10 resultados para Axial pre-loading

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

50.00% 50.00%

Publicador:

Resumo:

INTRODUCTION An accurate description of the biomechanical behavior of the spine is crucial for the planning of scoliotic surgical correction as well as for the understanding of degenerative spine disorders. The current clinical assessments of spinal mechanics such as side-bending or fulcrum-bending tests rely on the displacement of the spine observed during motion of the patient. Since these tests focused solely on the spinal kinematics without considering mechanical loads, no quantification of the mechanical flexibility of the spine can be provided. METHODS A spinal suspension test (SST) has been developed to simultaneously monitor the force applied on the spine and the induced vertebral displacements. The system relies on cervical elevation of the patient and orthogonal radiographic images are used to measure the position of the vertebras. The system has been used to quantify the spinal flexibility on five AIS patients. RESULTS Based on the SST, the overall spinal flexibility varied between 0.3 °/Nm for the patient with the stiffer curve and 2 °/Nm for the less rigid curve. A linear correlation was observed between the overall spinal flexibility and the change in Cobb angle. In addition, the segmental flexibility calculated for five segments around the apex was 0.13 ± 0.07 °/Nm, which is similar to intra-operative stiffness measurements previously published. CONCLUSIONS In summary, the SST seems suitable to provide pre-operative information on the complex functional behavior and stiffness of spinal segments under physiological loading conditions. Such tools will become increasingly important in the future due to the ever-increasing complexity of the surgical instrumentation and procedures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to assess the safety of the concurrent administration of a clopidogrel and prasugrel loading dose in patients undergoing primary percutaneous coronary intervention. BACKGROUND Prasugrel is one of the preferred P2Y12 platelet receptor antagonists for ST-segment elevation myocardial infarction patients. The use of prasugrel was evaluated clinically in clopidogrel-naive patients. METHODS Between September 2009 and October 2012, a total of 2,023 STEMI patients were enrolled in the COMFORTABLE (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI]) and the SPUM-ACS (Inflammation and Acute Coronary Syndromes) studies. Patients receiving a prasugrel loading dose were divided into 2 groups: 1) clopidogrel and a subsequent prasugrel loading dose; and 2) a prasugrel loading dose. The primary safety endpoint was Bleeding Academic Research Consortium types 3 to 5 bleeding in hospital at 30 days. RESULTS Of 2,023 patients undergoing primary percutaneous coronary intervention, 427 (21.1%) received clopidogrel and a subsequent prasugrel loading dose, 447 (22.1%) received a prasugrel loading dose alone, and the remaining received clopidogrel only. At 30 days, the primary safety endpoint was observed in 1.9% of those receiving clopidogrel and a subsequent prasugrel loading dose and 3.4% of those receiving a prasugrel loading dose alone (adjusted hazard ratio [HR]: 0.57; 95% confidence interval [CI]: 0.25 to 1.30, p = 0.18). The HAS-BLED (hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, labile international normalized ratio, elderly, drugs/alcohol concomitantly) bleeding score tended to be higher in prasugrel-treated patients (p = 0.076). The primary safety endpoint results, however, remained unchanged after adjustment for these differences (clopidogrel and a subsequent prasugrel loading dose vs. prasugrel only; HR: 0.54 [95% CI: 0.23 to 1.27], p = 0.16). No differences in the composite of cardiac death, myocardial infarction, or stroke were observed at 30 days (adjusted HR: 0.66, 95% CI: 0.27 to 1.62, p = 0.36). CONCLUSIONS This observational, nonrandomized study of ST-segment elevation myocardial infarction patients suggests that the administration of a loading dose of prasugrel in patients pre-treated with a loading dose of clopidogrel is not associated with an excess of major bleeding events. (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI] [COMFORTABLE]; NCT00962416; and Inflammation and Acute Coronary Syndromes [SPUM-ACS]; NCT01000701).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Loading is important to maintain the balance of matrix turnover in the intervertebral disc (IVD). Daily cyclic diurnal assists in the transport of large soluble factors across the IVD and its surrounding circulation and applies direct and indirect stimulus to disc cells. Acute mechanical injury and accumulated overloading, however, could induce disc degeneration. Recently, there is more information available on how cyclic loading, especially axial compression and hydrostatic pressure, affects IVD cell biology. This review summarises recent studies on the response of the IVD and stem cells to applied cyclic compression and hydrostatic pressure. These studies investigate the possible role of loading in the initiation and progression of disc degeneration as well as quantifying a physiological loading condition for the study of disc degeneration biological therapy. Subsequently, a possible physiological/beneficial loading range is proposed. This physiological/beneficial loading could provide insight into how to design loading regimes in specific system for the testing of various biological therapies such as cell therapy, chemical therapy or tissue engineering constructs to achieve a better final outcome. In addition, the parameter space of 'physiological' loading may also be an important factor for the differentiation of stem cells towards most ideally 'discogenic' cells for tissue engineering purpose.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the multidisciplinary findings in a pre-Columbian mummy head from Southern Peru (Cahuachi, Nazca civilisation, radiocarbon dating between 120 and 750 AD) of a mature male individual (40-60 years) with the first two vertebrae attached in pathological position. Accordingly, the atlanto-axial transition (C1/C2) was significantly rotated and dislocated at 38° angle associated with a bulging brownish mass that considerably reduced the spinal canal by circa 60%. Using surface microscopy, endoscopy, high-resolution multi-slice computer tomography, paleohistology and immunohistochemistry, we identified an extensive epidural hematoma of the upper cervical spinal canal-extending into the skull cavity-obviously due to a rupture of the left vertebral artery at its transition between atlas and skull base. There were no signs of fractures of the skull or vertebrae. Histological and immunohistochemical examinations clearly identified dura, brain residues and densely packed corpuscular elements that proved to represent fresh epidural hematoma. Subsequent biochemical analysis provided no evidence for pre-mortal cocaine consumption. Stable isotope analysis, however, revealed significant and repeated changes in the nutrition during his last 9 months, suggesting high mobility. Finally, the significant narrowing of the rotational atlanto-axial dislocation and the epidural hematoma probably caused compression of the spinal cord and the medulla oblongata with subsequent respiratory arrest. In conclusion, we suggest that the man died within a short period of time (probably few minutes) in an upright position with the head rotated rapidly to the right side. In paleopathologic literature, trauma to the upper cervical spine has as yet only very rarely been described, and dislocation of the vertebral bodies has not been presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to the inherent limitations of DXA, assessment of the biomechanical properties of vertebral bodies relies increasingly on CT-based finite element (FE) models, but these often use simplistic material behaviour and/or single loading cases. In this study, we applied a novel constitutive law for bone elasticity, plasticity and damage to FE models created from coarsened pQCT images of human vertebrae, and compared vertebral stiffness, strength and damage accumulation for axial compression, anterior flexion and a combination of these two cases. FE axial stiffness and strength correlated with experiments and were linearly related to flexion properties. In all loading modes, damage localised preferentially in the trabecular compartment. Damage for the combined loading was higher than cumulated damage produced by individual compression and flexion. In conclusion, this FE method predicts stiffness and strength of vertebral bodies from CT images with clinical resolution and provides insight into damage accumulation in various loading modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To evaluate the stabilizing function of atlanto-axial ligaments in dogs. STUDY DESIGN Cadaveric biomechanical study. ANIMALS Beagle dog cadavers (n = 10). METHODS The craniocervical region was collected from 10 Beagle cadavers, and the occipito-atlanto-axial region was prepared and freed from the surrounding muscles. Care was taken to preserve integrity of the atlantoaxial ligaments and atlantoaxial joint capsule. The atlanto-occipital joints were blocked with 2 diverging transarticular 1.8 mm positive threaded K-wires. Specimen extremities were embedded in polymethylmethacrylate (PMMA) and mounted on a simulator testing shear load at the atlantoaxial joint. Range of motion (ROM) and neutral zone (NZ) were determined with all ligaments intact, after cutting the apical ligament, both alar ligaments, the transverse ligaments and finally after cutting the dorsal atlantoaxial ligament. RESULTS ROM increased similarly and stepwise during testing. The most significant increase was observed after transection of the alar ligaments. CONCLUSION The alar ligaments seem to be the most important ligamentous structures for stabilization of the atlantoaxial joint under shear load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer tomography (CT)-based finite element (FE) models of vertebral bodies assess fracture load in vitro better than dual energy X-ray absorptiometry, but boundary conditions affect stress distribution under the endplates that may influence ultimate load and damage localisation under post-yield strains. Therefore, HRpQCT-based homogenised FE models of 12 vertebral bodies were subjected to axial compression with two distinct boundary conditions: embedding in polymethylmethalcrylate (PMMA) and bonding to a healthy intervertebral disc (IVD) with distinct hyperelastic properties for nucleus and annulus. Bone volume fraction and fabric assessed from HRpQCT data were used to determine the elastic, plastic and damage behaviour of bone. Ultimate forces obtained with PMMA were 22% higher than with IVD but correlated highly (R2 = 0.99). At ultimate force, distinct fractions of damage were computed in the endplates (PMMA: 6%, IVD: 70%), cortex and trabecular sub-regions, which confirms previous observations that in contrast to PMMA embedding, failure initiated underneath the nuclei in healthy IVDs. In conclusion, axial loading of vertebral bodies via PMMA embedding versus healthy IVD overestimates ultimate load and leads to distinct damage localisation and failure pattern.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The spine is routinely subjected to repetitive complex loading consisting of axial compression, torsion, flexion and extension. Mechanical loading is one of the important causes of spinal diseases, including disc herniation and disc degeneration. It is known that static and dynamic compression can lead to progressive disc degeneration, but little is known about the mechanobiology of the disc subjected to combined dynamic compression and torsion. Therefore, the purpose of this study was to compare the mechanobiology of the intervertebral disc when subjected to combined dynamic compression and axial torsion or pure dynamic compression or axial torsion using organ culture. We applied four different loading modalities 1. control: no loading (NL), 2. cyclic compression (CC), 3. cyclic torsion (CT), and 4. combined cyclic compression and torsion (CCT) on bovine caudal disc explants using our custom made dynamic loading bioreactor for disc organ culture. Loads were applied for 8 h/day and continued for 14 days, all at a physiological magnitude and frequency. Our results provided strong evidence that complex loading induced a stronger degree of disc degeneration compared to one degree of freedom loading. In the CCT group, less than 10\% nucleus pulposus (NP) cells survived the 14 days of loading, while cell viabilities were maintained above 70\% in the NP of all the other three groups and in the annulus fibrosus (AF) of all the groups. Gene expression analysis revealed a strong up-regulation in matrix genes and matrix remodeling genes in the AF of the CCT group. Cell apoptotic activity and glycosaminoglycan content were also quantified but there were no statistically significant differences found. Cell morphology in the NP of the CCT was changed, as shown by histological evaluation. Our results stress the importance of complex loading on the initiation and progression of disc degeneration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hydrogels have been described as ideal scaffolds for cells of 3D tissue constructs and hold strong promises with respect to in vitro 3D-cell-culture, where cells are isolated from native extracellular matrix (ECM). Synthesized polyethyleneglycol (PEG) hydrogels are appealing with regard to potential for cell therapy or as vehicles for drug delivery or even to regenerate tissue with similar hydrogel-like properties such as the nucleus pulposus of the intervertebral disc (IVD). Here, we tested whether incorporation of RGD motive would hinder discogenic differentiation of primary bone marrow-derived human mesenchymal stem cells (hMSCs) but favor proliferation of undifferentiated hMSCs. HMSCs were embedded in +RGD containing or without RGD PEG hydrogel and pre-conditioned with or without growth and differentiation factor-5 (rhGDF-5) for 13 days. Afterwards, all hMSCs-PEG gels were subsequently cyclically loaded (15% strain, 1Hz) for 5 consecutive days in a bioreactor to generate an IVD-like phenotype. Higher metabolic activity (resazurin assay) was found in groups with rhGDF5 in both gel types with and without RGD. Cell viability and morphology measured by confocal laser microscopy and DNA content showed decreased values (~60%) after 18 days of culture. Real-time RT-PCR of an array of 15 key genes suspected to be distinctive for IVD cells revealed moderate response to rhGDF5 and mechanical loading as also shown by histology staining. Preconditioning and mechanical loading showed relatively moderate responses revealed from both RT-PCR and histology although hMSCs were demonstrated to be potent to differentiate into chondrocyte-progenitor cells in micro- mass and 3D alginate bead culture.