31 resultados para Average waiting time
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
AIMS: To assess waiting times for cataract surgery and their acceptance in European countries, and to find explanatory, country-specific health indicators. METHODS: Using data from the survey of health, ageing and retirement in Europe (SHARE), waiting times for cataract surgery of 245 respondents in ten countries were analysed with the help of linear regression. The influence of four country specific health indicators on waiting times was studied by multiple linear regression. The influence of waiting time and country on the wish to have surgery performed earlier was determined through logistic regression. Additional information was obtained for each country from opinion leaders in the field of cataract surgery. RESULTS: Waiting times differed significantly (p<0.001) between the ten analysed European countries. The length of wait was significantly influenced by the total expenditure on health (p<0.01) but not by the other country specific health indicators. The wish to have surgery performed earlier was determined by the length of wait (p<0.001) but not by the country where surgery was performed. CONCLUSION: The length of wait is influenced by the total expenditure on health, but not by the rate of public expenditure on health, by the physician density or by the acute bed density. The wish to have surgery performed earlier depends on the length of wait for surgery and is not influenced by the country.
Resumo:
Background Patients' health related quality of life (HRQoL) has rarely been systematically monitored in general practice. Electronic tools and practice training might facilitate the routine application of HRQoL questionnaires. Thorough piloting of innovative procedures is strongly recommended before the conduction of large-scale studies. Therefore, we aimed to assess i) the feasibility and acceptance of HRQoL assessment using tablet computers in general practice, ii) the perceived practical utility of HRQoL results and iii) to identify possible barriers hindering wider application of this approach. Methods Two HRQoL questionnaires (St. George's Respiratory Questionnaire SGRQ and EORTC QLQ-C30) were electronically presented on portable tablet computers. Wireless network (WLAN) integration into practice computer systems of 14 German general practices with varying infrastructure allowed automatic data exchange and the generation of a printout or a PDF file. General practitioners (GPs) and practice assistants were trained in a 1-hour course, after which they could invite patients with chronic diseases to fill in the electronic questionnaire during their waiting time. We surveyed patients, practice assistants and GPs regarding their acceptance of this tool in semi-structured telephone interviews. The number of assessments, HRQoL results and interview responses were analysed using quantitative and qualitative methods. Results Over the course of 1 year, 523 patients filled in the electronic questionnaires (1–5 times; 664 total assessments). On average, results showed specific HRQoL impairments, e.g. with respect to fatigue, pain and sleep disturbances. The number of electronic assessments varied substantially between practices. A total of 280 patients, 27 practice assistants and 17 GPs participated in the telephone interviews. Almost all GPs (16/17 = 94%; 95% CI = 73–99%), most practice assistants (19/27 = 70%; 95% CI = 50–86%) and the majority of patients (240/280 = 86%; 95% CI = 82–91%) indicated that they would welcome the use of electronic HRQoL questionnaires in the future. GPs mentioned availability of local health services (e.g. supportive, physiotherapy) (mean: 9.4 ± 1.0 SD; scale: 1 – 10), sufficient extra time (8.9 ± 1.5) and easy interpretation of HRQoL results (8.6 ± 1.6) as the most important prerequisites for their use. They believed HRQoL assessment facilitated both communication and follow up of patients' conditions. Practice assistants emphasised that this process demonstrated an extra commitment to patient centred care; patients viewed it as a tool, which contributed to the physicians' understanding of their personal condition and circumstances. Conclusion This pilot study indicates that electronic HRQoL assessment is technically feasible in general practices. It can provide clinically significant information, which can either be used in the consultation for routine care, or for research purposes. While GPs, practice assistants and patients were generally positive about the electronic procedure, several barriers (e.g. practices' lack of time and routine in HRQoL assessment) need to be overcome to enable broader application of electronic questionnaires in every day medical practice.
Resumo:
The selection of liver transplant candidates with hepatocellular carcinoma (HCC) is currently validated based on Milan criteria. The use of extended criteria has remained a matter of debate, mainly because of the absence of prospective validation. The present prospective study recruited patients according to the previously proposed Total Tumor Volume (TTV ≤115 cm(3) )/alpha fetoprotein (AFP ≤400 ng/ml) score. Patients with AFP >400 ng/ml were excluded, and as such the Milan group was modified to include only patients with AFP <400 ng/ml; these patients were compared to patients beyond Milan, but within TTV/AFP. From January 2007 to March 2013, 233 patients with HCC were listed for liver transplantation. Of them, 195 patients were within Milan, and 38 beyond Milan but within TTV/AFP. The average follow-up from listing was 33,9 ±24,9 months. The risk of drop-out was higher for patients beyond Milan but within TTV/AFP (16/38, 42,1%), than for patients within Milan (49/195, 25,1%, p=0,033). In parallel, intent-to-treat survival from listing was lower in the patients beyond Milan (53,8% vs. 71,6% at four years, p<0,001). After a median waiting time of 8 months, 166 patients were transplanted, 134 patients within Milan criteria, and 32 beyond Milan but within TTV/AFP. They demonstrated acceptable and similar recurrence rates (4,5% vs. 9,4%, p=0,138) and post-transplant survivals (78,7% vs. 74,6% at four years, p=0,932). CONCLUSION Based on the present prospective study, HCC liver transplant candidate selection could be expanded to the TTV (≤115 cm(3) )/AFP (≤400 ng/ml) criteria in centers with at least 8-month waiting time. An increased risk of drop-out on the waiting list can be expected but with equivalent and satisfactory post-transplant survival. This article is protected by copyright. All rights reserved.
Resumo:
The Lapeyre-Triflo FURTIVA valve aims at combining the favorable hemodynamics of bioprosthetic heart valves with the durability of mechanical heart valves (MHVs). The pivoting region of MHVs is hemodynamically of special interest as it may be a region of high shear stresses, combined with areas of flow stagnation. Here, platelets can be activated and may form a thrombus which in the most severe case can compromise leaflet mobility. In this study we set up an experiment to replicate the pulsatile flow in the aortic root and to study the flow in the pivoting region under physiological hemodynamic conditions (CO = 4.5 L/min / CO = 3.0 L/min, f = 60 BPM). It was found that the flow velocity in the pivoting region could reach values close to that of the bulk flow during systole. At the onset of diastole the three valve leaflets closed in a very synchronous manner within an average closing time of 55 ms which is much slower than what has been measured for traditional bileaflet MHVs. Hot spots for elevated viscous shear stresses were found at the flanges of the housing and the tips of the leaflet ears. Systolic VSS was maximal during mid-systole and reached levels of up to 40 Pa.
Resumo:
This paper describes a method for DRR generation as well as for volume gradients projection using hardware accelerated 2D texture mapping and accumulation buffering and demonstrates its application in 2D-3D registration of X-ray fluoroscopy to CT images. The robustness of the present registration scheme are guaranteed by taking advantage of a coarse-to-fine processing of the volume/image pyramids based on cubic B-splines. A human cadaveric spine specimen together with its ground truth was used to compare the present scheme with a purely software-based scheme in three aspects: accuracy, speed, and capture ranges. Our experiments revealed an equivalent accuracy and capture ranges but with much shorter registration time with the present scheme. More specifically, the results showed 0.8 mm average target registration error, 55 second average execution time per registration, and 10 mm and 10° capture ranges for the present scheme when tested on a 3.0 GHz Pentium 4 computer.
Resumo:
In order to assess the clinical relevance of a slice-to-volume registration algorithm, this technique was compared to manual registration. Reformatted images obtained from a diagnostic CT examination of the lower abdomen were reviewed and manually registered by 41 individuals. The results were refined by the algorithm. Furthermore, a fully automatic registration of the single slices to the whole CT examination, without manual initialization, was also performed. The manual registration error for rotation and translation was found to be 2.7+/-2.8 degrees and 4.0+/-2.5 mm. The automated registration algorithm significantly reduced the registration error to 1.6+/-2.6 degrees and 1.3+/-1.6 mm (p = 0.01). In 3 of 41 (7.3%) registration cases, the automated registration algorithm failed completely. On average, the time required for manual registration was 213+/-197 s; automatic registration took 82+/-15 s. Registration was also performed without any human interaction. The resulting registration error of the algorithm without manual pre-registration was found to be 2.9+/-2.9 degrees and 1.1+/-0.2 mm. Here, a registration took 91+/-6 s, on average. Overall, the automated registration algorithm improved the accuracy of manual registration by 59% in rotation and 325% in translation. The absolute values are well within a clinically relevant range.
Resumo:
This paper deals with an event-bus tour booked by Bollywood film fans. During the tour, the participants visit selected locations of famous Bollywood films at various sites in Switzerland. Moreover, the tour includes stops for lunch and shopping. Each day, up to five buses operate the tour; for organizational reasons, two or more buses cannot stay at the same location simultaneously. The planning problem is how to compute a feasible schedule for each bus such that the total waiting time (primary objective) and the total travel time (secondary objective) are minimized. We formulate this problem as a mixed-integer linear program, and we report on computational results obtained with the Gurobi solver.
Resumo:
OBJECTIVES This study reports a series of pitfalls, premature failures and explantations of the third-generation Freedom SOLO (FS) bovine pericardial stentless valve. METHODS A total of 149 patients underwent aortic valve replacement using the FS. Follow-up was 100% complete with an average observation time of 5.5 ± 2.3 years (maximum 8.7 years) and a total of 825 patient-years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. RESULTS Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92, 88, 80, 70 and 62%, respectively. Fourteen prostheses required explantation due to valve-independent dysfunction (n = 5; i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n = 4 and severe stenosis, n = 5). Thus, freedom from explantation at 5, 6, 7, 8 and 9 years was 95, 94, 91, 81 and 72%, respectively. An acute vertical tear along the non-coronary/right coronary commissure to the base occurred at a mean of 6.0 years (range 4.3-7.3 years) and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years (range 7.0-8.3 years) due to severe functional stenosis and gross calcification that included the entire aortic root. CONCLUSIONS The FS stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6-7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.
Resumo:
BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.
Resumo:
This paper deals with “The Enchanted Journey,” which is a daily event tour booked by Bollywood-film fans. During the tour, the participants visit original sites of famous Bollywood films at various locations in Switzerland; moreover, the tour includes stops for lunch and shopping. Each day, up to five buses operate the tour. For operational reasons, however, two or more buses cannot stay at the same location simultaneously. Further operative constraints include time windows for all activities and precedence constraints between some activities. The planning problem is how to compute a feasible schedule for each bus. We implement a two-step hierarchical approach. In the first step, we minimize the total waiting time; in the second step, we minimize the total travel time of all buses. We present a basic formulation of this problem as a mixed-integer linear program. We enhance this basic formulation by symmetry-breaking constraints, which reduces the search space without loss of generality. We report on computational results obtained with the Gurobi Solver. Our numerical results show that all relevant problem instances can be solved using the basic formulation within reasonable CPU time, and that the symmetry-breaking constraints reduce that CPU time considerably.
Resumo:
Terbium-149 is among the most interesting therapeutic nuclides for medical applications. It decays by emission of short-range α-particles (Eα = 3.967 MeV) with a half-life of 4.12 h. The goal of this study was to investigate the anticancer efficacy of a 149Tb-labeled DOTA-folate conjugate (cm09) using folate receptor (FR)-positive cancer cells in vitro and in tumor-bearing mice. 149Tb was produced at the ISOLDE facility at CERN. Radiolabeling of cm09 with purified 149Tb resulted in a specific activity of ~1.2 MBq/nmol. In vitro assays performed with 149Tb-cm09 revealed a reduced KB cell viability in a FR-specific and activity concentration-dependent manner. Tumor-bearing mice were injected with saline only (group A) or with 149Tb-cm09 (group B: 2.2 MBq; group C: 3.0 MBq). A significant tumor growth delay was found in treated animals resulting in an increased average survival time of mice which received 149Tb-cm09 (B: 30.5 d; C: 43 d) compared to untreated controls (A: 21 d). Analysis of blood parameters revealed no signs of acute toxicity to the kidneys or liver in treated mice over the time of investigation. These results demonstrated the potential of folate-based α-radionuclide therapy in tumor-bearing mice.
Resumo:
BACKGROUND The Journey bicruciate substituting (BCS) total knee replacement (TKR) is intended to improve knee kinematics by more closely approximating the surfaces of a normal knee. The purpose of this analysis was to address the safety of Journey BCS knees by studying early complication and revision rates in a consecutive case series. METHODS Between December 2006 and May 2011, a single surgeon implanted 226 Journey BCS total knee prostheses in 191 patients (124 women, 67 men) who were eligible for study. Mean age at surgery was 68 years (41-85 years).Outcome measures were early complications and minor and major revision rates. All complications were considered, irrespective of whether conservative treatment or revision was required. RESULTS The average implantation time was 3.5 years (range 1.3-5.8 years). Thirty-three complications (14.6% of 226 knees) required minor or major revision surgery in 25 patients. The remaining eight patients were treated conservatively. Sixteen minor revisions were performed in 12 patients. Thirteen major revisions were required in 13 patients, which results in a rate of 1.65 major revisions per 100 component years. The linear trend of the early complication rate by treatment year was not significant (p = .22).Multivariate logistic regression showed no significant predictors for the occurrence of a complication or for revision surgery. A tendency towards higher complication rates was observed in female patients, although it was not significant (p = .066). CONCLUSIONS The complication and revision rates of the Journey BCS knee implant are high in comparison with those reported for other established total knee systems. Caution is advised when using this implant, particularly for less experienced knee surgeons.
Resumo:
INTRODUCTION Cardiac myocytes utilize three high-capacity Na transport processes whose precise function can determine myocyte fate and the triggering of arrhythmias in pathological settings. We present recent results on the regulation of all three transporters that may be important for an understanding of cardiac function during ischemia/reperfusion episodes. METHODS AND RESULTS Refined ion selective electrode (ISE) techniques and giant patch methods were used to analyze the function of cardiac Na/K pumps, Na/Ca exchange (NCX1), and Na/H exchange (NHE1) in excised cardiac patches and intact myocytes. To consider results cohesively, simulations were developed that account for electroneutrality of the cytoplasm, ion homeostasis, water homeostasis (i.e., cell volume), and cytoplasmic pH. The Na/K pump determines the average life-time of Na ions (3-10 minutes) as well as K ions (>30 minutes) in the cytoplasm. The long time course of K homeostasis can determine the time course of myocyte volume changes after ion homeostasis is perturbed. In excised patches, cardiac Na/K pumps turn on slowly (-30 seconds) with millimolar ATP dependence, when activated for the first time. In steady state, however, pumps are fully active with <0.2 mM ATP and are nearly unaffected by high ADP (2 mM) and Pi (10 mM) concentrations as may occur in ischemia. NCX1s appear to operate with slippage that contributes to background Na influx and inward current in heart. Thus, myocyte Na levels may be regulated by the inactivation reactions of the exchanger which are both Na- and proton-dependent. NHE1 also undergo strong Na-dependent inactivation, whereby a brief rise of cytoplasmic Na can cause inactivation that persists for many minutes after cytoplasmic Na is removed. This mechanism is blocked by pertussis toxin, suggesting involvement of a Na-dependent G-protein. Given that maximal NCX1- and NHE1-mediated ion fluxes are much greater than maximal Na/K pump-mediated Na extrusion in myocytes, the Na-dependent inactivation mechanisms of NCX1 and NHE1 may be important determinants of cardiac Na homeostasis. CONCLUSIONS Na/K pumps appear to be optimized to continue operation when energy reserves are compromised. Both NCX1 and NHE1 activities are regulated by accumulation of cytoplasmic Na. These principles may importantly control cardiac cytoplasmic Na and promote myocyte survival during ischemia/reperfusion episodes by preventing Ca overload.
Resumo:
PURPOSE The implementation of genomic-based medicine is hindered by unresolved questions regarding data privacy and delivery of interpreted results to health-care practitioners. We used DNA-based prediction of HIV-related outcomes as a model to explore critical issues in clinical genomics. METHODS We genotyped 4,149 markers in HIV-positive individuals. Variants allowed for prediction of 17 traits relevant to HIV medical care, inference of patient ancestry, and imputation of human leukocyte antigen (HLA) types. Genetic data were processed under a privacy-preserving framework using homomorphic encryption, and clinical reports describing potentially actionable results were delivered to health-care providers. RESULTS A total of 230 patients were included in the study. We demonstrated the feasibility of encrypting a large number of genetic markers, inferring patient ancestry, computing monogenic and polygenic trait risks, and reporting results under privacy-preserving conditions. The average execution time of a multimarker test on encrypted data was 865 ms on a standard computer. The proportion of tests returning potentially actionable genetic results ranged from 0 to 54%. CONCLUSIONS The model of implementation presented herein informs on strategies to deliver genomic test results for clinical care. Data encryption to ensure privacy helps to build patient trust, a key requirement on the road to genomic-based medicine.Genet Med advance online publication 14 January 2016Genetics in Medicine (2016); doi:10.1038/gim.2015.167.
Resumo:
Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.