2 resultados para COUNTER-CURRENT CHROMATOGRAPHY

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Sudden infant death syndrome (SIDS) is a leading cause of death during the first 6 months after birth. About 5% to 10% of SIDS may stem from cardiac channelopathies such as long-QT syndrome. We recently implicated mutations in alpha1-syntrophin (SNTA1) as a novel cause of long-QT syndrome, whereby mutant SNTA1 released inhibition of associated neuronal nitric oxide synthase by the plasma membrane Ca-ATPase PMCA4b, causing increased peak and late sodium current (I(Na)) via S-nitrosylation of the cardiac sodium channel. This study determined the prevalence and functional properties of SIDS-associated SNTA1 mutations. METHODS AND RESULTS Using polymerase chain reaction, denaturing high-performance liquid chromatography, and DNA sequencing of SNTA1's open reading frame, 6 rare (absent in 800 reference alleles) missense mutations (G54R, P56S, T262P, S287R, T372M, and G460S) were identified in 8 (approximately 3%) of 292 SIDS cases. These mutations were engineered using polymerase chain reaction-based overlap extension and were coexpressed heterologously with SCN5A, neuronal nitric oxide synthase, and PMCA4b in HEK293 cells. I(Na) was recorded using the whole-cell method. A significant 1.4- to 1.5-fold increase in peak I(Na) and 2.3- to 2.7-fold increase in late I(Na) compared with controls was evident for S287R-, T372M-, and G460S-SNTA1 and was reversed by a neuronal nitric oxide synthase inhibitor. These 3 mutations also caused a significant depolarizing shift in channel inactivation, thereby increasing the overlap of the activation and inactivation curves to increase window current. CONCLUSIONS Abnormal biophysical phenotypes implicate mutations in SNTA1 as a novel pathogenic mechanism for the subset of channelopathic SIDS. Functional studies are essential to distinguish pathogenic perturbations in channel interacting proteins such as alpha1-syntrophin from similarly rare but innocuous ones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The improvement and performance of a micellar electrokinetic capillary chromatography assay for cefepime in human serum and plasma with a 50 μm id fused-silica capillary elongated from 40 to 60 cm is reported. Sample preparation with dodecylsulfate protein precipitation at pH 4.5, the pH 9.1 separation medium and the applied voltage were as reported previously[16]. The change resulted in a significant lower current, higher resolution and increased detection time intervals. The performance of the assay with multi-level internal calibration was assessed with calibration and control samples. Quality assurance data of a two year period assessed under the new conditions demonstrated the robustness of the assay. In serum samples of patients who received both cefepime and sulfamethoxazole, cefepime could not be detected due to the inseparability of the two compounds. The presence of an interference can be recognized by an increased peak width (width > 0.2 min), the appearance of a shoulder or an unresolved double peak. The patient data gathered during a three year period reveal that introduction of therapeutic drug monitoring led to a 50% reduction of the median drug level. The data suggest that therapeutic drug monitoring can help to minimize the risk of major adverse reactions and to increase drug safety on an individual basis. This article is protected by copyright. All rights reserved.