125 resultados para COMPRESSION STANDARD

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this open, prospective, randomised, controlled trial we compared three CPR feedback devices (PocketCPR, CPRmeter, iPhone app PocketCPR) with standard BLS without feedback in a simulated scenario. 240 trained medical students performed single rescuer BLS on a manikin for 8min. Effective compression (compressions with correct depth, pressure point and sufficient decompression) as well as compression rate, flow time fraction and ventilation parameters were compared between the four groups. RESULTS Study participants using the PocketCPR performed 17±19% effective compressions compared to 32±28% with CPRmeter, 25±27% with the iPhone app PocketCPR, and 35±30% applying standard BLS (PocketCPR vs. CPRmeter p=0.007, PocketCPR vs. standard BLS p=0.001, others: ns). PocketCPR and CPRmeter prevented a decline in effective compression over time, but overall performance in the PocketCPR group was considerably inferior to standard BLS. Compression depth and rate were within the range recommended in the guidelines in all groups. CONCLUSION While we found differences between the investigated CPR feedback devices, overall BLS quality was suboptimal in all groups. Surprisingly, effective compression was not improved by any CPR feedback device compared to standard BLS. All feedback devices caused substantial delay in starting CPR, which may worsen outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing. Study design In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3 mm gap at the osteotomy site). One half of each group (6 sheep) was monitored for 6 weeks, and the other half (6 sheep) where followed for 12 weeks. Methods X-rays at 3, 6, 9 and 12 weeks were performed to monitor the healing process. After sacrifice operated tibiae were tested biomechanically for nondestructive torsion and compared to the tibia of the healthy opposite side. After testing specimens were processed for microradiography, histology, histomorphometry and assessment of calcium deposition by fluorescence microscopy. Results In all groups bone healing occurred without complications. Stiffness in biomechanical testing showed a tendency for higher values in G2 but results were not statistically significant. Values for G5 were significantly lower after 6 weeks, but after 12 weeks values had improved to comparable results. For all groups, except G3, stiffness values improved between 6 and 12 weeks. Histomorphometrical data demonstrate endosteal callus to be more marked in G2 at 6 weeks. Discussion and conclusion All five configurations resulted in undisturbed bone healing and are considered safe for clinical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date, obesity affects a substantial population in industrialised countries. Due to the increased awareness of obesity-related morbidity, efficient dietary regimens and the recent successes with bariatric surgery, there is now a high demand for body contouring surgery to correct skin abundancies after massive weight loss. The known risks for this type of surgery are mainly wound-healing complications, and, more rarely, thromboembolic or respiratory complications. We present two female patients (23 and 39 years of age) who, in spite of standard positioning and precautions, developed sciatic neuropathy after combined body contouring procedures, including abdominoplasty and inner thigh lift. Complete functional loss of the sciatic nerve was found by clinical and electroneurographic examination on the left side in patient one and bilaterally in patient two. Full nerve conductance recovery was obtained after 6 months in both patients. Although the occurrence of spontaneous neuropathies after heavy weight loss is well documented, this is the first report describing the appearance of such a phenomenon following body contouring surgery. One theoretical explanation may be the compression of the nerve during the semirecumbent positioning combined with hip flexion and abduction, which was required for abdominal closure and simultaneous access to the inner thighs. We advise to avoid this positioning and to include the risk of sciatic neuropathy in the routine preoperative information of patients scheduled for body contouring surgery after heavy weight loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. METHODS: A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). RESULTS: Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P < .001 vs .010). Quality of life showed no difference between the treatment groups. In both groups, pain at 90 days had decreased by half, independent of completion of healing. Physical, social, and psychic impairment improved significantly in patients with healed ulcers only. CONCLUSION: Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was not different from that of compression with bandages. Both treatments alleviated pain promptly. Quality of life was improved only in patients whose ulcers had healed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate retrospectively in patients with Crohn's disease (CD) if magnetic resonance (MR) motility alterations correlate with CD typical lesions leading to an increased detection rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose was to investigate the in vivo effects of unloading and compression on T1-Gd relaxation times in healthy articular knee cartilage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Animal models provide a basis for clarifying the complex pathogenesis of delayed cerebral vasospasm (DCVS) and for screening of potential therapeutic approaches. Arbitrary use of experimental parameters in current models can lead to results of uncertain relevance. The aim of this work was to identify and analyze the most consistent and feasible models and their parameters for each animal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background There is concern that non-inferiority trials might be deliberately designed to conceal that a new treatment is less effective than a standard treatment. In order to test this hypothesis we performed a meta-analysis of non-inferiority trials to assess the average effect of experimental treatments compared with standard treatments. Methods One hundred and seventy non-inferiority treatment trials published in 121 core clinical journals were included. The trials were identified through a search of PubMed (1991 to 20 February 2009). Combined relative risk (RR) from meta-analysis comparing experimental with standard treatments was the main outcome measure. Results The 170 trials contributed a total of 175 independent comparisons of experimental with standard treatments. The combined RR for all 175 comparisons was 0.994 [95% confidence interval (CI) 0.978–1.010] using a random-effects model and 1.002 (95% CI 0.996–1.008) using a fixed-effects model. Of the 175 comparisons, experimental treatment was considered to be non-inferior in 130 (74%). The combined RR for these 130 comparisons was 0.995 (95% CI 0.983–1.006) and the point estimate favoured the experimental treatment in 58% (n = 76) and standard treatment in 42% (n = 54). The median non-inferiority margin (RR) pre-specified by trialists was 1.31 [inter-quartile range (IQR) 1.18–1.59]. Conclusion In this meta-analysis of non-inferiority trials the average RR comparing experimental with standard treatments was close to 1. The experimental treatments that gain a verdict of non-inferiority in published trials do not appear to be systematically less effective than the standard treatments. Importantly, publication bias and bias in the design and reporting of the studies cannot be ruled out and may have skewed the study results in favour of the experimental treatments. Further studies are required to examine the importance of such bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ACCESS trial examined the 12-month effectiveness of continuous therapeutic assertive community treatment (ACT) as part of integrated care compared to standard care in a catchment area comparison design in patients with schizophrenia spectrum disorders treated with quetiapine immediate release.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fetal echocardiography was initially used to diagnose structural heart disease, but recent interest has focused on functional assessment. Effects of extracardiac conditions on the cardiac function such as volume overload (in the recipient in twin-twin transfusion syndrome), a hyperdynamic circulation (arterio-venous malformation), cardiac compression (diaphragmatic hernia, lung tumours) and increased placental resistance (intrauterine growth restriction and placental insufficiency) can be studied by ultrasound and may guide decisions for intervention or delivery. A variety of functional tests can be used, but there is no single clinical standard. For some specific conditions, however, certain tests have shown diagnostic value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this pilot investigation was to evaluate the utility and precision of already existing limited cone-beam computed tomography (CBCT) scans in measuring the endodontic working length, and to compare it with standard clinical procedures.