29 resultados para CAVITY AND REPLICA METHOD

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tumours in the oral cavity and oropharynx differ in presentation and prognosis and the detection of spread of tumour from one subsite to another is essential for the T-staging. This article reviews the anatomy and describes the pattern of spread of different cancers arising in the oral cavity and oropharynx; the imaging findings on computerized tomography and magnetic resonance imaging are also described. Brief mention is made on the role of newer imaging modalities such as [(18)F]fluorodeoxyglucose-positron emission tomography/computed tomography, perfusion studies and diffusion-weighted magnetic resonance imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new simple method for two-dimensional determination of optical density of macular pigment xanthophyll (ODx) in clinical routine is based on a single blue-reflection fundus image. Individual different vignetting is corrected by a shading function. For its construction, nodes are automatically found in structureless image regions. The influence of stray light in elderly crystalline lenses is compensated by a correction function that depends on age. The reproducibility of parameters in a one-wavelength reflection method determined for three subjects (47, 61, and 78 years old) was: maxODx = 6.3%, meanODx = 4.6%, volume = 6%, and area = 6% already before stray-light correction. ODx was comparable in pseudophakic and in an eye with a crystalline lens of the same 11 subjects after stray-light correction. Significant correlation in ODx was found between the one-wavelength reflection method and the two-wavelength autofluorescence method for pseudophakic and cataract eyes of 19 patients suffering from dry age-related macular degeneration (AMD) (R(2) = 0.855). In pseudophakic eyes, maxODx was significantly lower for dry AMD (n = 45) (ODx = 0.491±0.102 ODU) than in eyes with healthy fundus (n = 22) (ODx = 0.615±0.103 ODU) (p = 0.000033). Also in eyes with crystalline lens, maxODx was lower in AMD (n = 125) (ODx = 0.610±0.093 ODU) than in healthy subjects (n = 45) (ODx = 0.674±0.098 ODU) (p = 0.00019). No dependence on age was found in the pseudophakic eyes both of healthy subjects and AMD patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Taking intraoperative frozen sections (FS) is a widely used procedure in oncologic surgery. However so far no evidence of an association of FS analysis and premalignant changes in the surgical margin exists. Therefore, the aim of this study was to evaluate the impact of FS on different categories of the final margins of squamous cell carcinoma (SCC) of the oral cavity and lips.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the reliability of radiologic identification using visual comparison of ante and post mortem paranasal sinus computed tomography (CT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study a real-world scheduling problem arising in the context of a rolling ingots production. First we review the production process and discuss peculiarities that have to be observed when scheduling a given set of production orders on the production facilities. We then show how to model this scheduling problem using prescribed time lags between operations, different kinds of resources, and sequence-dependent changeovers. A branch-and-bound solution procedure is presented in the second part. The basic principle is to relax the resource constraints by assuming infinite resource availability. Resulting resource conflicts are then stepwise resolved by introducing precedence relationships among operations competing for the same resources. The algorithm has been implemented as a beam search heuristic enumerating alternative sets of precedence relationships.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The clinical tests currently used to assess spinal biomechanics preoperatively are unable to assess true mechanical spinal stiffness. They rely on spinal displacement without considering the force required to deform a patient's spine. We propose a preoperative method for noninvasively quantifying the three-dimensional patient-specific stiffness of the spines of adolescent idiopathic scoliosis patients. METHODS The technique combines a novel clinical test with numerical optimization of a finite element model of the patient's spine. RESULTS A pilot study conducted on five patients showed that the model was able to provide accurate 3D reconstruction of the spine's midline and predict the spine's stiffness for each patient in flexion, bending, and rotation. Statistically significant variation of spinal stiffness was observed between the patients. CONCLUSION This result confirms that spinal biomechanics is patient-specific, which should be taken into consideration to individualize surgical treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present an image quality assessment and enhancement method for high-resolution Fourier-Domain OCT imaging like in sub-threshold retina therapy. A Maximum-Likelihood deconvolution algorithm as well as a histogram-based quality assessment method are evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to describe the tenovaginoscopic approach to the bovine common digital flexor tendon sheath (CDFTS). A comparative anatomical, ultrasonographic and endoscopic study was undertaken using 26 healthy cadaver feet from adult dairy cows. Tenovaginoscopy was performed using a rigid, 30 degrees arthroscope (length 18 cm; outer diameter 4mm) enabling a direct view of the synovial cavity and the following structures: digital flexor tendons, digital annular ligaments, lateral and medial pouches, three mesotendons, the vinculum of the superficial digital flexor tendon, and a slot-shaped opening in the manicaflexoria of the hind feet. Additionally, four clinical cases of septic tenosynovitis treated with lavage under tenovaginoscopic control were examined. Tenovaginoscopy represents a feasible, minimally invasive method for the diagnosis and treatment of septic tenosynovitis of the CDFTS, which allows the degree of alterations of the normal structures to be evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Supraomohyoid neck dissection (SOHND) is currently performed in patients with carcinoma of the oral cavity with clinically negative neck. Most investigators consider SOHND as a staging procedure. METHODS: Records of 100 patients with cancer of the oral cavity and clinically negative neck undergoing SOHND were reviewed. The rate and significance of occult metastases are evaluated, the neck recurrences are analyzed and the indication of adjuvant radiation of pN+ necks is discussed. RESULTS: In 34 of 1814 of analyzed lymph nodes, metastatic disease was detected as follows: 30 macrometastases and 4 micrometastases. In 13 of 34 metastases (38%), extracapsular spread was observed. Twenty of 100 patients (20%) had to be upstaged. In 9 of 87 (10%) patients without local recurrence and with a minimal follow-up of 24 months, 5 ipsilateral (4 within the dissection field) and 5 contralateral neck recurrences were observed. Regional recurrence developed in 4% and 35% of patients with pN0 and pN+ necks, respectively. CONCLUSIONS: In 20% of patients with oral cavity tumors and pN0 neck, occult metastases were disclosed. Neck recurrences developed significantly more often in patients with pN+ than in those with pN0 necks. To evaluate the exact indication for an adjuvant treatment of patients with cN0/pN+ necks, prospective studies should be performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right-left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland-Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast and automatic method for radiocarbon analysis of aerosol samples is presented. This type of analysis requires high number of sample measurements of low carbon masses, but accepts precisions lower than for carbon dating analysis. The method is based on online Trapping CO2 and coupling an elemental analyzer with a MICADAS AMS by means of a gas interface. It gives similar results to a previously validated reference method for the same set of samples. This method is fast and automatic and typically provides uncertainties of 1.5–5% for representative aerosol samples. It proves to be robust and reliable and allows for overnight and unattended measurements. A constant and cross contamination correction is included, which indicates a constant contamination of 1.4 ± 0.2 μg C with 70 ± 7 pMC and a cross contamination of (0.2 ± 0.1)% from the previous sample. A Real-time online coupling version of the method was also investigated. It shows promising results for standard materials with slightly higher uncertainties than the Trapping online approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. OBJECTIVE To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. METHOD A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. RESULTS We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. CONCLUSIONS This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To describe a method of carrying out apical surgery of a maxillary molar using ultrasonics to create a lateral sinus window into the maxillary sinus and an endoscope to enhance visibility during surgery. SUMMARY: A 37-year-old female patient presented with tenderness to percussion of the maxillary second right molar. Root canal treatment had been undertaken, and the tooth restored with a metal-ceramic crown. Radiological examination revealed an apical radiolucency in close proximity to the maxillary sinus. Apical surgery of the molar was performed through the maxillary sinus, using ultrasonics for the osteotomy, creating a window in the lateral wall of the maxillary sinus. During surgery, the lining of the sinus was exposed and elevated without perforation. The root-end was resected using a round tungsten carbide drill, and the root-end cavity was prepared with ultrasonic retrotips. Root-end filling was accomplished with MTA(®) . An endoscope was used to examine the cut root face, the prepared cavity and the root-end filling. No intraoperative or postoperative complications were observed. At the 12-month follow-up, the tooth had no clinical signs or symptoms, and the radiograph demonstrated progressing resolution of the radiolucency. KEY LEARNING POINTS: When conventional root canal retreatment cannot be performed or has failed, apical surgery may be considered, even in maxillary molars with roots in close proximity to the maxillary sinus. Ultrasonic sinus window preparation allows more control and can minimize perforation of the sinus membrane when compared with conventional rotary drilling techniques. The endoscope enhances visibility during endodontic surgery, thus improving the quality of the case.