32 resultados para Bifurcation de boucle hétéroclinique

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite rapid advances in the development of materials and techniques for endovascular intracranial aneurysm treatment, occlusion of large broad-neck aneurysms remains a challenge. Animal models featuring complex aneurysm architecture are needed to test endovascular innovations and train interventionalists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The choice of the experimental aneurysm model is essential for valid embolization-device evaluations. So far, the use of the rabbit venous pouch arterial bifurcation aneurysm model has been limited by demanding microsurgery, low aneurysm patency rates, and high mortality. This study aimed to facilitate microsurgery and to reduce mortality by optimized peri-/postoperative management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In experimental aneurysm models, long-term patency without spontaneous thrombosis is the most important precondition for analyses of embolization devices. We recently reported the feasibility of creating complex venous pouch bifurcation aneurysms in the rabbit with low morbidity, low mortality, and high short-term aneurysm patency. In order to further evaluate our model, we examined the long-term patency rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE We investigated clinical outcomes after treatment of coronary bifurcation lesions with second generation drug eluting stents (DES). DESIGN Post hoc analysis of a randomised, multicentre, non-inferiority trial. SETTING Multicentre study. PATIENTS All comers study with minimal exclusion criteria. INTERVENTIONS Patients were treated with either zotarolimus or everolimus eluting stents. The patient population was divided according to treatment of bifurcation or non-bifurcation lesions and clinical outcomes were compared between groups. MAIN OUTCOMES MEASURES Clinical outcomes within 2-year follow-up. RESULTS A total of 2265 patients were included in the present analysis. Two-year follow-up data were available in 2223 patients: 1838 patients in the non-bifurcation group and 385 patients in the bifurcation group. At 2-year follow-up the bifurcation and the non-bifurcation lesion groups showed no significant differences in terms of cardiac death (2.3 vs 2.1, p=0.273), target lesion failure (9.7% vs 13.8%, p=0.255), major adverse cardiac events (11.5% vs 15.1%, p=0.305), target lesion revascularisation (4.7% vs 6.0%, p=0.569), and definite or probable stent thrombosis (1.6% vs 1.8%, p=0.419). CONCLUSIONS The use of second generation DES for the treatment of coronary bifurcation lesions was associated with similar long term mortality and clinical outcomes compared with non-bifurcation lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS To investigate the outcomes of percutaneous coronary intervention (PCI) in bifurcation versus non-bifurcation lesions using the next-generation Resolute zotarolimus-eluting stent (R-ZES). METHODS AND RESULTS We analyzed 3-year pooled data from the RESOLUTE All-Comers trial and the RESOLUTE International registry. The R-ZES was used in 2772 non-bifurcation lesion patients and 703 bifurcation lesion patients, of which 482 were treated with a simple-stent technique (1 stent used to treat the bifurcation lesion) and 221 with a complex bifurcation technique (2 or more stents used). The primary endpoint was 3-year target lesion failure (TLF, defined as the composite of death from cardiac causes, target vessel myocardial infarction, or clinically-indicated target lesion revascularization [TLR]), and was 13.3% in bifurcation vs 11.3% in non-bifurcation lesion patients (adjusted P=.06). Landmark analysis revealed that this difference was driven by differences in the first 30 days between bifurcation vs non-bifurcation lesions (TLF, 6.6% vs 2.7%, respectively; adjusted P<.001), which included significant differences in each component of TLF and in-stent thrombosis. Between 31 days and 3 years, TLF, its components, and stent thrombosis did not differ significantly between bifurcation lesions and non-bifurcation lesions (TLF, 7.7% vs 9.0%, respectively; adjusted P=.50). CONCLUSION The 3-year risk of TLF following PCI with R-ZES in bifurcation lesions was not significantly different from non-bifurcation lesions. However, there was an increased risk associated with bifurcation lesions during the first 30 days; beyond 30 days, bifurcation lesions and non-bifurcation lesions yielded similar 3-year outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we present a computational framework for isolating spatial patterns arising in the steady states of reaction-diffusion systems. Such systems have been used to model many different phenomena in areas such as developmental and cancer biology, cell motility and material science. Often one is interested in identifying parameters which will lead to a particular pattern. To attempt to answer this, we compute eigenpairs of the Laplacian on a variety of domains and use linear stability analysis to determine parameter values for the system that will lead to spatially inhomogeneous steady states whose patterns correspond to particular eigenfunctions. This method has previously been used on domains and surfaces where the eigenvalues and eigenfunctions are found analytically in closed form. Our contribution to this methodology is that we numerically compute eigenpairs on arbitrary domains and surfaces. Here we present various examples and demonstrate that mode isolation is straightforward especially for low eigenvalues. Additionally we see that if two or more eigenvalues are in a permissible range then the inhomogeneous steady state can be a linear combination of the respective eigenfunctions. Finally we show an example which suggests that pattern formation is robust on similar surfaces in cases that the surface either has or does not have a boundary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Regional differences in shear stress have been identified as reason for early plaque formation in vessel bifurcations. We aimed to investigate regional plaque morphology and composition using intravascular ultrasound (IVUS) and virtual histology (IVUS–VH) in coronary artery bifurcations. Methods We performed IVUS and IVUS–VH studies at coronary bifurcations to analyze segmental plaque burden and composition of different segments in relation to their orientation to the bifurcation. Results A total of 236 patients with a mean age of 59 ± 11 years (69% male) were analyzed. Plaque burden was higher at the contralateral vessel wall facing the bifurcation compared to the ipsilateral vessel wall and this difference was true for proximal and distal segments (proximal: 37 ± 12% and 45 ± 15% for segments at the ipsilateral and contralateral vessel wall, respectively, p < 0.001; distal: 37 ± 10% and 47 ± 15% for segments at the ipsilateral and contralateral vessel wall, respectively, p < 0.001). In addition, these segments exhibited a higher proportion of dense calcium and a lower proportion of fibrous tissue and fibro fatty tissue. Conclusions Segments on the contralateral wall of the bifurcation which have previously been identified as regions with low shear stress not only exhibited a higher plaque burden, but also a higher degree of calcification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Murray's law describes the optimal branching anatomy of vascular bifurcations. If Murray's law is obeyed, shear stress is constant over the bifurcation. Associations between Murray's law and intravascular ultrasound (IVUS) assessed plaque composition near coronary bifurcations have not been investigated previously.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The stress associated with providing care for a spouse diagnosed with Alzheimer's disease can have adverse effects on cardiovascular health. One potential explanation is that chronic caregiving stress may contribute to the development of atherosclerosis. The purpose of this study was to determine whether the duration that one has provided care is associated with the degree of atherosclerotic burden, as measured by carotid artery intima-media thickness (IMT). One hundred and ten Alzheimer caregivers [mean age 74 ± 8 (SD) years, 69% female] underwent in-home assessment of carotid artery IMT via B-mode ultrasonography. Data regarding medical history, blood pressure, and multiple indicators of caregiving stress were also collected. Multiple regression indicated that duration of care was positively associated with IMT measured in the internal/bifurcation segments of the carotid artery (β = 0.202, p = 0.044) independent of risk factors such as age, gender, body mass index, smoking history, sleep quality, hypertension status, and caregiving stressors. Duration of care was positively associated with IMT in the common carotid artery, but the relationship was not significant. These findings provide more evidence of the link between chronic caregiving stress and cardiovascular disease and indicate that enduring the experience of caregiving over a period of years might be associated with atherosclerotic burden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is substantial variability in the extent of the node dissection performed during radical cystectomy for bladder cancer. Here, we review the diagnostic assessment of lymph node metastasis and the prognostic and therapeutic benefit for pelvic node dissection for bladder cancer. A review of the applicable urologic literature regarding the topics of lymphadenectomy for bladder cancer was conducted. Nodal metastasis above a limited or standard template is not uncommon, with up to 16% of all nodal metastasis detected proximal to the aortic bifurcation. However, skip metastasis is extremely rare. Proteins associated purely with epithelial tissue such as cytokeratin (CK)-19, CK-20, and uroplakin II have been observed in reportedly negative nodal specimens, which indicates that routine microscopic analysis of nodal tissue may miss small foci of metastatic cancer. In addition to the surgical technique, the total number of lymph nodes removed is influenced by patient anatomy and pathologic processing and therefore may be unsuitable as a procedural quality statement. Consecutively, meticulous removal of tissue within a defined and uniformly applied template may be more relevant than absolute nodal count. Observational cohort series indicate an improved oncologic outcome for patients undergoing extensive nodal dissection. The results of two randomized controlled trials addressing the extent of nodal dissection for bladder cancer are forthcoming.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.