9 resultados para Bible. N.T. Second Peter
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We examined the effect of switching to second-line antiretroviral therapy (ART) on mortality in patients who experienced immunological failure in ART programmes without access to routine viral load monitoring in sub-Saharan Africa.
Resumo:
Unfavorable immediate or delayed results after transcatheter aortic valve implantation (TAVI) may be a consequence of bioprosthesis malfunctioning, malpositioning, embolization, or degeneration. Deployment of a second valve within the first one implanted (TAVI-in-TAV) may be a potentially helpful therapeutic strategy.
Resumo:
OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
Resumo:
PURPOSE To analyse the clinical outcome after salvage lumpectomy and multi-catheter brachytherapy (MCB) for ipsilateral breast tumour recurrence (IBTR). MATERIAL AND METHODS Between 09/00 and 09/10, 217 patients presenting an IBTR underwent lumpectomy and MCB (low, pulsed, or high-dose rate). Survival rates without second local recurrence (2nd LR), distant metastasis (DM), and overall survival (OS) were analysed as well as late effects and cosmetic results. Univariate and multivariate analyses (MVA) based on IBTR data were performed to find prognostic factors for 2nd LR, DM, and OS. RESULTS Median follow-up after the IBTR was 3.9 years [range: 1.1-10.3]. Five and 10-year actuarial 2nd LR rates were 5.6% [range: 1.5-9.5] and 7.2% [range: 2.1-12.1], respectively. Five and 10-year actuarial DM rates were 9.6% [range: 5.7-15.2] and 19.1% [range: 7.8-28.3], respectively. Five and 10-year actuarial OS rates were 88.7% [range: 83.1-94.8] and 76.4% [range: 66.9-87.3], respectively. In MVA, histological grade was prognostic factor for 2nd LR (p=0.008) and OS (p=0.02); while tumour size was prognostic factor for DM (p=0.03). G3-4 complication rate was 11%. Excellent/good cosmetic result was achieved in 85%. CONCLUSION This study suggests that in case of IBTR, lumpectomy plus MCB is feasible and effective in preventing 2nd LR with an OS rate at least equivalent to those achieved with salvage mastectomy.
Resumo:
Transapical transcatheter aortic valve implantation (TA-TAVI) is the recognized first choice surgical TAVI access. Expansion of this well-established treatment modality with subsequent broader patient inclusion has accelerated development of second-generation TA-TAVI devices. The Swiss ACURATE TA Symetis valve allows for excellent anatomical positioning, resulting in a very low incidence of paravalvular leaks. The self-expanding stent features an hourglass shape to wedge the native aortic valve annulus. A specially designed delivery system facilitates controlled release aided by tactile operator feedback. The ACURATE TA valve made of three native porcine non-coronary leaflets has received CE approval in September 2011. Since then, this valve is the third most frequently implanted TAVI device with over 1200 implants in Europe and South America. Results from the Symetis ACURATE TA™ Valve Implantation ('SAVI') Registry showed a procedural success rate of 98.0% and a survival rate of 93.2% at 30 days. This presentation provides technical considerations and detailed procedural aspects of device implantation.
Resumo:
While bisphosphonates reduce fracture risk over 3 to 5 years, the optimal duration of treatment is uncertain. In a randomized extension study (E1) of the Health Outcomes and Reduced Incidence with Zoledronic Acid Once Yearly - Pivotal Fracture Trial (HORIZON-PFT), zoledronic acid (ZOL) 5 mg annually for 6 years showed maintenance of bone mineral density (BMD), decrease in morphometric vertebral fractures, and a modest reduction in bone turnover markers (BTMs) compared with discontinuation after 3 years. To investigate the longer-term efficacy and safety of ZOL, a second extension (E2) was conducted to 9 years in which women on ZOL for 6 years in E1 were randomized to either ZOL (Z9) or placebo (Z6P3) for 3 additional years. In this multicenter, randomized, double-blind study, 190 women were randomized to Z9 (n=95) and Z6P3 (n=95). The primary endpoint was change in total hip BMD at year 9 vs. year 6 in Z9 compared with Z6P3. Other secondary endpoints included fractures, BTMs, and safety. From year 6 to 9, the mean change in total hip BMD was -0.54% in Z9 vs. -1.31% in Z6P3 (difference 0.78%; 95% confidence interval [CI]: -0.37%, 1.93%; p=0.183). BTMs showed small, non-significant increases in those who discontinued after 6 years compared with those who continued for 9 years. The number of fractures was low and did not significantly differ by treatment. While generally safe, there was a small increase in cardiac arrhythmias (combined serious and non-serious) in the Z9 group but no significant imbalance in other safety parameters. The results suggest almost all patients who have received six annual ZOL infusions can stop medication for up to 3 years with apparent maintenance of benefits. This article is protected by copyright. All rights reserved.
Resumo:
BACKGROUND Historically, percutaneous coronary intervention (PCI) of bifurcation lesions was associated with worse procedural and clinical outcomes when compared with PCI of non-bifurcation lesions. Newer generation drug-eluting stents (DES) might improve long-term clinical outcomes after bifurcation PCI. METHODS AND RESULTS The LEADERS trial was a 10-center, assessor-blind, non-inferiority, all-comers trial, randomizing 1,707 patients to treatment with a biolimus A9(TM) -eluting stent (BES) with an abluminal biodegradable polymer or a sirolimus-eluting stent (SES) with a durable polymer (ClinicalTrials.gov Identifier: NCT00389220). Five-year clinical outcomes were compared between patients with and without bifurcation lesions and between BES and SES in the bifurcation lesion subgroup. There were 497 (29%) patients with at least 1 bifurcation lesion (BES = 258; SES = 239). At 5-year follow-up, the composite endpoint of cardiac death, myocardial infarction (MI) and clinically-indicated (CI) target vessel revascularization (TVR) was observed more frequently in the bifurcation group (26.6% vs. 22.4%, P = 0.049). Within the bifurcation lesion subgroup, no differences were observed in (cardiac) death or MI rates between BES and SES. However, CI target lesion revascularization (TLR) (10.1% vs. 15.9%, P = 0.0495), and CI TVR (12.0% vs. 19.2%, P = 0.023) rates were significantly lower in the BES group. Definite/probable stent thrombosis (ST) rate was numerically lower in the BES group (3.1% vs. 5.9%, P = 0.15). Very late (>1 year) definite/probable ST rates trended to be lower with BES (0.4% vs. 3.1%, P = 0.057). CONCLUSIONS In the treatment of bifurcation lesions, use of BES led to superior long-term efficacy compared with SES. Safety outcomes were comparable between BES and SES, with an observed trend toward a lower rate of very late definite/probable ST between 1 and 5 years with the BES. © 2015 Wiley Periodicals, Inc.