69 resultados para Blood Alcohol Test Equipment.

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phosphatidylethanol (PEth) is considered as specific biomarker of alcohol consumption. Due to accumulation after repeated drinking, PEth is suitable to monitor long-term drinking behavior. To examine the applicability of PEth in "driving under the influence of alcohol" cases, 142 blood samples with blood alcohol concentrations (BAC) ranging from 0.0-3.12 ‰ were analyzed for the presence of PEth homologues 16:0/18:1 (889 ± 878 ng/mL; range alcohol consumption with acceptable sensitivity and specificity in accordance with the 1.6 ‰ BAC limit. With a threshold of 700 ng/mL for PEth 16:0/18:1, prolonged excessive alcohol consumption was detected in 65.9 % of drunk drivers with a BAC ≥ 1.6 ‰ and in 31.6 % of the samples with a BAC < 1.6 ‰. Similar results were obtained for PEth 16:0/18:2 with a threshold of 300 ng/mL. Both criteria, PEth 16:0/18:1 and PEth 16:0/18:2, were conform in the evaluation of drinking habits in 88.7 % of blood samples. These results show the possibility to detect prolonged excessive alcohol consumption, even if the BAC is below the legal threshold of 1.6 ‰ for driving aptitude assessment. As a consequence, concentrations of PEth 16:0/18:1 ≥ 700 ng/mL and of PEth 16:0/18:2 ≥ 300 ng/mL may be considered as indicators for the necessity of driving aptitude assessment in addition to BAC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: For almost 30 years, phosphatidylethanol (PEth) has been known as a direct marker of alcohol consumption. This marker stands for consumption in high amounts and for a longer time period, but it has been also detected after 1 high single intake of ethanol (EtOH). The aim of this study was to obtain further information about the formation and elimination of PEth 16:0/18:1 by simulating extensive drinking. METHODS: After 3 weeks of alcohol abstinence, 11 test persons drank an amount of EtOH leading to an estimated blood ethanol concentration of 1 g/kg on each of 5 successive days. After the drinking episode, they stayed abstinent for 16 days with regular blood sampling. PEth 16:0/18:1 analysis was performed using liquid chromatography-tandem mass spectrometry (high-performance liquid chromatography 1100 system and QTrap 2000 triple quadrupole linear ion trap mass spectrometer. Values of blood alcohol were obtained using a standardized method with headspace gas chromatography flame ionization detector. RESULTS: Maximum measured concentrations of EtOH were 0.99 to 1.83 g/kg (mean 1.32 g/kg). These values were reached 1 to 3 hours after the start of drinking (mean 1.9 hours). For comparison, 10 of 11 volunteers had detectable PEth 16:0/18:1 values 1 hour after the start of drinking, ranging from 45 to 138 ng/ml PEth 16:0/18:1. Over the following days, concentrations of PEth 16:0/18:1 increased continuously and reached the maximum concentrations of 74 to 237 ng/ml between days 3 and 6. CONCLUSIONS: This drinking experiment led to measurable PEth concentrations. However, PEth 16:0/18:1 concentrations stayed rather low compared with those of alcohol abusers from previous studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The forensic utility of fatty acid ethyl esters (FAEEs) in dried blood spots (DBS) as short-term confirmatory markers for ethanol intake was examined. An LC-MS/MS method for the determination of FAEEs in DBS was developed and validated to investigate FAEE formation and elimination in a drinking study, whereby eight subjects ingested 0.66-0.84 g/kg alcohol to reach blood alcohol concentrations (BAC) of 0.8 g/kg. Blood was taken every 1.5-2 h, BAC was determined, and dried blood spots were prepared, with 50 μL of blood, for the determination of FAEEs. Lower limits of quantitation (LLOQ) were between 15 and 37 ng/mL for the four major FAEEs. Validation data are presented in detail. In the drinking study, ethyl palmitate and ethyl oleate proved to be the two most suitable markers for FAEE determination. Maximum FAEE concentrations were reached in samples taken 2 or 4 h after the start of drinking. The following mean peak concentrations (c̅ max) were reached: ethyl myristate 14 ± 4 ng/mL, ethyl palmitate 144 ± 35 ng/mL, ethyl oleate 125 ± 55 ng/mL, ethyl stearate 71 ± 21 ng/mL, total FAEEs 344 ± 91 ng/mL. Detectability of FAEEs was found to be on the same time scale as BAC. In liquid blood samples containing ethanol, FAEE concentrations increase post-sampling. This study shows that the use of DBS fixation prevents additional FAEE formation in blood samples containing ethanol. Positive FAEE results obtained by DBS analysis can be used as evidence for the presence of ethanol in the original blood sample. Graphical Abstract Time courses for fatty acid ethyl ester (FAEE) concentrations in DBS and ethanol concentrations for subject 1 over a period of 7 h. Ethanol ingestion occured during the first hour of the time course.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Urinary tract infections (UTI) are frequent in outpatients. Fast pathogen identification is mandatory for shortening the time of discomfort and preventing serious complications. Urine culture needs up to 48 hours until pathogen identification. Consequently, the initial antibiotic regimen is empirical. Aim To evaluate the feasibility of qualitative urine pathogen identification by a commercially available real-time PCR blood pathogen test (SeptiFast®) and to compare the results with dipslide and microbiological culture. Design of study Pilot study with prospectively collected urine samples. Setting University hospital. Methods 82 prospectively collected urine samples from 81 patients with suspected UTI were included. Dipslide urine culture was followed by microbiological pathogen identification in dipslide positive samples. In parallel, qualitative DNA based pathogen identification (SeptiFast®) was performed in all samples. Results 61 samples were SeptiFast® positive, whereas 67 samples were dipslide culture positive. The inter-methodological concordance of positive and negative findings in the gram+, gram- and fungi sector was 371/410 (90%), 477/492 (97%) and 238/246 (97%), respectively. Sensitivity and specificity of the SeptiFast® test for the detection of an infection was 0.82 and 0.60, respectively. SeptiFast® pathogen identifications were available at least 43 hours prior to culture results. Conclusion The SeptiFast® platform identified bacterial DNA in urine specimens considerably faster compared to conventional culture. For UTI diagnosis sensitivity and specificity is limited by its present qualitative setup which does not allow pathogen quantification. Future quantitative assays may hold promise for PCR based UTI pathogen identification as a supplementation of conventional culture methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Malabsorptive bariatric surgery requires lifelongmicronutrientsupplementation.Basedontherecommendations, we assessed the number of adjustments of micronutrientsupplementationandtheprevalenceofvitaminandmineral deficiencies at a minimum follow-up of 5 years after biliopancreatic diversion with duodenal switch (BPD-DS). Methods Between October 2010 and December 2013, a total of 51 patients at a minimum follow-up of 5 years after BPDDS were invited for a clinical check-up with a nutritional blood screening test for vitamins and minerals. Results Forty-three of fifty-one patients (84.3 %) completed the blood sampling with a median follow-up of 71.2 (range 60–102) monthsafter BPD-DS. At that time,all patientswere supplemented with at least one multivitamin. However, 35 patients (81.4 %) showed either a vitamin or a mineral deficiencyoracombinationofit.Nineteenpatients(44.1%)were anemic,and17patients(39.5%)hadanirondeficiency.High deficiency rates for fat-soluble vitamins were also present in 23.2 % for vitamin A, in 76.7 % for vitamin D, in 7.0 % for vitamin E, and in 11.6 % for vitamin K. Conclusions Theresultsofourstudyshowthattheprevalence ofvitaminandmineraldeficienciesafterBPD-DSis81.4%at a minimum follow-up of 5 years. The initial prescription of micronutrientsupplementationandfurtheradjustmentsduring thefirstfollow-upwereinsufficient toavoidlong-term micronutrient deficiencies. Life-long monitoring of micronutrients at a specialized bariatric center and possibly a better micronutrient supplementation, is crucial to avoid a deficient micronutrient status at every stage after malabsorptive bariatric surgery

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acute vascular rejection (AVR), in particular microvascular thrombosis, is an important barrier to successful pig-to-primate xenotransplantation. Here, we report the generation of pigs with decreased tissue factor (TF) levels induced by small interfering (si)RNA-mediated gene silencing. Porcine fibroblasts were transfected with TF-targeting small hairpin (sh)RNA and used for somatic cell nuclear transfer. Offspring were analyzed for siRNA, TF mRNA and TF protein level. Functionality of TF downregulation was investigated by a whole blood clotting test and a flow chamber assay. TF siRNA was expressed in all twelve liveborn piglets. TF mRNA expression was reduced by 94.1 ± 4.7% in TF knockdown (TFkd) fibroblasts compared to wild-type (WT). TF protein expression in PAEC stimulated with 50 ng/mL TNF-α was significantly lower in TFkd pigs (mean fluorescence intensity TFkd: 7136 ± 136 vs. WT: 13 038 ± 1672). TF downregulation significantly increased clotting time (TFkd: 73.3 ± 8.8 min, WT: 45.8 ± 7.7 min, p < 0.0001) and significantly decreased thrombus formation compared to WT (mean thrombus coverage per viewing field in %; WT: 23.5 ± 13.0, TFkd: 2.6 ± 3.7, p < 0.0001). Our data show that a functional knockdown of TF is compatible with normal development and survival of pigs. TF knockdown could be a valuable component in the generation of multi-transgenic pigs for xenotransplantation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background:  Alcohol is heavily consumed in sub-Saharan Africa and affects HIV transmission and treatment and is difficult to measure. Our goal was to examine the test characteristics of a direct metabolite of alcohol consumption, phosphatidylethanol (PEth). Methods:  Persons infected with HIV were recruited from a large HIV clinic in southwestern Uganda. We conducted surveys and breath alcohol concentration (BRAC) testing at 21 daily home or drinking establishment visits, and blood was collected on day 21 (n = 77). PEth in whole blood was compared with prior 7-, 14-, and 21-day alcohol consumption. Results:  (i) The receiver operator characteristic area under the curve (ROC-AUC) was highest for PEth versus any consumption over the prior 21 days (0.92; 95% confidence interval [CI]: 0.86 to 0.97). The sensitivity for any detectable PEth was 88.0% (95% CI: 76.0 to 95.6) and the specificity was 88.5% (95% CI: 69.8 to 97.6). (ii) The ROC-AUC of PEth versus any 21-day alcohol consumption did not vary with age, body mass index, CD4 cell count, hepatitis B virus infection, and antiretroviral therapy status, but was higher for men compared with women (p = 0.03). (iii) PEth measurements were correlated with several measures of alcohol consumption, including number of drinking days in the prior 21 days (Spearman r = 0.74, p < 0.001) and BRAC (r = 0.75, p < 0.001). Conclusions:  The data add support to the body of evidence for PEth as a useful marker of alcohol consumption with high ROC-AUC, sensitivity, and specificity. Future studies should further address the period and level of alcohol consumption for which PEth is detectable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Chronic alcohol consumption is a risk factor for colorectal cancer. Animal experiments as well as genetic linkage studies in Japanese individuals with inactive acetaldehyde dehydrogenase leading to elevated acetaldehyde concentrations following ethanol ingestion support the hypothesis that acetaldehyde may be responsible for this carcinogenic effect of alcohol. In Caucasians, a polymorphism of alcohol dehydrogenase 1C (ADH1C) exists resulting in different acetaldehyde concentrations following ethanol oxidation. METHODS: To evaluate whether the association between alcohol consumption and colorectal tumor development is modified by ADH1C polymorphism, we recruited 173 individuals with colorectal tumors diagnosed by colonoscopy and 788 control individuals without colorectal tumors. Genotyping was performed using genomic DNA extracted from whole blood followed by polymerase chain reaction. RESULTS: Genotype ADH1C*1/1 was more frequent in patients with alcohol-associated colorectal neoplasia compared to patients without cancers in the multivariate model controlling for age, gender, and alcohol intake (odds ratio = 1.674, 95% confidence interval = 1.110-2.524, 2-sided p from Wald test = 0.0139). In addition, the joint test of the genetic effect and interaction between ADH1C genotype and alcohol intake (2-sided p = 0.0007) indicated that the difference in ADH1C*1 polymorphisms between controls and colorectal neoplasia is strongly influenced by the alcohol consumption and that only individuals drinking more than 30 g ethanol per day with the genotype ADH1C*1/1 had an increased risk for colorectal tumors. CONCLUSIONS: These data identify ADH1C homozygosity as a genetic risk marker for colorectal tumors in individuals consuming more than 30 g alcohol per day and emphasize the role of acetaldehyde as a carcinogenic agent in alcohol-related colorectal carcinogenesis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colorectal cancer (CRC) incidence ranks third among all cancers in Switzerland. Screening the general population could decrease CRC incidence and mortality. The aim of this study was to analyze the use of the fecal occult blood test (FOBT) and lower gastrointestinal endoscopy in a representative sample of the Swiss population aged ≥ 50 years. METHODS Data were analyzed from the 2007 Swiss Health Interview Survey and the prevalence estimates and 95 % confidence intervals were calculated based on all instances of lower gastrointestinal endoscopy and FOBT use, as well as on their use for CRC screening. Uni- and multivariate logistic regression analyses were performed to describe the association between screening use and sociodemographic characteristics, indicators of healthcare system use, and lifestyle factors. RESULTS In 2007, approximately 36 % of the surveyed people who were aged ≥ 50 years had previously undergone FOBT and approximately 30 % had previously undergone lower gastrointestinal endoscopy. CRC screening use was 7.7 % for FOBT (within the past year) and 6.4 % for lower gastrointestinal endoscopy (within the past 5 years). CRC screening by either method was 13 %. The major determinants of participation in CRC screening were found to be sex (male), physician visits during the past year (one or more), type of health insurance (private), and previous screening for other cancer types. CONCLUSIONS The results of the 2007 Swiss Health Interview Survey indicate rather low levels of FOBT and lower gastrointestinal endoscopy use. Furthermore, the results suggest disparities in the use of CRC screening.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are non-oxidative minor metabolites of ethanol. They are detectable in various body fluids shortly after initial consumption of ethanol and have a longer detection time frame than the parent compound. They are regarded highly sensitive and specific markers of recent alcohol uptake. This study evaluates the determination of EtG and EtS from dried blood spots (DBS), a simple and cost-effective sampling method that would shorten the time gap between offense and blood sampling and lead to a better reflectance of the actual impairment. METHODS: For method validation, EtG and EtS standard and quality control samples were prepared in fresh human heparinized blood and spotted on DBS cards, then extracted and measured by an LC-ESI-MS/MS method. Additionally, 76 heparinized blood samples from traffic offense cases were analyzed for EtG and EtS as whole blood and as DBS specimens. The results from these measurements were then compared by calculating the respective mean values, by a matched-paired t test, by a Wilcoxon test, and by Bland-Altman and Mountain plots. RESULTS AND DISCUSSION: Calibrations for EtG and EtS in DBS were linear over the studied calibration range. The precision and accuracy of the method met the requirements of the validation guidelines that were employed in the study. The stability of the biomarkers stored as DBS was demonstrated under different storage conditions. The t test showed no significant difference between whole blood and DBS in the determination of EtG and EtS. In addition, the Bland-Altman analysis and Mountain plot confirmed that the concentration differences that were measured in DBS specimens were not relevant.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the last century, several mathematical models have been developed to calculate blood ethanol concentrations (BAC) from the amount of ingested ethanol and vice versa. The most common one in the field of forensic sciences is Widmark's equation. A drinking experiment with 10 voluntary test persons was performed with a target BAC of 1.2 g/kg estimated using Widmark's equation as well as Watson's factor. The ethanol concentrations in the blood were measured using headspace gas chromatography/flame ionization and additionally with an alcohol Dehydrogenase (ADH)-based method. In a healthy 75-year-old man a distinct discrepancy between the intended and the determined blood ethanol concentration was observed. A blood ethanol concentration of 1.83 g/kg was measured and the man showed signs of intoxication. A possible explanation for the discrepancy is a reduction of the total body water content in older people. The incident showed that caution is advised when using the different mathematical models in aged people. When estimating ethanol concentrations, caution is recommended with calculated results due to potential discrepancies between mathematical models and biological systems

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The importance of direct and indirect alcohol markers to evaluate alcohol consumption in clinical and forensic settings is increasingly recognized. While some markers are used to prove abstinence from ethanol, other markers are suitable for detection of alcohol misuse. Phosphatidyl ethanol (PEth) is ranked among the latter. There is only little information about the correlation between PEth and other currently used markers (ethyl glucuronide, ethyl sulfate, carbohydrate deficient transferrin, gamma-glutamyl transpeptidase, and methanol) and about their decline during detoxification. To get more information, 18 alcohol-dependent patients in withdrawal therapy were monitored for These parameters in blood and urine for up to 19 days. There was no correlation between the different markers. PEth showed a rapid decrease at the beginning of the intervention, a slow decline after the first few days, and could still be detected after 19 days of abstinence from ethanol.