49 resultados para CHOROIDAL FISSURE
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
It is unclear whether anti-VEGF monotherapy in age-related macular degeneration (AMD) achieves morphologic CNV regression or only stops further CNV growth. In this study, spectral domain-optical coherence tomography (SD-OCT) was used to image CNV structure before and after anti-VEGF treatment.
Resumo:
To compare the efficacy and safety of same-day verteporfin photodynamic therapy (PDT) and intravitreal ranibizumab combination treatment versus ranibizumab monotherapy in neovascular age-related macular degeneration.
Resumo:
External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described.
Resumo:
This study investigated the structure of the fissure fundus on occlusal surfaces with respect to the detection of possible irregularities below the enamel-dentin junction (EDJ). Occlusal surfaces were examined by micro-computed tomography (µCT). In total, 203 third molars with clinically sound occlusal fissures or non-cavitated lesions were selected. All specimens were scanned with µCT. Subsequently, each tooth was sectioned, and each slice was investigated by stereomicroscopy. In 7 of 203 molars (3.4%), demarcated radiolucencies below the EDJ were detected by µCT. These defects were obviously of non-carious origin, because the µCT images revealed no gradient of demineralization in the dentin. In all cases, a direct pathway between the oral cavity and the dentin was evident. The comparison of the µCT sites with conventional histological images also revealed defects in the dentin. These results demonstrate that demarcated radiolucencies below the EDJ may not necessarily be caries lesions according to µCT images and may be classified as possible developmental irregularities. To avoid misinterpreting µCT data, dental researchers should carefully consider this condition when analyzing µCT images. The clinical significance of this finding is that these defects may predispose molar teeth to early-onset caries in occlusal pits and fissures.
Resumo:
We present an unusual case of polypoidal choroidal vasculopathy (PCV) lying above the retinal pigment epithelium (RPE) in a 60-year-old Caucasian female. PCV lesions are typically located beneath the RPE layer. However, they may rarely lie above the level of the RPE due to a discontinuity in the RPE and Bruch's membrane.
Resumo:
OBJECTIVES AND METHODS: This study investigated the sealing ability of a current available unfilled fissure sealant applied over sound (n=80), artificially created (n=80) and naturally carious fissures (n=80) under different humidity conditions (90+/-2 and 45+/-2% relative humidity) and etching times (40 and 60s). All samples were submitted to 5000 thermal cycles and examined by light microscopy after sectioning. Microleakage, penetration ability, fissure type, fissure entrance angle, sealant occlusal length, caries location and caries depth were assessed. RESULTS: The significantly longer sealant occlusal length and larger entrance angle exhibited by shallow fissures, contributed to their higher microleakage and smaller amounts of unfilled areas compared to deep fissures. Sealant microleakage was significantly influenced by the condition of the enamel (sound, artificial and natural caries) and the caries location in the fissures, but not by enamel caries depth (D1 and D2), etching time, or humidity condition. Natural caries exhibited significantly higher microleakage than sound or artificially created carious fissures. CONCLUSIONS: Based on the results of this study, it can be concluded that location of caries in the fissure rather than its depth should be taken into account when applying a fissure sealant. When the borders of the fissure sealant are on carious enamel, a significantly higher microleakage must be expected. The artificial caries model was not a suitable method to assess the behavior of natural fissure caries.
Resumo:
The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device.
Resumo:
OBJECTIVE: To evaluate safety of same-day administration of verteporfin and ranibizumab. METHODS: Prospective, open-label, multicentre study; patients with predominantly classic (n = 13) or occult (n = 19) choroidal neovascularisation secondary to age-related macular degeneration received standard-fluence verteporfin at baseline and months 3, 6 and 9, based on fluorescein angiography (FA). Ranibizumab 0.5 mg was administered at baseline and months 1, 2 and 3. MAIN OUTCOME MEASURE: The incidence of severe vision loss (best-corrected visual acuity (BCVA) loss > or = 30 letters; primary safety assessment). RESULTS: No severe vision loss due to ocular inflammation or uveitis occurred. One patient had moderate vision loss (BCVA loss > or = 15 letters). Three patients had mild/moderate uveitis. Two serious ocular adverse events occurred (retinal pigment epithelial tear and moderate BCVA decrease). No systemic adverse events occurred. At 9 months, all lesions were inactive with no recurrent leakage on FA and optical coherence tomography; macular oedema and subretinal fluid resolved. The mean BCVA measured at 2 m improved by 6.9 letters at 4 months and 2.4 letters at 9 months. CONCLUSIONS/APPLICATION TO CLINICAL PRACTICE: Same-day verteporfin and ranibizumab was safe and not associated with severe vision loss or severe ocular inflammation. Lesions stabilized, with minimal treatment required after month 3.
Resumo:
To demonstrate not only prevention of vision loss but also improvement in best-corrected visual acuity (BCVA) after treatment with ranibizumab on a variable-dosing regimen over 24 months in patients with age-related macular degeneration (AMD).
Resumo:
BACKGROUND: Exudative age-related macular degeneration (AMD) is a sight-threatening event in many elderly people. Some patients have a much better outcome in visual acuity (VA) than others after treatment with photodynamic therapy (PDT) with verteporfin. The combination of fluorescein angiography (FA) and indocyanine green (ICG) angiography using the Heidelberg Retina Angiograph II (HRA 2) should make a delineation of distinct pattern(s) possible in order to better select and assess therapy. METHODS: This is a retrospective, case-control, single-centre study. We identified a total of 168 eyes of 168 patients from July 2003 to June 2006, including 30 eyes of 30 patients with better visual outcome, defined in this study as VA < or = 0.48 logMAR (> or =20/60 Snellen chart) at the end of the study. Best-corrected VA, maximal central retinal thickness as measured by optical coherence tomography, and results of the FA/ICG angiography using the HRA 2 were analyzed. In this article, we discuss patients with polypoidal choroidal vasculopathy (PCV) and their characteristics. RESULTS: The average follow-up time was 15.3 months (range 4-28 months). Seventeen (57%) of the 30 patients with better visual outcome had PCV. All patients in the group with better visual outcome needed fewer PDT treatments compared with our control group of patients with an exudative AMD. INTERPRETATION: Simultaneous FA/ICG angiography using the HRA 2 allowed delineation of a subgroup of patients with PCV who showed a better visual outcome compared with those with other types of exudative AMD, after treatment with PDT.
Resumo:
To evaluate whether complement Factor P (properdin) was present in surgically removed choroidal neovascular membranes of patients with age-related macular degeneration (AMD) and to investigate whether associated pre- and postoperative clinical characteristics can be correlated.
Resumo:
OBJECTIVE To search the literature and assess the short- and long-term release of bisphenol-A (BPA) in human tissues after treatment with dental sealants. DATA Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion with an arbiter. SOURCES Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and Pubmed), EMBASE (via ovid), Cochrane Trials Register and CENTRAL. The reference lists of all eligible studies were hand-searched. STUDY SELECTION In the absence of RCTs, six interventional and two observational studies, examining in vivo BPA release in human salivary, blood and urinary samples, were included. Due to the heterogeneity in methodology and reporting, the main synthesis of the results was qualitative. The quantitative synthesis based on the weighted Z-test could only include two studies. BPA levels identified in saliva ranged from traces below the method's detection limit to 30 μg/ml. In urine, BPA quantities spanned from 0.17 mg/g to 45.4 mg/g. BPA was not traced in any blood sample at any point of time in the relevant studies. The quantitative analysis showed evidence of BPA release one hour after sealant placement compared to the amount traced before restoration (Stouffer's z trend: <0.001). CONCLUSIONS The available evidence on this topic derived from studies that represent a moderate level of evidence. Nevertheless, the available evidence supports that BPA is released in saliva after sealant placement. CLINICAL SIGNIFICANCE From the qualititative and quantitative synthesis of studies, it is reasonable to conclude that BPA is released after placement of some dental pit and fissure sealants in the oral cavity. The biggest quantities are detected in saliva immediately after or one hour after their placement.