248 resultados para CORONARY ARTERY BYPASS GRAFTING

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of radial artery conduits in coronary artery bypass grafting (CABG) surgery is associated with improved long-term patency and patient survival rates as compared with saphenous vein conduits. Despite increasing popularity, relative incidence of local harvest-site complications and subjective perception of adverse long-term sequelae remain poorly described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The perioperative risk for redo surgical aortic valve replacement (S-AVR) in patients with severe aortic stenosis and prior coronary artery bypass grafting (CABG) is increased. Transcatheter aortic valve implantation (TAVI) represents an alternative. We assessed the perioperative and mid-term clinical outcome of patients undergoing S-AVR or TAVI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Minimal extracorporeal circulation (MECC) is a promising perfusion technology, taking the advantage of an ECC while having a significantly reduced priming volume. We analyzed the actual possible benefits of using MECC in patients undergoing CABG procedures and compared the results with conventional extracorporeal circulation (CECC). METHODS: One thousand fifty-three consecutive patients underwent CABG surgery using the MECC perfusion technique. Subgroup analyses focused on perioperative myocardial markers (cardiac troponin I [cTnI]), incidence of atrial fibrillation (AF), and perioperative evaluation of inflammatory markers and data were compared with those of patients who underwent CABG using CECC. A propensity score analysis was performed. RESULTS: Patient characteristics and distribution of EuroSCORE risk were similar in both groups. Severity of coronary artery disease and extent of revascularization were also comparable in both groups (number of distal anastomoses: 3.2 +/- 1.1 in CECC vs 3.2 +/- 0.9 in MECC; p = not significant [ns]). The cTnI was significantly lower in the MECC group (11.0 +/- 10.8 microg/L in MECC vs 24.7 +/- 25.3 microg/L in CECC; p < 0.05). Incidence of AF was 11.1% in MECC and 39.0% in CECC (p < 0.05). Inflammatory markers (interleukin-6, SC5b-9) were lower in MECC patients (p < 0.05). Propensity score analysis confirmed faster recovery in MECC patients and lower incidence of AF. CONCLUSIONS: Minimal extracorporeal circulation is a safe perfusion technique for CABG and may therefore concurrence OPCAB and traditional CABG under CECC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most recently discussion about the optimal treatment for different subsets of patients suffering from coronary artery disease has re-emerged, mainly because of the uncertainty caused by doctors and patients regarding the phenomenon of unpredictable early and late stent thrombosis. Surgical revascularization using multiple arterial bypass grafts has repeatedly proven its superiority compared to percutaneous intervention techniques, especially in patients suffering from left main stem disease and coronary 3-vessels disease. Several prospective randomized multicenter studies comparing early and mid-term results following PCI and CABG have been really restrictive, with respect to patient enrollment, with less than 5% of all patients treated during the same time period been enrolled. Coronary artery bypass grafting allows the most complete revascularization in one session, because all target coronary vessels larger than 1 mm can be bypassed in their distal segments. Once the patient has been turn-off for surgery, surgeons have to consider the most complete arterial revascularization in order to decrease the long-term necessity for re-revascularization; for instance patency rate of the left internal thoracic artery grafted to the distal part left anterior descending artery may be as high as 90-95% after 10 to 15 years. Early mortality following isolated CABG operation has been as low as 0.6 to 1% in the most recent period (reports from the University Hospital Berne and the University Hospital of Zurich); beside these excellent results, the CABG option seems to be less expensive than PCI with time, since the necessity for additional PCI is rather high following initial PCI, and the price of stent devices is still very high, particularly in Switzerland. Patients, insurance and experts in health care should be better and more honestly informed concerning the risk and costs of PCI and CABG procedures as well as about the much higher rate of subsequent interventions following PCI. Team approach for all patients in whom both options could be offered seems mandatory to avoid unbalanced information of the patients. Looking at the recent developments in transcatheter valve treatments, the revival of cardiological-cardiosurgical conferences seems to a good option to optimize the cooperation between the two medical specialties: cardiology and cardiac surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Peak levels of troponin T (TnT) reliably predict morbidity and mortality after cardiac surgery. However, the therapeutic window to manage CABG-related in-hospital complications may close before the peak is reached. We investigated whether early TnT levels correlate as well with complications after coronary artery bypass grafting (CABG) surgery. METHODS A 12 month consecutive series of patients undergoing elective isolated CABG procedures (mini-extra-corporeal circuit, Cardioplegic arrest) was analyzed. Logistic regression modeling was used to investigate whether TnT levels 6 to 8 hours after surgery were independently associated with in-hospital complications (either post-operative myocardial infarction, stroke, new-onset renal insufficiency, intensive care unit (ICU) readmission, prolonged ICU stay (>48 hours), prolonged need for vasopressors (>24 hours), resuscitation or death). RESULTS A total of 290 patients, including 36 patients with complications, was analyzed. Early TnT levels (odds ratio (OR): 6.8, 95% confidence interval (CI): 2.2-21.4, P=.001), logistic EuroSCORE (OR: 1.2, 95%CI: 1.0-1.3, P=.007) and the need for vasopressors during the first 6 postoperative hours (OR: 2.7, 95%CI: 1.0-7.1, P=.05) were independently associated with the risk of complications. With consideration of vasopressor use during the first 6 postoperative hours, the sum of specificity (0.958) and sensitivity (0.417) of TnT for subsequent complications was highest at a TnT cut-off value of 0.8 ng/mL. CONCLUSION Early TnT levels may be useful to guide ICU management of CABG patients. They predict clinically relevant complications within a potential therapeutic window, particularly in patients requiring vasopressors during the first postoperative hours, although with only moderate sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary artery bypass grafting (CABG) by electroencephalogram P300 wave event-related potentials and number connection test (NCT) as metrics of cognitive function. METHODS Cognitive brain function was assessed in 31 patients in 2013 with a mean age of 65 years [standard deviation (SD) 10] undergoing CABG by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds) directly prior to intervention, 7 days after and 3 months later. Number connection test, serving as method of control, was performed simultaneously in all patients. RESULTS Seven days following CABG, cognitive P300 evoked potentials were comparable with preoperative baseline values [vertex (Cz) 376 (SD 11) ms vs 378 (18) ms, P = 0.39; frontal (Fz) 377 (11) vs 379 (21) ms, P = 0.53]. Cognitive brain function at 3 months was compared with baseline values [(Cz) 376 (11) ms vs 371 (14 ms) P = 0.09; (Fz) 377 (11) ms vs 371 (15) ms, P = 0.04]. Between the first postoperative measurement and 3 months later, significant improvement was observed [(Cz) 378 (18) ms vs 371 (14) ms, P = 0.03; (Fz) 379 (21) vs 371 (15) ms, P = 0.02]. Similar clearly corresponding patterns could be obtained via the number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (P = 0.05) and (Fz) results (P = 0.04). CONCLUSIONS MECC does not adversely affect cognitive brain function after CABG. Additionally, these patients experience a substantial significant cognitive improvement after 3 months, evidentiary proving that the concept of MECC ensures safety and outcome in terms of brain function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Antifibrinolytics have been used for 2 decades to reduce bleeding in cardiac surgery. MDCO-2010 is a novel, synthetic, serine protease inhibitor. We describe the first experience with this drug in patients. METHODS In this phase II, double-blind, placebo-controlled study, 32 patients undergoing isolated primary coronary artery bypass grafting with cardiopulmonary bypass were randomly assigned to 1 of 5 increasing dosage groups of MDCO-2010. The primary aim was to evaluate pharmacokinetics (PK) with assessment of plasmatic concentrations of the drug, short-term safety, and tolerance of MDCO-2010. Secondary end points were influence on coagulation, chest tube drainage, and transfusion requirements. RESULTS PK analysis showed linear dosage-proportional correlation between MDCO-2010 infusion rate and PK parameters. Blood loss was significantly reduced in the 3 highest dosage groups compared with control (P = 0.002, 0.004 and 0.011, respectively). The incidence of allogeneic blood product transfusions was lower with MDCO-2010 4/24 (17%) vs 4/8 (50%) in the control group. MDCO-2010 exhibited dosage-dependent antifibrinolytic effects through suppression of D-dimer generation and inhibition of tissue plasminogen activator-induced lysis in ROTEM analysis as well as anticoagulant effects demonstrated by prolongation of activated clotting time and activated partial thromboplastin time. No systematic differences in markers of end organ function were observed among treatment groups. Three patients in the MDCO-2010 groups experienced serious adverse events. One patient experienced intraoperative thrombosis of venous grafts considered possibly related to the study drug. No reexploration for mediastinal bleeding was required, and there were no deaths. CONCLUSIONS This first-in-patient study demonstrated dosage-proportional PK for MDCO-2010 and reduction of chest tube drainage and transfusions in patients undergoing primary coronary artery bypass grafting. Antifibrinolytic and anticoagulant effects were demonstrated using various markers of coagulation. MDCO-2010 was well tolerated and showed an acceptable initial safety profile. Larger multi-institutional studies are warranted to further investigate the safety and efficacy of this compound.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Coronary artery bypass grafting (CABG) using extracorporeal circulation (ECC) is still the gold standard. However, alternative techniques have been developed to avoid ECC and its potential adverse effects. These encompass minimal extracorporeal circulation (MECC) or off-pump coronary artery bypass grafting (OPCAB). However, the prevailing potential benefits when comparing MECC and OPCABG are not yet clearly established. METHODS In this retrospective study we investigated the potential benefits of MECC and OPCABG in 697 patients undergoing CABG. Of these, 555 patients had been operated with MECC and 142 off-pump. The primary endpoint was Troponin T level as an indicator for myocardial damage. RESULTS Study groups were not significantly different in general. However, patients undergoing OPCABG were significantly older (65.01 years ± 9.5 vs. 69.39 years ± 9.5; p value <0.001) with a higher Logistic EuroSCORE I (4.92% ± 6.5 vs. 5.88% ± 6.8; p value = 0.017). Operating off pump significantly reduced the need for intra-operative blood products (0.7% vs. 8.6%; p-value <0.001) and the length of stay in the intensive care unit (ICU) (2.04 days ± 2.63 vs. 2.76 days ± 2.79; p value <0.001). Regarding other blood values a significant difference could not be found in the adjusted calculations. The combined secondary endpoint, major cardiac or cerebrovascular events (MACCE), was equal in both groups as well. CONCLUSIONS Coronary artery bypass grafting using MECC or OPCABG are two comparable techniques with advantages for OPCABG regarding the reduced need for intra-operative blood products and shorter length of stay in the ICU. However serological values and combined endpoint MACCE did not differ significantly in both groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Minimized Extracorporeal Circulation does not impair cognitive brain function after coronary artery bypass grafting – – Objectives – Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary bypass grafting (CABG) by Electroencephalogram (EEG) P 300 wave event related potentials (ERP) and number connection test ( NCT) as metrics of cognitive function. – – Methods – Cognitive brain function was assessed in 31 patients with a mean age of 65y (Standard Deviation/SD 10) undergoing coronary artery bypass grafting (CABG) by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds [ms]) directly prior to intervention, 7 days after and 3 month later. Number connection test (NCT), serving as method of control, was performed simultaneously in all patients. – – Results – Seven days following CABG, cognitive P300 evoked potentials were comparable to preoperative baseline values (vertex [Cz] 376 (SD 11) ms vs. 378 (18) ms, p=0.39, frontal [Fz] 377 (11) vs. 379 (21) ms, p=0.53). Cognitive brain function showed at 3 months compared to baseline values ([Cz] 376 (11) ms vs. 371 (14 ms) p=0.09, [Fz] 377 (11) ms vs. 371 (15) ms, p=0.04. Between the first postoperative measurement and 3 months later, significant improvement was observed ([Cz] 378 (18) ms vs. 371 (14) ms, p=0.03, [Fz] 379 (21) vs. 371 (15) ms, p=0.02). Similar clearly corresponding patterns could be obtained via number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (p = 0.05) and (Fz) results (p = 0.04). – – Conclusions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary embolism is very rarely reported early after cardiac surgery, most probably due to full heparinisation during cardiopulmonary bypass. We report a 66-year-old man without thromboembolic history who presented three days after a coronary artery bypass grafting procedure with acute dyspnoea and haemodynamic instability. A CT scan confirmed paracentral bilateral pulmonary embolism requiring an urgent and successful embolectomy. Review of the literature confirms that pulmonary embolism may occur in up to 3% of post-cardiopulmonary bypass patients. The possibility of pulmonary embolism must be taken into consideration in post-cardiopulmonary bypass patients with acute onset of chest pain and respiratory insufficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Resternotomy for aortic valve replacement in patients with previous coronary artery bypass grafting and an internal mammary artery graft may be a surgical problem. Thus, we are exploring the effect of using rapid prototyping techniques for surgical planning and intraoperative orientation during aortic valve replacement after previous coronary artery bypass grafting (CABG). DESCRIPTION As a proof of concept, we studied a patient who had undergone CABG 5 years earlier. At that time the patient received a left internal mammary artery graft to the left anterior descending artery and a venous graft to the right coronary artery. Now the patient required aortic valve replacement due to symptomatic aortic valve stenosis. The left internal mammary artery bypass and the right coronary artery bypass were patent and showed good flow in the angiography. The patient was examined by 128-slice computed tomography. The image data were visualized and reconstructed. Afterwards, a replica showing the anatomic structures was fabricated using a rapid prototyping machine. EVALUATION Using data derived from 128-slice computed tomography angiography linked to proprietary software, we were able to create three-dimensional reconstructions of the vascular anatomy after the previous CABG. The models were sterilized and taken to the operating theatre for orientation during the surgical procedure. CONCLUSIONS Stereolithographic replicas are helpful for choosing treatment strategies in surgical planning and for intraoperative orientation during reoperations of patients with previous CABG.