3 resultados para Blood bank
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND With increasing demand for umbilical cord blood units (CBUs) with total nucleated cell (TNC) counts of more than 150 × 10(7) , preshipping assessment is mandatory. Umbilical cord blood processing requires aseptic techniques and laboratories with specific air quality and cleanliness. Our aim was to establish a fast and efficient method for determining TNC counts at the obstetric ward without exposing the CBU to the environment. STUDY DESIGN AND METHODS Data from a total of 151 cord blood donations at a single procurement site were included in this prospective study. We measured TNC counts in cord blood aliquots taken from the umbilical cord (TNCCord ), from placenta (TNCPlac ), and from a tubing segment of the sterile collection system (TNCTS ). TNC counts were compared to reference TNC counts in the CBU which were ascertained at the cord blood bank (TNCCBU ). RESULTS TNCTS counts (173 ± 33 × 10(7) cells; calculated for 1 unit) correlated fully with the TNCCBU reference counts (166 ± 33 × 10(7) cells, Pearson's r = 0.97, p < 0.0001). In contrast, TNCCord and TNCPlac counts were more disparate from the reference (r = 0.92 and r = 0.87, respectively). CONCLUSIONS A novel method of measuring TNC counts in tubing segments from the sterile cord blood collection system allows rapid and correct identification of CBUs with high cell numbers at the obstetric ward without exposing cells to the environment. This approach may contribute to cost efficacy as only CBUs with satisfactory TNC counts need to be shipped to the cord blood bank.
Resumo:
There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.
Resumo:
Two competitive concepts of umbilical cord blood (UCB) banking are currently available: either allogeneic UCB is donated to a public bank or autologous cells are stored in a private bank. Allogeneic-autologous hybrid banking is a new concept that combines these two approaches. However, acceptance of hybrid UCB banking among potential donors is unknown to date.