92 resultados para Block infraorbital nerve

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate the histomorphological changes of the infraorbital nerve of rats treated with ampicillin.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The anterior superior alveolar nerve (ASAN) is a branch of the infraorbital nerve. Only few studies have morphometrically evaluated the course of the ASAN. Midfacial segments of ten hemisectioned fresh adult cadaver heads were dissected to uncover the anterior wall of the maxilla. Specimens were subsequently decalcified and the bone overlying the ASAN was removed under a microscope to expose the ASAN. Its branching pattern from the infraorbital nerve was recorded, and the course of the ASAN within the anterior wall of the maxillary sinus was morphometrically assessed measuring distances to predefined landmarks using a digital caliper. A distinct ASAN was observed in all specimens. It arose lateral (six cases) or inferior (four cases) from the infraorbital nerve. The point of origin was located at a mean distance of 12.2 ± 5.79 mm posterior to the infraorbital foramen. The ASAN was located on average 2.8 ± 5.13 mm lateral to the infraorbital foramen. After coursing medially, the ASAN ran inferior to the foramen at a mean distance of 5.5 ± 3.07 mm. When approaching the nasal aperture, the loop of the ASAN was on average 13.6 ± 3.07 mm above the nasal floor. The horizontal mean distance from the ASAN to the nasal aperture was 4.3 ± 2.74 mm halfway down from the loop, and 3.3 ± 2.60 mm at the floor of the nose, respectively. In conclusion, the present study evaluated the course of the ASAN relative to the infraorbital foramen and nasal aperture. This information is helpful to avoid damage to this anatomical structure during interventions in the infraobrital region of the maxilla. Further, knowledge of the course of the ASAN and of its bony correlate (canalis sinuosus) may be valuable in interpreting anesthetic or radiologic findings in the anterior maxilla.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ultrasound (US) is an emerging imaging technique in interventional pain management. The main advantages are the identification of soft tissues, vessels, and nerves, without exposing patients and personnel to radiation, the possibility to perform continuous imaging, and the visualization of the fluid injected in a real-time fashion. Possible applications are nerve blocks of the cervical and lumbar zygapophysial joints, stellate ganglion block, intercostal nerve blocks, occipital nerve blocks, blocks of the inguinal nerves, peripheral nerve blocks of the extremities, blocks of painful stump neuromas, caudal epidural injections, and injections of tender points. US may also be used for destructive procedures, such as cryoanalgesia, radiofrequency lesions, or chemical neurolysis. The increasing published data available suggest that US has a potential usefulness in interventional pain management, but also limitations. There is still a need for clinical trials investigating efficacy and safety of US-guided pain procedures. Until these studies are made, fluoroscopy or computed tomography remain the gold standard for most interventional pain procedures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Little is known about the learning of the skills needed to perform ultrasound- or nerve stimulator-guided peripheral nerve blocks. The aim of this study was to compare the learning curves of residents trained in ultrasound guidance versus residents trained in nerve stimulation for axillary brachial plexus block. Ten residents with no previous experience with using ultrasound received ultrasound training and another ten residents with no previous experience with using nerve stimulation received nerve stimulation training. The novices' learning curves were generated by retrospective data analysis out of our electronic anaesthesia database. Individual success rates were pooled, and the institutional learning curve was calculated using a bootstrapping technique in combination with a Monte Carlo simulation procedure. The skills required to perform successful ultrasound-guided axillary brachial plexus block can be learnt faster and lead to a higher final success rate compared to nerve stimulator-guided axillary brachial plexus block.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to describe the sciatic-femoral nerve block (SFNB) in goats and to evaluate the peri-operative analgesia when the goats underwent stifle arthrotomy. The animals were randomly assigned to one of four treatment groups: groups 0.25, 0.5 and 0.75 received 0.25%, 0.5% and 0.75% of bupivacaine, respectively, while group C (control group) received 0.9% NaCl. In all groups, the volume administered was 0.2 mL/kg. Intra-operatively, the proportion of animals receiving rescue propofol was significantly lower in groups 0.5 and 0.75, compared to group C. Post-operatively, the visual analogue scale (VAS) and total pain score were significantly higher in group C than in the other groups. Group 0.75 had the highest percentage of animals showing motor blockade. SFNB performed with bupivacaine resulted in better intra- and post-operative analgesia than SFNB performed with saline. Compared to the other concentrations, 0.5% bupivacaine resulted in satisfactory analgesia with acceptable side effects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The suprascapular nerve (SSN) block is frequently performed for different shoulder pain conditions and for perioperative and postoperative pain control after shoulder surgery. Blind and image-guided techniques have been described, all of which target the nerve within the supraspinous fossa or at the suprascapular notch. This classic target point is not always ideal when ultrasound (US) is used because it is located deep under the muscles, and hence the nerve is not always visible. Blocking the nerve in the supraclavicular region, where it passes underneath the omohyoid muscle, could be an attractive alternative.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective  To develop an ultrasound-guided technique for retrobulbar nerve block in horses, and to compare the distribution of three different volumes of injected contrast medium (CM) (4, 8 and 12 mL), with the hypothesis that successful placement of the needle within the retractor bulbi muscle cone would lead to the most effective dispersal of CM towards the nerves leaving the orbital fissure. Study design  Prospective experimental cadaver study. Animals  Twenty equine cadavers. Methods  Ultrasound-guided retrobulbar injections were performed in 40 cadaver orbits. Ultrasound visualization of needle placement within the retractor bulbi muscle cone and spread of injected CM towards the orbital fissure were scored. Needle position and destination of CM were then assessed using computerized tomography (CT), and comparisons performed between ultrasonographic visualization of orbital structures and success rate of injections (intraconal needle placement, CM reaching the orbital fissure). Results  Higher scores for ultrasound visualization resulted in a higher success rate for intraconal CM injection, as documented on the CT images. Successful intraconal placement of the needle (22/34 orbits) resulted in CM always reaching the orbital fissure. CM also reached the orbital fissure in six orbits where needle placement was extraconal. With 4, 8 and 12 mL CM, the orbital fissure was reached in 16/34, 23/34 and 28/34 injections, respectively. Conclusion and clinical relevance  The present study demonstrates the use of ultrasound for visualization of anatomical structures and needle placement during retrobulbar injections in equine orbits. However, this approach needs to be repeated in controlled clinical trials to assess practicability and effectiveness in clinical practice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Evidence-based information is limited on distribution of local anaesthetic solution following perineural analgesia of the palmar (Pa) and palmar metacarpal (PaM) nerves in the distal aspect of the metacarpal (Mc) region ('low 4-point nerve block'). OBJECTIVES: To demonstrate the potential distribution of local anaesthetic solution after a low 4-point nerve block using a radiographic contrast model. METHODS: A radiodense contrast medium was injected subcutaneously over the medial or the lateral Pa nerve at the junction of the proximal three-quarters and distal quarter of the Mc region (Pa injection) and over the ipsilateral PaM nerve immediately distal to the distal aspect of the second or fourth Mc bones (PaM injection) in both forelimbs of 10 mature horses free from lameness. Radiographs were obtained 0, 10 and 20 min after injection and analysed subjectively and objectively. Methylene blue and a radiodense contrast medium were injected in 20 cadaver limbs using the same techniques. Radiographs were obtained and the limbs dissected. RESULTS: After 31/40 (77.5%) Pa injections, the pattern of the contrast medium suggested distribution in the neurovascular bundle. There was significant proximal diffusion with time, but the main contrast medium patch never progressed proximal to the mid-Mc region. The radiological appearance of 2 limbs suggested that contrast medium was present in the digital flexor tendon sheath (DFTS). After PaM injections, the contrast medium was distributed diffusely around the injection site in the majority of the limbs. In cadaver limbs, after Pa injections, the contrast medium and the dye were distributed in the neurovascular bundle in 8/20 (40%) limbs and in the DFTS in 6/20 (30%) of limbs. After PaM injections, the contrast and dye were distributed diffusely around the injection site in 9/20 (45%) limbs and showed diffuse and tubular distribution in 11/20 (55%) limbs. CONCLUSIONS AND POTENTIAL RELEVANCE: Proximal diffusion of local anaesthetic solution after a low 4-point nerve block is unlikely to be responsible for decreasing lameness caused by pain in the proximal Mc region. The DFTS may be penetrated inadvertently when performing a low 4-point nerve block.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Chronic neck pain after whiplash injury is caused by cervical zygapophysial joints in 50% of patients. Diagnostic blocks of nerves supplying the joints are performed using fluoroscopy. The authors' hypothesis was that the third occipital nerve can be visualized and blocked with use of an ultrasound-guided technique. METHODS: In 14 volunteers, the authors placed a needle ultrasound-guided to the third occipital nerve on both sides of the neck. They punctured caudal and perpendicular to the 14-MHz transducer. In 11 volunteers, 0.9 ml of either local anesthetic or normal saline was applied in a randomized, double-blind, crossover manner. Anesthesia was controlled in the corresponding skin area by pinprick and cold testing. The position of the needle was controlled by fluoroscopy. RESULTS: The third occipital nerve could be visualized in all subjects and showed a median diameter of 2.0 mm. Anesthesia was missing after local anesthetic in only one case. There was neither anesthesia nor hyposensitivity after any of the saline injections. The C2-C3 joint, in a transversal plane visualized as a convex density, was identified correctly by ultrasound in 27 of 28 cases, and 23 needles were placed correctly into the target zone. CONCLUSIONS: The third occipital nerve can be visualized and blocked with use of an ultrasound-guided technique. The needles were positioned accurately in 82% of cases as confirmed by fluoroscopy; the nerve was blocked in 90% of cases. Because ultrasound is the only available technique today to visualize this nerve, it seems to be a promising new method for block guidance instead of fluoroscopy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recently, our study group demonstrated the usefulness of ultrasonographic guidance in ilioinguinal/iliohypogastric nerve blocks in children. As a consequence, we designed a follow-up study to evaluate the optimal volume of local anesthetic for this regional anesthetic technique. Using a modified step-up-step-down approach, with 10 children in each study group, a starting dose of 0.2 mL/kg of 0.25% levobupivacaine was administered to perform an ilioinguinal/iliohypogastric nerve block under ultrasonographic guidance. After each group of 10 patients, the results were analyzed, and if all blocks were successful, the volume of local anesthetic was decreased by 50%, and a further 10 patients were enrolled into the study. Failure to achieve a 100% success rate within a group subjected patients to an automatic increase of half the previous volume reduction to be used in the subsequent group. Using 0.2 and 0.1 mL/kg of 0.25% levobupivacaine, the success rate was 100%. With a volume of 0.05 mL/kg of 0.25% levobupivacaine, 4 of 10 children received additional analgesia because of an inadequate block. Therefore, according to the protocol, the amount was increased to 0.075 mL/kg of 0.25% levobupivacaine, where the success rate was again 100%. We conclude that ultrasonographic guidance for ilioinguinal/iliohypogastric nerve blocks in children allowed a reduction of the volume of local anesthetic to 0.075 mL/kg.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Nerve blocks using local anesthetics are widely used. High volumes are usually injected, which may predispose patients to associated adverse events. Introduction of ultrasound guidance facilitates the reduction of volume, but the minimal effective volume is unknown. In this study, we estimated the 50% effective dose (ED50) and 95% effective dose (ED95) volume of 1% mepivacaine relative to the cross-sectional area of the nerve for an adequate sensory block. METHODS: To reduce the number of healthy volunteers, we used a volume reduction protocol using the up-and-down procedure according to the Dixon average method. The ulnar nerve was scanned at the proximal forearm, and the cross-sectional area was measured by ultrasound. In the first volunteer, a volume of 0.4 mL/mm of nerve cross-sectional area was injected under ultrasound guidance in close proximity to and around the nerve using a multiple injection technique. The volume in the next volunteer was reduced by 0.04 mL/mm in case of complete blockade and augmented by the same amount in case of incomplete sensory blockade within 20 mins. After 3 up-and-down cycles, ED50 and ED95 were estimated. Volunteers and physicians performing the block were blinded to the volume used. RESULTS: A total 17 of volunteers were investigated. The ED50 volume was 0.08 mL/mm (SD, 0.01 mL/mm), and the ED95 volume was 0.11 mL/mm (SD, 0.03 mL/mm). The mean cross-sectional area of the nerves was 6.2 mm (1.0 mm). CONCLUSIONS: Based on the ultrasound measured cross-sectional area and using ultrasound guidance, a mean volume of 0.7 mL represents the ED95 dose of 1% mepivacaine to block the ulnar nerve at the proximal forearm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study was to evaluate the clinical usefulness, in terms of analgesic efficacy and safety, of ultrasound-guided pudendal nerve block performed with bupivacaine in cats undergoing perineal urethrostomy. Eighteen client-owned male cats scheduled for perineal urethrostomy were enrolled in the study and assigned to one of two treatment groups. The pudendal nerve block was performed under general anaesthesia as described elsewhere, with 0.3 ml/kg of either saline (group C) or 0.5% bupivacaine (group B) - the total injection volume being split equally on the two sites of injection (left and right). Intra-operatively, assessment of nociception was based on the rescue analgesics requirement, as well as on the evaluation of changes in physiological parameters in comparison with the baseline values. Post-operative pain assessment was performed using three different pain scales at recovery and then 1, 2 and 3 h after recovery. Cats in group B showed lower heart rates and required fewer analgesics during surgery than group C. Post-operatively, group B had lower pain scores and needed less rescue buprenorphine than group C. Iatrogenic block-related complications were not observed. In conclusion, the ultrasound-guided pudendal nerve block can be considered clinically useful in feline medicine as it provides reliable analgesia in cats undergoing perineal urethrostomy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES Sonographic guidance for peripheral nerve anesthesia has proven increasingly successful in clinical practice; however, fears that a change to sonographically guided regional anesthesia may impair the block quality and operating room work flow persist in certain units. In this retrospective cohort study, block quality and patient satisfaction during the transition period from nerve stimulator to sonographic guidance for axillary brachial plexus anesthesia in a tertiary referral center were investigated. METHODS Anesthesia records of all patients who had elective surgery of the wrist or hand during the transition time (September 1, 2006-August 25, 2007) were reviewed for block success, placement time, anesthesiologist training level, local anesthetic volume, and requirement of additional analgesics. Postoperative records were reviewed, and patient satisfaction was assessed by telephone interviews in matched subgroups. RESULTS Of 415 blocks, 341 were sonographically guided, and 74 were nerve stimulator guided. Sonographically guided blocks were mostly performed by novices, whereas nerve stimulator-guided blocks were performed by advanced users (72.3% versus 14%; P < .001). Block performance times and success rates were similar in both groups. In sonographically guided blocks, significantly less local anesthetics were applied compared to nerve stimulator-guided blocks (mean ± SD, 36.1 ± 7.1 versus 43.9 ± 6.1 mL; P< .001), and less opioids were required (fentanyl, 66.1 ± 30 versus 90 ± 62 μg; P< .001). Interviewed patients reported significantly less procedure-related discomfort, pain, and prolonged procedure time when block placement was sonographically guided (2% versus 20%; P = .002). CONCLUSIONS Transition from nerve stimulator to sonographic guidance for axillary brachial plexus blocks did not change block performance times or success rates. Patient satisfaction was improved even during the early institutional transition period.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this prospective experimental cadaveric study was to develop an ultrasound-guided technique to perform an anaesthetic pudendal nerve block in male cats. Fifteen fresh cadavers were used for this trial. A detailed anatomical dissection was performed on one cat in order to scrutinise the pudendal nerve and its ramifications. In a second step, the cadavers of six cats were used to test three different ultrasonographic approaches to the pudendal nerve: the deep dorso-lateral, the superficial dorso-lateral and the median transperineal. Although none of the approaches allowed direct ultrasonographical identification of the pudendal nerve branches, the deep dorso-lateral was found to be the most advantageous one in terms of practicability and ability to identify useful and reliable landmarks. Based on these findings, the deep dorso-lateral approach was selected as technique of choice for tracer injections (0.1 ml 1% methylene blue injected bilaterally) in six cat cadavers distinct from those used for the ultrasonographical study. Anatomical dissection revealed a homogeneous spread of the tracer around the pudendal nerve sensory branches in all six cadavers. Finally, computed tomography was performed in two additional cadavers after injection of 0.3 ml/kg (0.15 ml/kg per each injection sites, left and right) contrast medium through the deep dorso-lateral approach in order to obtain a model of volume distribution applicable to local anaesthetics. Our findings in cat cadavers indicate that ultrasound-guided pudendal nerve block is feasible and could be proposed to provide peri-operative analgesia in clinical patients undergoing perineal urethrostomy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE To describe the nerve stimulator-guided sciatic-femoral nerve block in raptors undergoing surgical treatment of pododermatitis. STUDY DESIGN Prospective clinical trial. ANIMALS Five captive raptors (Falco peregrinus) aged 6.7 ± 1.3 years. METHODS Anaesthesia was induced and maintained with isoflurane in oxygen. The sciatic-femoral nerve block was performed with 2% lidocaine (0.05 mL kg(-1) per nerve) as the sole intra-operative analgesic treatment. Intraoperative physiological variables were recorded every 10 minutes from endotracheal intubation until the end of anaesthesia. Assessment of intraoperative nociception was based on changes in physiological variables above baseline values, while evaluation of postoperative pain relied on species-specific behavioural indicators. RESULTS The sciatic-femoral nerve block was feasible in raptors and the motor responses following electrical stimulation of both nerves were consistent with those reported in mammalian species. During surgery no rescue analgesia was required. The anaesthesia plane was stable and cardiorespiratory variables did not increase significantly in response to surgical stimulation. Iatrogenic complications, namely nerve damage and local anaesthetic toxicity, did not occur. Recovery was smooth and uneventful. The duration (mean ± SD) of the analgesic effect provided by the nerve block was 130 ± 20 minutes. CONCLUSION AND CLINICAL RELEVANCE The sciatic-femoral nerve block as described in dogs and rabbits can be performed in raptors as well. Further clinical trials with a control groups are required to better investigate the analgesic efficacy and the safety of this technique in raptors.