There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9 x 9 cm with a resolution of 256 x 256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early detection is a major goal in the management of malignant melanoma. Besides clinical assessment many noninvasive technologies such as dermoscopy, digital dermoscopy and in vivo laser scanner microscopy are used as additional methods. Herein we tested a system to assess lesional perfusion as a tool for early melanoma detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess influence of durotomy on spinal cord blood flow (SCBF) in chondrodystrophic dogs with thoracolumbar disk extrusion. STUDY DESIGN: Prospective cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n = 11). METHODS: Diagnosis was based on neurologic signs, magnetic resonance imaging (MRI) findings, and surgical confirmation. Regional SCBF was measured 3 times intraoperatively by laser-Doppler flowmetry: (1) before surgical decompression; (2) immediately after decompression by hemilaminectomy-durotomy; and (3) after 15 minutes of lesion lavage. A standardized hemilaminectomy and durotomy performed by the same neurosurgeon, was used to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found immediately after spinal cord decompression and durotomy in dogs but SCBF returned to previous levels or lower after 15 minutes of lavage. Changes in SCBF were not associated with duration of clinical signs; neurologic status, degree of spinal cord compression, or signal intensity changes as assessed by MRI. CONCLUSION: Durotomy does not increase SCBF in dogs with disk extrusion associated spinal cord compression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thiel-embalmed human whole head specimens represent an alternative model in middle ear research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the pulp sensitivity and vitality of mandibular incisors and canines before and after bone harvesting in the symphysis. MATERIALS AND METHODS: In 20 patients requiring bone grafts from the symphysis, pulp sensitivity (carbon dioxide [CO2]) and pulpal blood flow (laser Doppler flowmetry [LDF]) of mandibular incisors and canines were evaluated preoperatively, postoperatively, and 6 months after surgery. Teeth were allocated to 1 of 3 groups according to their initial and final reaction to CO2 (group A = teeth with a positive reaction throughout the study, group B = teeth that exhibited a sensitivity change from positive to negative, and group C = teeth with a negative reaction throughout the study). RESULTS: Preoperative flux measurements (LDF) did not differ between groups A, B, and C. Teeth with sensitivity changes (group B) showed the greatest decrease (a statistically significant decrease) of pulpal blood flow over time, whereas teeth in groups A and C demonstrated an insignificant reduction of flux over time. DISCUSSION AND CONCLUSIONS: LDF was purely used as an experimental tool in the present study. Pulpal blood flow measurements using LDF demonstrated a decrease of flux over time in anterior mandibular teeth following bone harvesting in the symphysis. A significant change of flux, however, was only observed for teeth that also demonstrated a loss of pulp sensitivity during the same study period. Loss of pulp sensitivity appeared to be correlated to a significant decrease of blood flow assessed by LDF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The identification and accurate location of centers of brain activity are vital both in neuro-surgery and brain research. This study aimed to provide a non-invasive, non-contact, accurate, rapid and user-friendly means of producing functional images intraoperatively. To this end a full field Laser Doppler imager was developed and integrated within the surgical microscope and perfusion images of the cortical surface were acquired during awake surgery whilst the patient performed a predetermined task. The regions of brain activity showed a clear signal (10-20% with respect to the baseline) related to the stimulation protocol which lead to intraoperative functional brain maps of strong statistical significance and which correlate well with the preoperative fMRI and intraoperative cortical electro-stimulation. These initial results achieved with a prototype device and wavelet based regressor analysis (the hemodynamic response function being derived from MRI applications) demonstrate the feasibility of LDI as an appropriate technique for intraoperative functional brain imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: (1) To assess spinal cord blood flow (SCBF) during surgical treatment of disk extrusion in dogs and (2) to investigate associations between SCBF, clinical signs, presurgical MRI images, and 24-hour surgical outcome. STUDY DESIGN: Cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n=12). METHODS: Diagnosis was based on clinical signs and MRI findings, and confirmed at surgery. Regional SCBF was measured intraoperatively by laser-Doppler flowmetry before, immediately after surgical spinal cord decompression, and after 15 minutes of lavaging the lesion. Care was taken to ensure a standardized surgical procedure to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found in all dogs (Wilcoxon's signed-rank test; P=.05) immediately after spinal cord decompression and after 15 minutes. Changes in SCBF were not associated with duration of clinical signs; initial or 24-hour neurologic status; or degree of spinal cord compression assessed by MRI. CONCLUSION: SCBF increases immediately after spinal cord decompression in dogs with disk herniation; however, increased SCBF was not associated with a diminished 24-hour neurologic status. CLINICAL RELEVANCE: An increase in SCBF does not appear to be either associated with the degree of spinal cord compression or of a magnitude sufficient to outweigh the benefit of surgical decompression by resulting in clinically relevant changes in 24-hour outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. METHODS A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. RESULTS In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. CONCLUSION The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Despite different existing methods, monitoring of free muscle transfer is still challenging. In the current study we evaluated our clinical setting regarding monitoring of such tissues, using a recent microcirculation-imaging camera (EasyLDI) as an additional tool for detection of perfusion incompetency. PATIENTS AND METHODS This study was performed on seven patients with soft tissue defect, who underwent reconstruction with free gracilis muscle. Beside standard monitoring protocol (clinical assessment, temperature strips, and surface Doppler), hourly EasyLDI monitoring was performed for 48 hours. Thereby a baseline value (raised flap but connected to its vascular bundle) and an ischaemia perfusion value (completely resected flap) were measured at the same point. RESULTS The mean age of the patients, mean baseline value, ischaemia value perfusion were 48.00 ± 13.42 years, 49.31 ± 17.33 arbitrary perfusion units (APU), 9.87 ± 4.22 APU, respectively. The LDI measured values in six free muscle transfers were compatible with hourly standard monitoring protocol, and normalized LDI values significantly increased during time (P < 0.001, r = 0.412). One of the flaps required a return to theatre 17 hours after the operation, where an unsalvageable flap loss was detected. All normalized LDI values of this flap were under the ischaemia perfusion level and the trend was significantly descending during time (P < 0.001, r = -0.870). CONCLUSION Due to the capability of early detection of perfusion incompetency, LDI may be recommended as an additional post-operative monitoring device for free muscle flaps, for early detection of suspected failing flaps and for validation of other methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Port-wine stains (PWS) are malformations of capillaries in 0.3% of newborn children. The treatment of choice is by pulsed dye LASER (PDL), and requires several sessions. The efficacy of this treatment is at present evaluated on the basis of clinical inspection and of digital photographs taken throughout the treatment. LASER-Doppler imaging (LDI) is a noninvasive method of imaging the perfusion of the tissues by the microcirculatory system (capillaries). The aim of this paper is to demonstrate that LDI allows a quantitative, numerical evaluation of the efficacy of the PDL treatment of PWS. METHOD The PDL sessions were organized according to the usual scheme, every other month, from September 1, 2012, to September 30, 2013. LDI imaging was performed at the start and at the conclusion of the PDL treatment, and simultaneously on healthy skin in order to obtain reference values. The results evidenced by LDI were analyzed according to the "Wilcoxon signed-rank" test before and after each session, and in the intervals between the three PDL treatment sessions. RESULTS Our prospective study is based on 20 new children. On average, the vascularization of the PWS was reduced by 56% after three laser sessions. Compared with healthy skin, initial vascularization of PWS was 62% higher than that of healthy skin at the start of treatment, and 6% higher after three sessions. During the 2 months between two sessions, vascularization of the capillary network increased by 27%. CONCLUSION This study shows that LDI can demonstrate and measure the efficacy of PDL treatment of PWS in children. The figures obtained when measuring the results by LDI corroborate the clinical assessments and may allow us to refine, and perhaps even modify, our present use of PDL and thus improve the efficacy of the treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The round window placement of a floating mass transducer (FMT) is a new approach for coupling an implantable hearing system to the cochlea. We evaluated the vibration transfer to the cochlear fluids of an FMT placed at the round window (rwFMT) with special attention to the role of bone conduction. A posterior tympanotomy was performed on eleven ears of seven human whole head specimens. Several rwFMT setups were examined using laser Doppler vibrometry measurements at the stapes and the promontory. In three ears, the vibrations of a bone anchored hearing aid (BAHA) and an FMT fixed to the promontory (pFMT) were compared to explore the role of bone conduction. Vibration transmission to the measuring point at the stapes was best when the rwFMT was perpendicularly placed in the round window and underlayed with connective tissue. Fixation of the rwFMT to the round window exhibited significantly lower vibration transmission. Although measurable, bone conduction from the pFMT was much lower than that of the BAHA. Our results suggest that the rwFMT does not act as a small bone anchored hearing aid, but instead, acts as a direct vibratory stimulator of the round window membrane.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. MATERIALS AND METHODS: Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after preparation, baseline measurements were taken. At first, 5% of total blood volume was withdrawn, followed by another 5% increment, and then in 10% increments until death. RESULTS: After withdrawal of 5% of estimated blood volume, dPP increased from 6.1% +/- 3.0% to 20.8% +/- 2.7% (P < 0.01). Mean arterial pressure (MAP), mean pulmonary artery pressure (PAP) and pulmonary artery occlusion pressure (PAOP) decreased with a blood loss of 10% (P < 0.01). Cardiac output (CO) changed after a blood loss of 20% (P < 0.05). Tissue oxygen tension in central organs, and blood flow in the jejunal muscularis decreased (P < 0.05) after a blood loss of 20%. Tissue oxygen tension in the skin, and jejunal mucosa blood flow decreased (P < 0.05) after a blood loss of 40% and 50%, respectively. CONCLUSIONS: In this hemorrhagic pig model systemic hemodynamic parameters were more sensitive to detect acute hypovolemia than tissue oxygen tension measurements or jejunal LDF measurements. Acute blood loss was detected first by dPP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Sepsis may impair mitochondrial utilization of oxygen. Since hepatic dysfunction is a hallmark of sepsis, we hypothesized that the liver is more susceptible to mitochondrial dysfunction than the peripheral tissues, such as the skeletal muscle. We studied the effect of prolonged endotoxin infusion on liver, muscle and kidney mitochondrial respiration and on hepatosplanchnic oxygen transport and microcirculation in pigs. METHODS: 20 anesthetized pigs were randomized to receive endotoxin or saline infusion for 24 hours. Muscle, liver and kidney mitochondrial respiration was assessed. Cardiac output (thermodilution), carotid, superior mesenteric and kidney arterial, portal venous (ultrasound Doppler) and microcirculatory blood flow (laser Doppler) were measured, and systemic and regional oxygen transport and lactate exchange were calculated. RESULTS: Endotoxin infusion induced hyperdynamic shock and impaired the glutamate- and succinate-dependent mitochondrial respiratory control ratio (RCR) in the liver (glutamate: endotoxemia: median [range] 2.8 [2.3-3.8] vs. controls: 5.3 [3.8-7.0]; p<0.001; succinate: endotoxemia: 2.9 [1.9-4.3] vs. controls: 3.9 [2.6-6.3] p=0.003). While the ADP:O ratio was reduced with both substrates, maximal ATP production was impaired only in the succinate-dependent respiration. Hepatic oxygen consumption and extraction, and liver surface laser Doppler blood flow remained unchanged. Glutamate-dependent respiration in the muscle and kidney was unaffected. CONCLUSIONS: Endotoxemia reduces the efficiency of hepatic but neither skeletal muscle nor kidney mitochondrial respiration, independent of regional and microcirculatory blood flow changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To test the hypothesis that endovascular revascularization of femoropopliteal lesions improves the impaired venoarteriolar response (VAR) in patients with atherosclerosis. METHODS: We prospectively compared VARs in 15 healthy controls (18 legs) and 14 patients (17 legs) with mild to moderate peripheral arterial disease before and after successful peripheral endovascular angioplasty of femoropopliteal lesions. In all subjects, foot skin blood flow was assessed by laser Doppler flowmetry in the horizontal (HBF) and sitting (SBF) positions. VAR was calculated as (HBF - SBF)/HBF x 100. RESULTS: In patients with peripheral arterial disease, mean HBF (in arbitrary units [AU]; mean +/- SD) was similar before (25.6 +/- 15.3 AU) and after (27.0 +/- 16.4 AU) angioplasty (P = .67), whereas SBF was significantly lower after than before the endovascular procedure (11.6 +/- 7.7 AU to 18.4 +/- 14.1 AU; P < .05). Intragroup differences between SBF and HBF were significant before and after angioplasty (P < .001). VAR was higher after angioplasty (55.1% +/- 21.2%) compared with VAR before intervention (33.4% +/- 20.2%; P = .015). Although VAR increased after the intervention, VAR was still lower than in healthy controls (68.4% +/- 20.5%; P = .025). During the 6 months of follow-up, the ankle-brachial index and VAR remained unchanged (P > .05). CONCLUSIONS: Patients with mild to moderate peripheral arterial disease have an impaired orthostatic autoregulation that improves after successful endovascular revascularization of femoropopliteal obstructive lesions. The effect on VAR is sustained in the absence of restenosis.