55 resultados para Bitcoin, IoT, Raspberry Pi, Vending machine, Distributore intelligente
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Environmental cues can affect food decisions. There is growing evidence that environmental cues influence how much one consumes. This article demonstrates that environmental cues can similarly impact the healthiness of consumers’ food choices. Two field studies examined this effect with consumers of vending machine foods who were exposed to different posters. In field study 1, consumers with a health-evoking nature poster compared to a pleasure-evoking fun fair poster or no poster in their visual sight were more likely to opt for healthy snacks. Consumers were also more likely to buy healthy snacks when primed by an activity poster than when exposed to the fun fair poster. In field study 2, this consumer pattern recurred with a poster of skinny Giacometti sculptures. Overall, the results extend the mainly laboratory-based evidence by demonstrating the health-relevant impact of environmental cues on food decisions in the field. Results are discussed in light of priming literature emphasizing the relevance of preexisting associations, mental concepts and goals.
Resumo:
The release of phosphate (Pi) is an important element in actomyosin function and has been shown to be accelerated by the binding of myosin to actin. To provide information about the structural elements important for Pi release, possible escape pathways from various isolated myosin II structures have been determined by molecular dynamics simulations designed for studying such slow processes. The residues forming the pathways were identified and their role was evaluated by mutant simulations. Pi release is slow in the pre-powerstroke structure, an important element in preventing the powerstroke prior to actin binding, and is much more rapid for Pi modeled into the post-rigor and rigor-like structures. The previously proposed backdoor route is dominant in the pre-powerstroke and post-rigor states, whereas a different path is most important in the rigor-like state. This finding suggests a mechanism for the actin-activated acceleration of Pi release.
Resumo:
Dual-boosted protease inhibitors (DBPI) are an option for salvage therapy for HIV-1 resistant patients. Patients receiving a DBPI in the Swiss HIV Cohort Study between January1996 and March 2007 were studied. Outcomes of interest were viral suppression at 24 weeks. 295 patients (72.5%) were on DBPI for over 6 months. The median duration was 2.2 years. Of 287 patients who had HIV-RNA >400?copies/ml at the start of the regimen, 184 (64.1%) were ever suppressed while on DBPI and 156 (54.4%) were suppressed within 24 weeks. The median time to suppression was 101 days (95% confidence interval 90-125 days). The median number of past regimens was 6 (IQR, 3-8). The main reasons for discontinuing the regimen were patient's wish (48.3%), treatment failure (22.5%), and toxicity (15.8%). Acquisition of HIV through intravenous drug use and the use of lopinavir in combination with saquinavir or atazanavir were associated with an increased likelihood of suppression within 6 months. Patients on DBPI are heavily treatment experienced. Viral suppression within 6 months was achieved in more than half of the patients. There may be a place for DBPI regimens in settings where more expensive alternates are not available.
Resumo:
Delineating brain tumor boundaries from magnetic resonance images is an essential task for the analysis of brain cancer. We propose a fully automatic method for brain tissue segmentation, which combines Support Vector Machine classification using multispectral intensities and textures with subsequent hierarchical regularization based on Conditional Random Fields. The CRF regularization introduces spatial constraints to the powerful SVM classification, which assumes voxels to be independent from their neighbors. The approach first separates healthy and tumor tissue before both regions are subclassified into cerebrospinal fluid, white matter, gray matter and necrotic, active, edema region respectively in a novel hierarchical way. The hierarchical approach adds robustness and speed by allowing to apply different levels of regularization at different stages. The method is fast and tailored to standard clinical acquisition protocols. It was assessed on 10 multispectral patient datasets with results outperforming previous methods in terms of segmentation detail and computation times.
Resumo:
The N-H center dot center dot center dot pi hydrogen bond is an important intermolecular interaction in many biological systems. We have investigated the infrared (IR) and ultraviolet (UV) spectra of the supersonic-jet cooled complex of pyrrole with benzene and benzene-d(6) (Pyr center dot Bz, Pyr center dot Bz-d(6)). DFT-D density functional, SCS-MP2 and SCS-CC2 calculations predict a T-shaped and (almost) C(s) symmetric structure with an N-H center dot center dot center dot pi hydrogen bond to the benzene ring. The pyrrole is tipped by omega(S(0)) = +/- 13 degrees relative to the surface normal of Bz. The N center dot center dot center dot ring distance is 3.13 angstrom. In the S(1) excited state, SCS-CC2 calculations predict an increased tipping angle omega(S(1)) = +/- 21 degrees. The IR depletion spectra support the T-shaped geometry: The NH stretch is redshifted by -59 cm(-1), relative to the "free" NH stretch of pyrrole at 3531 cm(-1), indicating a moderately strong N-H center dot center dot center dot pi interaction. The interaction is weaker than in the (Pyr)(2) dimer, where the NH donor shift is -87 cm(-1) [Dauster et al., Phys. Chem. Chem. Phys., 2008, 10, 2827]. The IR C-H stretch frequencies and intensities of the Bz subunit are very similar to those of the acceptor in the (Bz)(2) dimer, confirming that Bz acts as the acceptor. While the S(1) <- S(0) electronic origin of Bz is forbidden and is not observable in the gas-phase, the UV spectrum of Pyr center dot Bz in the same region exhibits a weak 0(0)(0) band that is red-shifted by 58 cm(-1) relative to that of Bz (38 086 cm(-1)). The origin appears due to symmetry-breaking of the p-electron system of Bz by the asymmetric pyrrole NH center dot center dot center dot pi hydrogen bond. This contrasts with (Bz)(2), which does not exhibit a 0(0)(0) band. The Bz moiety in Pyr center dot Bz exhibits a 6a(0)(1) band at 0(0)(0) + 518 cm(-1) that is about 20x more intense than the origin band. The symmetry breaking by the NH center dot center dot center dot pi hydrogen bond splits the degeneracy of the v(6)(e(2g)) vibration, giving rise to 6a' and 6b' sub-bands that are spaced by similar to 6 cm(-1). Both the 0(0)(0) and 6(0)(1) bands of Pyr center dot Bz carry a progression in the low-frequency (10 cm(-1)) excited-state tipping vibration omega', in agreement with the change of the omega tipping angle predicted by SCS-MP2 and SCS-CC2 calculations.
Resumo:
The electron Monte Carlo (eMC) dose calculation algorithm available in the Eclipse treatment planning system (Varian Medical Systems) is based on the macro MC method and uses a beam model applicable to Varian linear accelerators. This leads to limitations in accuracy if eMC is applied to non-Varian machines. In this work eMC is generalized to also allow accurate dose calculations for electron beams from Elekta and Siemens accelerators. First, changes made in the previous study to use eMC for low electron beam energies of Varian accelerators are applied. Then, a generalized beam model is developed using a main electron source and a main photon source representing electrons and photons from the scattering foil, respectively, an edge source of electrons, a transmission source of photons and a line source of electrons and photons representing the particles from the scrapers or inserts and head scatter radiation. Regarding the macro MC dose calculation algorithm, the transport code of the secondary particles is improved. The macro MC dose calculations are validated with corresponding dose calculations using EGSnrc in homogeneous and inhomogeneous phantoms. The validation of the generalized eMC is carried out by comparing calculated and measured dose distributions in water for Varian, Elekta and Siemens machines for a variety of beam energies, applicator sizes and SSDs. The comparisons are performed in units of cGy per MU. Overall, a general agreement between calculated and measured dose distributions for all machine types and all combinations of parameters investigated is found to be within 2% or 2 mm. The results of the dose comparisons suggest that the generalized eMC is now suitable to calculate dose distributions for Varian, Elekta and Siemens linear accelerators with sufficient accuracy in the range of the investigated combinations of beam energies, applicator sizes and SSDs.