8 resultados para Blood--Examination

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE Restless legs syndrome (RLS) is a common neurologic disorder. Secondary RLS includes pregnancy and iron deficiency. Prevalence of RLS in pregnancy ranges from 11% to 27%. We aimed to assess the frequency and characteristics of RLS in pregnancy in a Peruvian population and to evaluate the possible pregnancy or delivery complications due to RLS. METHODS We assessed 218 consecutive expectant mothers at the inpatient clinic of the Hospital San Bartolome in Lima, Peru. Assessment was performed by using the standard diagnostic criteria for RLS and by using a clinical and diagnostic interview. Questionnaires for RLS severity, idiopathic RLS (IRLS), and excessive daytime sleepiness (EDS) according to the Epworth sleepiness scale (ESS) were used. Blood examination was performed for hemoglobin and hematocrit. For comparison, RLS patients were matched for age and body mass index (BMI) with pregnant women without RLS. RESULTS Out of 218 patients, 40 (18.4%) fulfilled diagnostic criteria for RLS. In RLS patients, prophylactic iron supplementation therapy during pregnancy was less frequently taken (P=.02). Pregnant women with RLS had a higher ESS score than pregnant controls (10.6 +/- 3.1 vs 7.6. +/- 3.6; P<.001). Preeclampsia was more frequent in RLS (7/40 vs 1/39; P=.03). CONCLUSIONS In our study, RLS was frequent in pregnant Peruvian women, especially in those without prophylactic iron supplementation. RLS patients described more EDS. Preeclampsia was more common in RLS. Our study is the first study to indicate a possible association between RLS and preeclampsia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blood aspiration is a significant forensic finding. In this study, we examined the value of postmortem computed tomography (CT) imaging in evaluating findings of blood aspiration. We selected 37 cases with autopsy evidence of blood in the lungs and/or in the airways previously submitted to total-body CT scanning. The CT-images were retrospectively analyzed. In one case with pulmonary blood aspiration, biopsy specimens were obtained under CT guide for histological examination. In six cases, CT detected pulmonary abnormalities suggestive of blood aspiration, not mentioned in the autopsy reports. CT reconstructions provided additional data about the distribution and extent of aspiration. In one needle-biopsied case, the pulmonary specimens showed blood in the alveoli. We suggest the use of CT imaging as a tool complementary to traditional techniques in cases of blood aspiration to avoid misdiagnosis, to guide the investigation of lung tissue, and to allow for more evidence-based inferences on the cause of death.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the increased use of intracranial neuromonitoring during experimental subarachnoid hemorrhage (SAH), coordinates for probe placement in rabbits are lacking. This study evaluates the safety and reliability of using outer skull landmarks to identify locations for placement of cerebral blood flow (CBF) and intraparenchymal intracranial pressure (ICP) probes. Experimental SAH was performed in 17 rabbits using an extracranial-intracranial shunt model. ICP probes were placed in the frontal lobe and compared to measurements recorded from the olfactory bulb. CBF probes were placed in various locations in the frontal cortex anterior to the coronary suture. Insertion depth, relation to the ventricular system, and ideal placement location were determined by post-mortem examination. ICP recordings at the time of SAH from the frontal lobe did not differ significantly from those obtained from the right olfactory bulb. Ideal coordinates for intraparenchymal CBF probes in the left and right frontal lobe were found to be located 4.6±0.9 and 4.5±1.2 anterior to the bregma, 4.7±0.7mm and 4.7±0.5mm parasagittal, and at depths of 4±0.5mm and 3.9±0.5mm, respectively. The results demonstrate that the presented coordinates based on skull landmarks allow reliable placement of intraparenchymal ICP and CBF probes in rabbit brains without the use of a stereotactic frame.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The examination of urine in children can be very complex, due to the difficulty to obtain clean urine specimens in infants and toddlers. Clean catch is an easy system to obtain urine but patience is needed. Transurethral catheterization or suprapubic aspiration is useful in infants and toddlers with sign of pyelonephritis. Urine bag specimens are not useful in the diagnosis of urinary tract infection because of the high rate of false positive cultures. The 24 hours urine collection is frequently replaced by a spot urine and the ratio of the measured substances with the urine creatinine are calculated. Urine microscopy is needed for the evaluation of pathological results in the dipstick testing: confirm that red urine is due to haematuria by demonstration of red blood cells on urine microscopy, dysmorphic cells and red-cell casts are pathognomonic of glomerular bleeding, white-cell casts signify glomerular inflammation and bacteria are easily seen in unstained urine. A urine culture is pathologic if the colony count exceeds 10(4) in the transurethral catheterization or clean void. In the suprapubic aspiration is any number of colony pathologic. Urate crystals in the urine of infants may cause a pink discoloration to nappies. Urine screenings are not very useful and should be performed only at the age of 5 years or by sexual-active adolescents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

By using an infant rat model of pneumococcal meningitis, we determined whether endothelins contribute to neuronal damage in this disease. Cerebrospinal fluid analysis demonstrated a significant increase of endothelin-1 in infected animals compared with uninfected controls. Histopathological examination 24 hours after infection showed brain damage in animals treated with ceftriaxone alone (median, 9.2% of cortex; range, 0-49.1%). In infected animals treated intraperitoneally with the endothelin antagonist bosentan (30 mg/kg, every 12 hours) also, injury was reduced to 0.5% (range, 0-8.6%) of cortex. Cerebral blood flow was reduced in infected animals (6.5 +/- 4.0 ml/min/100 g of brain vs 14.9 +/- 9.1 ml/min/100 g in controls. Treatment with bosentan restored cerebral blood flow to levels similar to controls (12.8 +/- 5.3 ml/min/100 g). Improved blood flow was not mediated by nitric oxide production, because bosentan had no effect on cerebrospinal fluid or plasma nitrite/nitrate concentrations at 6, 12, or 18 hours. These data indicate that endothelins contribute to neuronal injury in this model of pneumococcal meningitis by causing cerebral ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective-To evaluate pulsed-wave Doppler spectral parameters as a method for distinguishing between neoplastic and inflammatory peripheral lymphadenopathy in dogs. Sample Population-40 superficial lymph nodes from 33 dogs with peripheral lymphadenopathy. Procedures-3 Doppler spectral tracings were recorded from each node. Spectral Doppler analysis including assessment of the resistive index, peak systolic velocity-to-end diastolic velocity (S:D) ratio, diastolic notch velocity-to-peak systolic velocity (N:S) ratio, and end diastolic velocity-to-diastolic notch velocity ratio was performed for each tracing. Several calculation methods were used to determine the Doppler indices for each lymph node. After the ultrasonographic examination, fine needle aspirates or excisional biopsy specimens of the examined lymph nodes were obtained, and lymphadenopathy was classified as either inflammatory or neoplastic (lymphomatous or metastatic) via cytologic or histologic examination. Results of Doppler analysis were compared with cytologic or histopathologic findings. Results-The Doppler index with the highest diagnostic accuracy was the S:D ratio calculated from the first recorded tracing; a cutoff value of 3.22 yielded sensitivity of 91%, specificity of 100%, and negative predictive value of 89% for detection of neoplasia. Overall diagnostic accuracy was 95%. At a sensitivity of 100%, the most accurate index was the N:S ratio calculated from the first recorded tracing; a cutoff value of 0.45 yielded specificity of 67%, positive predictive value of 81%, and overall diagnostic accuracy of 86.5%. Conclusions and Clinical Relevance-Results suggested that noninvasive Doppler spectral analysis may be useful in the diagnosis of neoplastic versus inflammatory peripheral lymphadenopathy in dogs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To analyze how far an ischemic component might have been involved in optic neuritis. METHODS: Case report: a 32-year-old man with symptoms characteristic for optic neuritis underwent extensive clinical, laboratory/serological and vascular examination for systemic associations and vascular involvement. RESULTS: The patient was found to have a temporary ocular blood flow dysregulation and increased plasma endothelin-1 levels which decreased after the acute phase of the optic nerve. CONCLUSIONS: We conclude that there might be an ischemic component in this patient with optic neuritis and hypothesize that this ischemic component is at least in part due to a temporarily increased endothelin-1 level.