7 resultados para Breast volume
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Although surgical techniques and the quality of mammary prostheses have been improved significantly in recent years, capsular contracture attendant on prosthetic mammary reconstruction remains a major flaw. Although rarely, some patients are confronted with recurrent and intractable capsular contractures with resultant breast deformity, even after multiple attempts at capsulectomies and implant exchange. Patients with recurrent capsular contracture often do not want replacement with a new prosthesis, but desire the maintenance of their breast volume with a safe alternative. In an attempt to maintain breast volume and to improve the aesthetic appearance, secondary breast reconstruction using bilateral deepithelialized free flaps from the lower abdomen was performed in a series of seven patients. Three bilateral muscle-sparing TRAM flaps, two bilateral DIEP flaps, one bilateral SIEA flap, one unilateral SIEA flap, and one unilateral DIEP flap (a total number of 14 flaps) were used following implant removal, total capsulectomy, and prophylactic subcutaneous mastectomy. The early postoperative course was uneventful, and all flaps survived completely with no complications. There were no donor-site problems, except in one patient (case 5), who had partial skin necrosis of the abdominal flap. The long-term results (mean follow-up: 4.8 years) demonstrated an aesthetically satisfactory appearance of the breasts, with no major donor-site problems. Several advantages, as well as drawbacks, are highlighted with this technique.
Resumo:
As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.
Resumo:
Gynecomastia is the most common breast pathology. Numerous excisions and liposuction techniques have been described to correct bilateral male breast enlargement. Recently, there has been a shift from the open approach to minimally invasive techniques. This article reports a 5-year experience using laser-assisted lipolysis (LAL) to treat gynecomastia, and describes the surgical technique. Between January 2006 and December 2010, a total of 28 patients with bilateral gynecomastia were treated with LAL. Patients had a mean age of 36.5 years (range 24 to 56 years). LAL was performed with a 980-nm diode laser (continuous emission, 15 W power, 8-12 kJ total energy per breast) after tumescent anesthetic infiltration. The breast was evaluated objectively by two physicians who compared chest circumference and photographs. Patients were also asked to score the results using a visual analogue scale: 75 to 100 (very good), 50-74 (good), 25 to 49 (fair) and 0 to 24 (poor). The postoperative period for all patients was incident-free. After 6 months, 18 patients (64.3%) scored the results as "very good", 6 as "good" (21.4%), 3 as "fair" (10.7%) and 1 "poor" (3.6%). Mean chest circumferences pre- and postoperatively were, respectively, 117.4 ± 11.1 cm and 103.3 ± 7.5 cm (p < 0.001), corresponding to a mean difference of 14.1 cm. Physicians scored the photographs as "very good" in 22 patients (78.6%), as "good" in five patients (17.9%), and as "fair" in one patient (3.6%). LAL in gynecomastia is safe and produces significant effects on fatty tissue, with a reduction in breast volume, together with significant skin tightening. Provided an appropriate amount of energy is delivered by an experienced operator, the results are both significant and consistent.
Resumo:
PURPOSE To investigate interobserver variations of target volume delineations in accelerated partial breast irradiation with multicatheter brachytherapy (BT) and to assess the impact of guidelines on consistency of contouring. METHODS AND MATERIALS A contouring study with two phases in interstitial accelerated partial breast irradiation after open cavity surgery was conducted by the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology Breast Cancer Working Group. Contours of cavity and planning target volume (PTV) on preimplant and postimplant CT images were delineated. In Phase 1, nine radiation oncologists defined the target volumes of 5 patients, whereas in Phase 2, four observers draw the contours of 4 patients applying guidelines. In Phase 1, experience in breast BT after open cavity surgery was assessed. The delineations were compared between Phase 1 and Phase 2, the impact of guidelines was assessed, and cavity visualization score was related to consistency of delineations. RESULTS Significant interobserver variability in delineations of lumpectomy cavity and PTV was observed among the participants. Observers with BT experience after open cavity surgery outlined the cavity and PTV more consistently (conformity indexgen: 0.52 vs. 0.48 and 0.59 vs. 0.55 for preimplant and postimplant cavities). For all volumes, the mean Vmax/Vmin was 2.2 vs. 2.8. Having used guidelines all conformity indices increased significantly. For cavity, the increase was 14% and 11%, whereas for the PTV, 28% and 17% on the preimplant and postimplant CT images, respectively. A strong correlation was found between consistency of contours and cavity visualization score. CONCLUSIONS Simple guidelines on defining the lumpectomy cavity significantly increased the consistency of contouring. Reliable consistency of target volume definition can be expected only for good cavity visibility.
Resumo:
The classical DIEP-flap is considered state-of-the-art in microsurgical autologous breast reconstruction. Some patients may require additional volume to match the contralateral breast. This quality control study prospectively evaluates the feasibility and outcome of a surgical technique, which pursues the volumetric augmentation of the DIEP-flap by harvesting of additional subscarpal fat tissue cranial to the classical flap border.
Resumo:
BACKGROUND: Breast reconstruction by latissimus dorsi myocutaneous flap in combination with a prosthesis is a widely used, well-established procedure. Short- and medium-term evaluation after this procedure is well described in the literature, but there have been no evaluations of the late course (over 10 years) published until now. METHODS: In a retrospective study, 68 patients operated on by means of this technique at the authors' institution from 1981 to 1993 resulting in a minimal follow-up of 10 years were included. Patients were invited to an interrogation, clinical examination, and photographic documentation (n = 51). Incidence of late flap or prosthesis-related complications, number of and indications for corrective procedures, and the correlation of the patients' subjective judgment and objective results in the late course have been the main interest of the authors' survey. RESULTS: The authors found that 50 percent of the patients needed a late reoperation for change or removal of the prosthesis. Seven (10 percent) of 68 patients needed a definitive removal of the implant in the late course. Assessment of the photographic documentation of the late result by four nonprofessionals showed that the objective aesthetic results of a considerable number of the authors' reconstructions were not sufficient. CONCLUSION: The procedure combines two basic techniques of reconstructive surgery, the soft-tissue restoration by a pedicled flap as the autologous reconstructive component and the volume reconstruction by prosthesis. Therefore, these patients are subject to a cumulation of the basic morbidity of the two techniques. The authors conclude that the indication for this procedure should be restricted to patients not qualifying for "pure" reconstructive techniques.
Resumo:
In a mouse tumour model for hereditary breast cancer, we previously explored the anti-cancer effects of docetaxel, ritonavir and the combination of both and studied the effect of ritonavir on the intratumoural concentration of docetaxel. The objective of the current study was to apply pharmacokinetic (PK)-pharmacodynamic (PD) modelling on this previous study to further elucidate and quantify the effects of docetaxel when co-administered with ritonavir. PK models of docetaxel and ritonavir in plasma and in tumour were developed. The effect of ritonavir on docetaxel concentration in the systemic circulation of Cyp3a knock-out mice and in the implanted tumour (with inherent Cyp3a expression) was studied, respectively. Subsequently, we designed a tumour growth inhibition model that included the inhibitory effects of both docetaxel and ritonavir. Ritonavir decreased docetaxel systemic clearance with 8% (relative standard error 0.4%) in the co-treated group compared to that in the docetaxel only-treated group. The docetaxel concentration in tumour tissues was significantly increased by ritonavir with mean area under the concentration-time curve 2.5-fold higher when combined with ritonavir. Observed tumour volume profiles in mice could be properly described by the PK/PD model. In the co-treated group, the enhanced anti-tumour effect was mainly due to increased docetaxel tumour concentration; however, we demonstrated a small but significant anti-tumour effect of ritonavir addition (p value <0.001). In conclusion, we showed that the increased anti-tumour effect observed when docetaxel is combined with ritonavir is mainly caused by enhanced docetaxel tumour concentration and to a minor extent by a direct anti-tumour effect of ritonavir.