58 resultados para Banach Space of Continuous Functions

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel approach for the reconstruction of spectra from Euclidean correlator data that makes close contact to modern Bayesian concepts. It is based upon an axiomatically justified dimensionless prior distribution, which in the case of constant prior function m(ω) only imprints smoothness on the reconstructed spectrum. In addition we are able to analytically integrate out the only relevant overall hyper-parameter α in the prior, removing the necessity for Gaussian approximations found e.g. in the Maximum Entropy Method. Using a quasi-Newton minimizer and high-precision arithmetic, we are then able to find the unique global extremum of P[ρ|D] in the full Nω » Nτ dimensional search space. The method actually yields gradually improving reconstruction results if the quality of the supplied input data increases, without introducing artificial peak structures, often encountered in the MEM. To support these statements we present mock data analyses for the case of zero width delta peaks and more realistic scenarios, based on the perturbative Euclidean Wilson Loop as well as the Wilson Line correlator in Coulomb gauge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A child's brain shows a remarkable ability to recover from adverse events such as stroke. Language functions recover particularly well, while visuo-spatial skills are more affected by brain damage, regardless of its localization. This study investigated the lateralization of language and visual search after childhood stroke.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synthesis of a novel bicyclo-thymidine nucleoside bearing an ester functionality at C(6') (bc(alpha-alk)-nucleosides) is reported. This nucleoside was incorporated into oligodeoxynucleotides via solid phase phosphoramidite chemistry, and the ester moiety was post-synthetically converted to an amide or a carboxy group, or was left unchanged. Thermal melting data (T-m) with complementary DNA and RNA were collected and compared to natural DNA and to bc- and bc(ox)-DNA. It was found that single incorporations of bc(alpha-alk)-nucleosides in DNA duplexes were destabilizing by 0.5 to 2.5 degrees C/mod, whereas two consecutive bc(alpha-alk)-residues were less destabilizing, and in some cases even stabilizing by 0.5 degrees C/mod. In duplexes with complementary RNA, isolated bc(alpha-alk)-residues destabilized the duplex by -1.0 to -4.0 degrees C/mod, depending on the chemical nature of the substituent, whereas two consecutive modifications were only destabilizing by 0.3-1.0 degrees C/mod. The pairing selectivity was similar to that of unmodified or bc-DNA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background and Aims: Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Subjects and Methods: Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). Results: The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Conclusions: Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For continuous outcomes measured using instruments with an established minimally important difference (MID), pooled estimates can be usefully reported in MID units. Approaches suggested thus far omit studies that used instruments without an established MID. We describe an approach that addresses this limitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was initiated to assess the quantitative impact of patient anthropometrics and dihydropyrimidine dehydrogenase (DPYD) mutations on the pharmacokinetics (PK) of 5-fluorouracil (5FU) and to explore limited sampling strategies of 5FU.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Obstructive sleep apnea (OSA) has been associated with an increased risk of atherothrombotic events. A prothrombotic state might partially explain this link. This study investigated OSA patients' day/night rhythm of several prothrombotic markers and their potential changes with therapeutic continuous positive airway pressure (CPAP).