12 resultados para BULKY

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bulky extramedullary hematopoiesis, usually detected in the thorax by imaging techniques, is a well-known complication in many types of congenital anemias. Here, we describe 12 cases of congenital dyserythropoietic anemia with extramedullary hematopoiesis which was always located in the paravertebral space of the thoracic spine and in other paraspinal regions in a few cases. All bulks were originally detected in chest radiographs and confirmed by imaging techniques such as computed tomography and/or magnetic resonance imaging. In some cases, thoracotomy was performed for suspected malignancy. Although the true prevalence is not known, paravertebral masses in patients with CDA of any type are not uncommon and should be the first differential diagnosis considered when masses adjacent to the spine are detected in this disorder.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STEPanizer is an easy-to-use computer-based software tool for the stereological assessment of digitally captured images from all kinds of microscopical (LM, TEM, LSM) and macroscopical (radiology, tomography) imaging modalities. The program design focuses on providing the user a defined workflow adapted to most basic stereological tasks. The software is compact, that is user friendly without being bulky. STEPanizer comprises the creation of test systems, the appropriate display of digital images with superimposed test systems, a scaling facility, a counting module and an export function for the transfer of results to spreadsheet programs. Here we describe the major workflow of the tool illustrating the application on two examples from transmission electron microscopy and light microscopy, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Mutations in the human gene coding for XPD lead to segmental progeria - the premature appearance of some of the phenotypes normally associated with aging - which may or may not be accompanied by increased cancer incidence. XPD is required for at least three different critical cellular functions: in addition to participating in the process of nucleotide excision repair (NER), which removes bulky DNA lesions, XPD also regulates transcription as part of the general transcription factor IIH (TFIIH) and controls cell cycle progression through its interaction with CAK, a pivotal activator of cyclin dependent kinases (CDKs). The study of inherited XPD disorders offers the opportunity to gain insights into the coordination of important cellular events and may shed light on the mechanisms that regulate the delicate equilibrium between cell proliferation and functional senescence, which is notably altered during physiological aging and in cancer. The phenotypic manifestations in the different XPD disorders are the sum of disturbances in the vital processes carried out by TFIIH and CAK. In addition, further TFIIH- and CAK-independent cellular activities of XPD may also play a role. This, added to the complex feedback networks that are in place to guarantee the coordination between cell cycle, DNA repair and transcription, complicates the interpretation of clinical observations. While results obtained from patient cell isolates as well as from murine models have been elementary in revealing such complexity, the Drosophila embryo has proven useful to analyze the role of XPD as a cell cycle regulator independently from its other cellular functions. Together with data from the biochemical and structural analysis of XPD and of the TFIIH complex these results combine into a new picture of the XPD activities that provides ground for a better understanding of the patophysiology of XPD diseases and for future development of diagnostic and therapeutic tools.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grid (or sieve) therapy ("Gitter-" oder "Siebtherapie"), spatially fractionated kilo- and megavolt X-ray therapy, was invented in 1909 by Alban Köhler, a radiologist in Wiesbaden, Germany. He tested it on several patients before 1913 using approximately 60-70kV Hittorf-Crookes tubes. Köhler pushed the X-ray tube's lead-shielded housing against a stiff grid of 1 mm-square iron wires woven 3.0-3.5mm on center, taped tightly to the skin over a thin chamois. Numerous islets unshielded by iron in the pressure-blanched skin were irradiated with up to about 6 erythema doses (ED). The skin was then thoroughly cleansed, disinfected, and bandaged; delayed punctate necrosis healed in several weeks. Although grid therapy was disparaged or ignored until the 1930s, it has been used successfully since then to shrink bulky malignancies. Also, advanced cancers in rats and mice have been mitigated or ablated using Köhler's concept since the early 1990s by unidirectional or stereotactic exposure to an array of nearly parallel microplanar (25-75μm-wide) beams of very intense, moderately hard (median energy approximately 100 keV) synchrotron-generated X rays spaced 0.1-0.4mm on center. Such beams maintain sharp edges at high doses well beneath the skin yet confer little toxicity. They could palliate some otherwise intractable malignancies, perhaps in young children too, with tolerable sequelae. There are plans for such studies in larger animals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using multicast communication in Wireless Sensor Networks (WSNs) is an efficient way to disseminate the same data (from one sender) to multiple receivers, e.g., transmitting code updates to a group of sensor nodes. Due to the nature of code update traffic a multicast protocol has to support bulky traffic and end-to-end reliability. We are interested in an energy-efficient multicast protocol due to the limited resources of wireless sensor nodes. Current data dissemination schemes do not fulfill the above requirements. In order to close the gap, we designed and implemented the SNOMC (Sensor Node Overlay Multicast) protocol. It is an overlay multicast protocol, which supports reliable, time-efficient, and energy-efficient data dissemination of bulky data from one sender to many receivers. To ensure end-to-end reliability, SNOMC uses a NACK-based reliability mechanism with different caching strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONCLUSION: Endoscopic resection of laryngeal and tracheal lesions using the microdebrider is a safe, accurate and reliable method. OBJECTIVE: The microdebrider is an important tool for endoscopic nasal and sinus surgery and over the last few years a powered blade with a long shaft has been developed for endoscopic laryngeal and tracheal surgery. The aim of this non-randomized prospective study was to determine the advantages and disadvantages of the microdebrider for treating patients with different laryngeal and tracheal pathologies. MATERIAL AND METHODS: The laryngeal microdebrider was used under endoscopic control in 37 patients. In 29 cases a benign laryngeal lesion was removed endoscopically. In four patients debulking of a malignant obstructive endolaryngeal tumor was performed in order to avoid a tracheotomy. In four cases a bulky obstructing endotracheal lesion was removed. RESULTS: All laryngotracheal lesions could be removed, and this was facilitated by the use of angled rigid telescopes and the laryngeal blade. No traumatic lesions to normal laryngeal tissue occurred as a result of use of the microdebrider and no postoperative endolaryngeal bleeding was observed. The histological diagnosis of the biopsies taken with the microdebrider was accurate in every case. In three of the four cases with obstructive laryngeal malignancies, a tracheotomy was avoided until definitive therapy was undertaken. Normal breathing was restored in all patients with endotracheal lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the outcomes and patterns of failure in solitary plasmacytoma (SP). METHODS AND MATERIALS: The data from 258 patients with bone (n = 206) or extramedullary (n = 52) SP without evidence of multiple myeloma (MM) were collected. A histopathologic diagnosis was obtained for all patients. Most (n = 214) of the patients received radiotherapy (RT) alone; 34 received chemotherapy and RT, and 8 surgery alone. The median radiation dose was 40 Gy. The median follow-up was 56 months (range 7-245). RESULTS: The median time to MM development was 21 months (range 2-135), with a 5-year probability of 45%. The 5-year overall survival, disease-free survival, and local control rate was 74%, 50%, and 86%, respectively. On multivariate analyses, the favorable factors were younger age and tumor size <4 cm for survival; younger age, extramedullary localization, and RT for disease-free survival; and small tumor and RT for local control. Bone localization was the only predictor of MM development. No dose-response relationship was found for doses >30 Gy, even for larger tumors. CONCLUSION: Progression to MM remains the main problem. Patients with extramedullary SP had the best outcomes, especially when treated with moderate-dose RT. Chemotherapy and/or novel therapies should be investigated for bone or bulky extramedullary SP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe synthesis, conformational studies, and binding to the five somatostatin receptors (sst 1-5) of a few analogues of the cyclic octapeptide octreotide (1), where the disulfide bridge was replaced by a dicarba group. These analogues were prepared by on-resin RCM of linear hepta-peptides containing two allylglycine residues; first- and second-generation Grubbs catalyst efficiencies were compared. The C=C bridge was hydrogenated via two different methods. Binding experiments showed that two analogues had good affinity and high selectivity for the sst5 receptor. Three-dimensional structures of the active analogues were determined by (1)H NMR spectroscopy. Conformation-affinity relationships confirmed the importance of D-Phe(2) orientation for sst2 affinity. Moreover, helical propensities well correlates with the peptide sst5 affinity. The presence of the bulky aromatic side chain of Tyr(Bzl)(10) favored the formation of a 3(10)-helix and enhanced the sst5 selectivity suppressing the sst2 affinity. Finally, a new pharmacophore model for the sst5 was developed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Fixation of periprosthetic hip fractures with intracortical anchorage might not be feasible in cases with bulky implants and/or poor bone stock. METHODS Rotational stability of new plate inserts with extracortical anchorage for cerclage fixation was measured and compared to the stability found using a standard technique in a biomechanical setup using a torsion testing machine. In a synthetic PUR bone model, transverse fractures were fixed distally using screws and proximally by wire cerclages attached to the plates using "new" (extracortical anchorage) or "standard" (intracortical anchorage) plate inserts. Time to fracture consolidation and complications were assessed in a consecutive series of 18 patients (18 female; mean age 81 years, range 55-92) with periprosthetic hip fractures (ten type B1, eight type C-Vancouver) treated with the new device between July 2003 and July 2010. RESULTS The "new" device showed a higher rotational stability than the "standard" technique (p < 0.001). Fractures showed radiographic consolidation after 14 ± 5 weeks (mean ± SD) postoperatively in patients. Revision surgery was necessary in four patients, unrelated to the new technique. CONCLUSION In periprosthetic hip fractures in which fixation with intracortical anchorage using conventional means might be difficult due to bulky revision stems and/or poor bone stock, the new device may be an addition to the range of existing implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Various applications for the purposes of event detection, localization, and monitoring can benefit from the use of wireless sensor networks (WSNs). Wireless sensor networks are generally easy to deploy, with flexible topology and can support diversity of tasks thanks to the large variety of sensors that can be attached to the wireless sensor nodes. To guarantee the efficient operation of such a heterogeneous wireless sensor networks during its lifetime an appropriate management is necessary. Typically, there are three management tasks, namely monitoring, (re) configuration, and code updating. On the one hand, status information, such as battery state and node connectivity, of both the wireless sensor network and the sensor nodes has to be monitored. And on the other hand, sensor nodes have to be (re)configured, e.g., setting the sensing interval. Most importantly, new applications have to be deployed as well as bug fixes have to be applied during the network lifetime. All management tasks have to be performed in a reliable, time- and energy-efficient manner. The ability to disseminate data from one sender to multiple receivers in a reliable, time- and energy-efficient manner is critical for the execution of the management tasks, especially for code updating. Using multicast communication in wireless sensor networks is an efficient way to handle such traffic pattern. Due to the nature of code updates a multicast protocol has to support bulky traffic and endto-end reliability. Further, the limited resources of wireless sensor nodes demand an energy-efficient operation of the multicast protocol. Current data dissemination schemes do not fulfil all of the above requirements. In order to close the gap, we designed the Sensor Node Overlay Multicast (SNOMC) protocol such that to support a reliable, time-efficient and energy-efficient dissemination of data from one sender node to multiple receivers. In contrast to other multicast transport protocols, which do not support reliability mechanisms, SNOMC supports end-to-end reliability using a NACK-based reliability mechanism. The mechanism is simple and easy to implement and can significantly reduce the number of transmissions. It is complemented by a data acknowledgement after successful reception of all data fragments by the receiver nodes. In SNOMC three different caching strategies are integrated for an efficient handling of necessary retransmissions, namely, caching on each intermediate node, caching on branching nodes, or caching only on the sender node. Moreover, an option was included to pro-actively request missing fragments. SNOMC was evaluated both in the OMNeT++ simulator and in our in-house real-world testbed and compared to a number of common data dissemination protocols, such as Flooding, MPR, TinyCubus, PSFQ, and both UDP and TCP. The results showed that SNOMC outperforms the selected protocols in terms of transmission time, number of transmitted packets, and energy-consumption. Moreover, we showed that SNOMC performs well with different underlying MAC protocols, which support different levels of reliability and energy-efficiency. Thus, SNOMC can offer a robust, high-performing solution for the efficient distribution of code updates and management information in a wireless sensor network. To address the three management tasks, in this thesis we developed the Management Architecture for Wireless Sensor Networks (MARWIS). MARWIS is specifically designed for the management of heterogeneous wireless sensor networks. A distinguished feature of its design is the use of wireless mesh nodes as backbone, which enables diverse communication platforms and offloading functionality from the sensor nodes to the mesh nodes. This hierarchical architecture allows for efficient operation of the management tasks, due to the organisation of the sensor nodes into small sub-networks each managed by a mesh node. Furthermore, we developed a intuitive -based graphical user interface, which allows non-expert users to easily perform management tasks in the network. In contrast to other management frameworks, such as Mate, MANNA, TinyCubus, or code dissemination protocols, such as Impala, Trickle, and Deluge, MARWIS offers an integrated solution monitoring, configuration and code updating of sensor nodes. Integration of SNOMC into MARWIS further increases performance efficiency of the management tasks. To our knowledge, our approach is the first one, which offers a combination of a management architecture with an efficient overlay multicast transport protocol. This combination of SNOMC and MARWIS supports reliably, time- and energy-efficient operation of a heterogeneous wireless sensor network.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

10.1002/hlca.200390311.abs A series of oligonucleotides containing (5′S)-5′-C-butyl- and (5′S)-5′-C-isopentyl-substituted 2′-deoxyribonucleosides were designed, prepared, and characterized with the intention to explore alkyl-zipper formation between opposing alkyl chains across the minor groove of oligonucleotide duplexes as a means to modulate DNA-duplex stability. From four possible arrangements of the alkyl groups that differ in the density of packing of the alkyl chains across the minor groove, three (duplex types I–III, Fig. 2) could experimentally be realized and their duplex-forming properties analyzed by UV-melting curves, CD spectroscopy, and isothermal titration calorimetry (ITC), as well as by molecular modeling. The results show that all arrangements of alkyl residues within the minor groove of DNA are thermally destabilizing by 1.5–3°/modification in Tm. We found that, within the proposed duplexes with more loosely packed alkyl groups (type-III duplexes), accommodation of alkyl residues without extended distorsion of the helical parameters of B-DNA is possible but does not lead to higher thermodynamic stability. The more densely packed and more unevenly distributed arrangement (type-II duplexes) seems to suffer from ecliptic positioning of opposite alkyl groups, which might account for a systematic negative contribution to stability due to steric interactions. The decreased stability in the type-III duplexes described here may be due either to missing hydrophobic interactions of the alkyl groups (not bulky enough to make close contacts), or to an overcompensation of favorable alkyl-zipper formation presumably by loss of structured H2O in the minor groove.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.