 s for protocols B, C, and D, respectively (P > 0.05). In CT angiography, saline chaser injected at twice the rate as the contrast medium leads to increased peak aortic enhancement and saline chaser injected at half the rate tends towards prolonging peak aortic enhancement plateau.
Resumo:
OBJECTIVE: The objective of our study was to establish a standardized procedure for postmortem whole-body CT-based angiography with lipophilic and hydrophilic contrast media solutions and to compare the results of these two methods. MATERIALS AND METHODS: Minimally invasive postmortem CT angiography was performed on 10 human cadavers via access to the femoral blood vessels. Separate perfusion of the arterial and venous systems was established with a modified heart-lung machine using a mixture of an oily contrast medium and paraffin (five cases) and a mixture of a water-soluble contrast medium with polyethylene glycol (PEG) 200 in the other five cases. Imaging was executed with an MDCT scanner. RESULTS: The minimally invasive femoral approach to the vascular system provided a good depiction of lesions of the complete vascular system down to the level of the small supplying vessels. Because of the enhancement of well-vascularized tissues, angiography with the PEG-mixed contrast medium allowed the detection of tissue lesions and the depiction of vascular abnormalities such as pulmonary embolisms or ruptures of the vessel wall. CONCLUSION: The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues (cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.
Resumo:
OBJECTIVE: We explored the potential for patients with proven venous thromboembolism or pulmonary embolism (PE) to have occult malignancies detected during the same CT examination. To verify this, we compared the presence of occult malignancies identified on pulmonary artery CT angiography (CTA) and CT venography (CTV) when venous thromboembolism (VTE) was present. SUBJECTS AND METHODS: Pulmonary artery CTA combined with CTV was performed on a 16-MDCT scanner on 186 adult patients suspected of having pulmonary embolism without any known malignancies. CTV was performed from the diaphragm to the knee 180 seconds after CTA. Two radiologists evaluated the presence of VTE, that is PE or deep venous thrombosis (DVT), and tumor lesions on both examinations in consensus. The malignant nature of the possibly identified tumors was confirmed by pathologic examination. RESULTS: VTE was found in 49 patients (26%). Malignant tumors were detected in 24 patients (13%). Eleven patients with malignant tumors had VTE (46% of patients with malignant tumors; 22% with VTE and 6% of all patients). There was correlation with presence of malignancies between both and DVT and DVT associated with PE but not between presence of malignancies and PE only. Patients with DVT and those with DVT associated with PE had a risk ratio of 3.2 and 3.3, respectively, for having a malignant tumor discovered simultaneously. CONCLUSION: A high number of malignant tumors can be incidentally discovered on pulmonary artery CTA, even more so with additional CTV. Radiologists should scrutinize scans to pick up unknown malignancies, especially in patients with identified VTE.