6 resultados para Audiometry.

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although non-organic hearing losses are relatively rare, it is important to identify suspicious findings early to be able to administer specific tests, such as objective measurements and specific counseling. In this retrospective study, we searched for findings that were specific ti or typical for non-organic hearing losses. Patient records from a 6 year period (2003-2008) from the University ENT Department of Bern, Switzerland, were reviewed. In this period, 40 subjects were diagnosed with a non-organic hearing loss (22 children, ages 7-16, mean 10.6 years; 18 adults, ages 19-57, mean 39.7 years; 25 females and 15 males). Pure tone audiograms in children and adults showed predominantly sensorineural and frequency-independent hearing losses, mostly in the range of 40-60 dB. In all cases, objective measurements (otoacoustic emissions and/or auditory-evoked potentials) indicated normal or substantially better hearing thresholds than those found in pure tone audiometry. In nine subjects (22.5%; 2 children, 7 adults), hearing aids had been fitted before the first presentation at our center. Six children (27%) had a history of middle ear problems with a transient hearing loss and 11 (50%) knew a person with a hearing loss. Two new and hitherto unreported findings emerged from the analysis: it was observed that a small air-bone gap of 5-20 dB was typical for non-organic hearing losses and that speech audiometry might show considerably poorer results than expected from pure tone audiometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We sought to evaluate the relative value of pure tone audiometry (PTA), extended high-frequency audiometry (EFA) and transiently evoked otoacoustic emissions (OAE) and distortion products when monitoring acute acoustic trauma (AAT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A set of algorithms, which allows a computer to determine the answers of simulated patients during pure tone and speech audiometry, is presented. Based on these algorithms, a computer program for training in audiometry was written and found to be useful for teaching purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacterial meningitis is characterized by an inflammatory reaction to the invading pathogens that can ultimately lead to sensorineural hearing loss, permanent brain injury, or death. The matrix metalloproteinases (MMPs) and tumor necrosis factor alpha-converting enzyme (TACE) are key mediators that promote inflammation, blood-brain barrier disruption, and brain injury in bacterial meningitis. Doxycycline is a clinically used antibiotic with anti-inflammatory effects that lead to reduced cytokine release and the inhibition of MMPs. Here, doxycycline inhibited TACE with a 50% inhibitory dose of 74 microM in vitro and reduced the amount of tumor necrosis factor alpha released into the cerebrospinal fluid by 90% in vivo. In an infant rat model of pneumococcal meningitis, a single dose of doxycycline (30 mg/kg) given as adjuvant therapy in addition to ceftriaxone 18 h after infection significantly reduced the mortality, the blood-brain barrier disruption, and the extent of cortical brain injury. Adjuvant doxycycline (30 mg/kg given subcutaneously once daily for 4 days) also attenuated hearing loss, as assessed by auditory brainstem response audiometry, and neuronal death in the cochlear spiral ganglion at 3 weeks after infection. Thus, doxycycline, probably as a result of its anti-inflammatory properties, had broad beneficial effects in the brain and the cochlea and improved survival in this model of pneumococcal meningitis in infant rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The primary purpose of the clinical trial was to assess the safety and efficacy of once-a-day compared with three-times-a-day gentamicin in patients with serious infections who had protocol-determined peak serum aminoglycoside concentrations. PATIENTS AND METHODS: A total of 249 hospitalized patients with suspected or proven serious infections were randomized in a 2:2:1 ratio to gentamicin given three times a day with ticarcillin-clavulanate (TC), gentamicin once a day with TC, or ticarcillin-clavulanate (TC) alone. The gentamicin once-a-day dosage for patients with estimated creatinine clearance values of > or =80 mL/min was 5.1 mg/kg. With lower creatinine clearance estimates, the mg/kg dosage of gentamicin was decreased, and the dosage intervals (once daily or three times a day) were maintained. Evaluability required documentation of achievement of protocol-defined peak serum gentamicin levels. RESULTS: Of the total 175 evaluable patients, there were no significant differences found between treatment regimens with respect to clinical or microbiologic efficacy. Bedside audiometry proved impractical due to the frequency of altered mental state in ill patients. Based on the traditional increase in serum creatinine values from baseline values, no differences in renal toxicity between the treatment groups was identified. When changes in renal function were reanalyzed based on maintaining, as opposed to worsening, of renal function, preservation of renal function was better in the gentamicin once-a-day patients as opposed to the gentamicin three-times-a-day patients, P <0.01. CONCLUSIONS: Gentamicin once a day plus TC, gentamicin three times a day plus TC, and TC alone had similar effects in seriously ill hospitalized patients. The incidence of nephrotoxicity was similar in the three treatment groups. Using a nonvalidated post-hoc analysis, renal function was better preserved in gentamicin once-a-day + TC and TC-only patients as opposed to gentamicin three-times-a-day + TC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN Prospective multicenter study. SETTING The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTION Implantation with a Codacs direct acoustic cochlear implant investigational device (ID) combined with a stapedotomy with a conventional stapes prosthesis MAIN OUTCOME MEASURES Preoperative and postoperative (3 months after activation of the investigational direct acoustic cochlear implant) audiometric evaluation measuring conventional pure tone and speech audiometry, tympanometry, aided thresholds in sound field and hearing difficulty by the Abbreviated Profile of Hearing Aid Benefit questionnaire. RESULTS The preoperative and postoperative air and bone conduction thresholds did not change significantly by the implantation with the investigational Direct Acoustic Cochlear Implant. The mean sound field thresholds (0.25-8 kHz) improved significantly by 48 dB. The word recognition scores (WRS) at 50, 65, and 80 dB SPL improved significantly by 30.4%, 75%, and 78.2%, respectively, after implantation with the investigational direct acoustic cochlear implant compared with the preoperative unaided condition. The difficulty in hearing, measured by the Abbreviated Profile of Hearing Aid Benefit, decreased by 27% after implantation with the investigational direct acoustic cochlear implant. CONCLUSION Patients with moderate-to-severe mixed hearing loss because of otosclerosis can benefit substantially using the Codacs investigational device.