Resumo:
We report a case involving a spring-gun device (muzzleloader) loaded solely with gunpowder, installed next to shoes to prevent the neighbors' puppy from removing them. The booby trap was triggered by the 15-year-old dog-owners son when he tried to put the shoes out of the reach of the puppy. The boy suffered second degree superficial burns located mainly at the dorsal side of the right hand and fingers. To estimate the danger of the used weapon, several tests were undertaken on soap blocks from different distances and with different loads of black powder. The particle density per mm and the depth of black powder tattooing in the soap was compared with the boy's injuries, and found conclusive with the gun-owners statement regarding the loading of the weapon. Furthermore, our experiments indicated that the gunpowder load involved was not able to inflict permanent damage, not even to the eyes, at the here estimated firing distance.
Resumo:
We assessed the diagnostic accuracy and time effectiveness of the Statscan low-dose full-body digital x-ray machine in the evaluation of ventriculoperitoneal (VP) shunt dysfunction.
Resumo:
The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.
Resumo:
To evaluate the safety of a new ultravitrification closed device.
Evaluation of perpendicular reflection intensity for assessment of caries lesion activity/inactivity
Resumo:
The aim of this study was to evaluate, using visual assessment, an experimental optical sensor measuring perpendicular reflection intensity (PRI) as an indicator of enamel caries lesion activity/inactivity. Forty teeth with either an active or an inactive enamel lesion were selected from a pool of extracted teeth. Each tooth was cut into halves, with a clinically sound half and a half with a non-cavitated enamel lesion. After gentle plaque removal, the teeth were kept moistened. The lesions were then photographed and a defined measuring site per lesion was chosen and indicated with an arrow on a printout. Independently, the chosen site was visually assessed for lesion activity, and its glossiness was measured with PRI assessment. Surface roughness (SR) was assessed with optical profilometry using a confocal microscope. Visual assessment and PRI were repeated after several weeks and a reliability analysis was performed. For enamel lesions visually scored as active versus inactive, significantly different values were obtained with both PRI and SR. PRI values of the clinically sound control surfaces were significantly different only from active lesions. Generally, inactive lesions had the same glossiness and the same roughness as the sound control surfaces. The reliabilities for visual assessment (? = 0.89) and for PRI (ICC = 0.86) were high. It is concluded that, within the limits of this study, PRI can be regarded as a promising tool for quantitative enamel lesion activity assessment. There is scope and potential for the PRI device to be considerably improved for in vivo use.
Resumo:
STUDY DESIGN:: retrospective analysis of prospectively collected clinical data. OBJECTIVE:: To assess the long-term outcome of patients with monosegmental L4/5 degenerative spondylolisthesis treated with the dynamic Dynesys device. SUMMARY OF BACKGROUND DATA:: The Dynesys® system has been used as a semirigid, lumbar dorsal pedicular stabilization device since 1994. Good short-term results have been reported, but little is known about the long-term outcome following treatment for degenerative spondylolisthesis at the L4/5 level. METHODS:: 39 consecutive patients with symptomatic degenerative lumbar spondylolisthesis at the L4/5 level were treated with bilateral decompression and Dynesys instrumentation. At a mean follow-up of 7.2 years (range 5.0-11.2▒y) they underwent clinical and radiographic evaluation and quality of life assessment. RESULTS:: At final follow-up back pain improved in 89% and leg pain improved in 86% of patients compared to preoperative status. 83% of patients reported global subjective improvement. 92% would undergo the surgery again. 8 patients (21%) required further surgery due to symptomatic adjacent segment disease (6 cases), late onset infection (1 case), and screw breakage (1 case). In 9 cases radiological progression of spondylolisthesis at the operated segment was found. 74% of operated segments showed limited flexion-extension range of less than 4°. Adjacent segment pathology, though without clinical correlation, was diagnosed at the L5/S1 (17.9%) and L3/4 (28.2%) segments. In 4 cases asymptomatic screw loosening was observed. CONCLUSION:: Monosegmental Dynesys instrumentation of degenerative spondylolisthesis at L4/5 shows good long-term results. The rate of secondary surgeries is comparable to other dorsal instrumentation devices. Residual range of motion in the stabilized segment is reduced, and the rate of radiological and symptomatic adjacent segment degeneration is low. Patient satisfaction is high. Dynesys stabilization of symptomatic L4/5 degenerative spondylolisthesis is a possible alternative to other stabilization devices.
Resumo:
Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint loading apparatus allowing unconstrained knee motion as well as compression and varus-valgus loading. Four different experiments were performed on each specimen. (1) Knee joints were axially loaded. Comparison between applied and measured compressive forces demonstrated the accuracy and reliability of in situ measurements (1.8N). (2) Assessment of knee stability based on condyle contact forces or varus-valgus moments were compared to the current surgical method (difference of varus-valgus loads causing condyle lift-off). The force-based approach was equivalent to the surgical method while the moment-based, which is considered optimal, showed a tendency of lateral imbalance. (3) To estimate the importance of keeping the patella in its anatomical position during imbalance assessment, the effect of patellar eversion on the mediolateral distribution of tibiofemoral contact forces was measured. One fourth of the contact force induced by the patellar load was shifted to the lateral compartment. (4) The effect of minor and major medial collateral ligament releases was biomechanically quantified. On average, the medial contact force was reduced by 20% and 46%, respectively. Large variation among specimens reflected the difficulty of ligament release and the need for intraoperative force monitoring. This series of experiments thus demonstrated the device's potential to improve ligament balancing and survivorship of total knee arthroplasty.
Resumo:
A prerequisite for preventive measures is to diagnose erosive tooth wear and to evaluate the different etiological factors in order to identify persons at risk. No diagnostic device is available for the assessment of erosive defects. Thus, they can only be detected clinically. Consequently, erosion not diagnosed in the early stage may render timely preventive measures difficult. In order to assess the risk factors, patient should record their dietary intake for a distinct period of time. Then a dentist can determine the erosive potential of the diet. Particularly, patients with more than four dietary acid intakes have a higher risk for erosion when other risk factors (such as holding the drink in the mouth) are present. Regurgitation of gastric acids (reflux, vomiting, alcohol abuse, etc.) is a further important risk factor for the development of erosion which has to be taken into account. Based on these analyses, an individually tailored preventive program may be suggested to the patients. It may comprise dietary advice, optimization of fluoride regimes, stimulation of salivary flow rate, use of buffering medicaments and particular motivation for nondestructive toothbrushing habits with a low abrasive toothpaste. The frequent use of fluoride gel and fluoride solution in addition to fluoride toothpaste offers the opportunity to reduce somewhat abrasion of tooth substance. It is also advisable to avoid abrasive tooth cleaning and whitening products, since they may remove the pellicle and may render teeth more susceptible to erosion. Since erosion, attrition and abrasion often occur simultaneously all causative components must be taken into consideration when planning preventive strategies.
Resumo:
AIM: We sought to investigate the prevalence of posttraumatic stress disorder, anxiety, and depression in patients and their partners after implantation of a mechanical assist device as a bridge to heart transplantation. METHODS: This was a retrospective assessment of 41 patients (age 46.3 +/- 12.0 years; male-female ratio, 38:3; time since transplantation, 55.3 +/- 34.2 months [range, 7-122 months) and 27 partners (male-female ratio 2:25) by standardized instruments (Impact of Event Scale, Hospital Anxiety and Depression Scale), in 2 University Heart Transplant Centers (Vienna, Austria, Munster, Germany). The duration of the support systems (MicroMed DeBakey-VAD in 17 patients, Novacor in 10, Thoratec in 8, TCI HeartMate in 5, and Berlin Heart Incor in 1 patient) ranged from 28 to 711 (176 +/- 146) days. RESULTS: None of the patients, but 23% of the partners (n = 6), met the criteria for posttraumatic stress disorder (Maercker cutoff >0). The Impact of Event Scale (IES) sum scales differed significantly between the 2 groups (21.2 +/- 15.1, mean +/- SD) for the patients versus 38.1 +/- 27.8 for the partners, respectively; P = .001). Two percent of the patients, but 19% of the partners, showed mild to moderate depression; 4% of patients, but 23% of their partners, reported mild to moderate anxiety. None of the results were significantly influenced by the time since transplantation, patient age, diagnoses, type of assist device, or indication for heart transplantation. CONCLUSIONS: Despite patients being much closer to a life threat, their partners experience significantly more psychologic distress even in the long run. Our findings highlight the need for attention to the supporting persons.
Resumo:
PURPOSE: Two noninvasive methods to measure dental implant stability are damping capacity assessment (Periotest) and resonance frequency analysis (Osstell). The objective of the present study was to assess the correlation of these 2 techniques in clinical use. MATERIALS AND METHODS: Implant stability of 213 clinically stable loaded and unloaded 1-stage implants in 65 patients was measured in triplicate by means of resonance frequency analysis and Periotest. Descriptive statistics as well as Pearson's, Spearman's, and intraclass correlation coefficients were calculated with SPSS 11.0.2. RESULTS: The mean values were 57.66 +/- 8.19 implant stability quotient for the resonance frequency analysis and -5.08 +/- 2.02 for the Periotest. The correlation of both measuring techniques was -0.64 (Pearson) and -0.65 (Spearman). The single-measure intraclass correlation coefficients for the ISQ and Periotest values were 0.99 and 0.88, respectively (95% CI). No significant correlation of implant length with either resonance frequency analysis or Periotest could be found. However, a significant correlation of implant diameter with both techniques was found (P < .005). The correlation of both measuring systems is moderate to good. It seems that the Periotest is more susceptible to clinical measurement variables than the Osstell device. The intraclass correlation indicated lower measurement precision for the Periotest technique. Additionally, the Periotest values differed more from the normal (Gaussian) curve of distribution than the ISQs. Both measurement techniques show a significant correlation to the implant diameter. CONCLUSION: Resonance frequency analysis appeared to be the more precise technique.
Resumo:
OBJECTIVES: To determine the clinical performance of a laser fluorescence device (DIAGNOdent pen, KaVo) to discriminate between different occlusal caries depths (D(0)-D(1-4); D(0-2)-D(3,4)) in permanent molars. METHODS: In this prospective, randomized two-centre-study 120 sound/uncavitated carious sites in 120 patients were measured after visual and radiographic caries assessment. In cases of operative intervention (n=86), the lesion depths after caries removal were recorded (reference). In cases of preventive intervention (n=34), the sites were reassessed visually/radiographically after 12 months to verify the status assessed before (reference). The discrimination performance was determined statistically (Mann-Whitney test, Spearman's rho coefficient, and areas under the receiver operating characteristic curves (AUCs)). Sensitivities (SE) and specificities (SP) were plotted as a function of the measured values and cut-off values for the mentioned thresholds suggested. RESULTS: Sound sites (n=13) had significantly minor fluorescence values than carious sites (n=107) (P<0.0001) as had sites with no/enamel caries (n=63) compared to dentinal caries (n=57). The AUCs for the same discriminations were 0.92 and 0.78 (P<0.001). For the D(0)-D(1-4) threshold, a cut-off at a value of 12 (SE: 0.88, SP: 0.85) and for the D(0-2)-D(3,4) threshold at 25 (SE: 0.67, SP: 0.79) can be suggested. A moderate positive correlation between the measurements and the caries depths was calculated (rho=+0.57, P=0.01). CONCLUSION: Within this study, the device's discrimination performance for different caries depths was moderate to very good and it may be recommended as adjunct tool in the diagnosis of occlusal caries.
Resumo:
BACKGROUND: Several clinical studies on chronic stroke conducted with end-effector-based robots showed improvement of the motor function in the affected arm. Compared to end-effector-based robots, exoskeleton robots provide improved guidance of the human limb and are better suited to train task-oriented movements with a large range of motions. OBJECTIVE: To test whether intensive arm training with the arm exoskeleton ARMin I is feasible with chronic-stroke patients and whether it improves motor function in the paretic arm. METHODS: Three single cases with chronic hemiparesis resulting from unilateral stroke (at least 14 months after stroke). A-B design with 2 weeks of multiple baseline measurements (A), 8 weeks of training (B) with repetitive measurements and a follow-up measurement 8 weeks after training. The training included shoulder and elbow movements with the robotic rehabilitation device ARMin I. Two subjects had three 1-hour sessions per week and 1 subject received five 1-hour sessions per week. The main outcome measurement was the upper-limb part of the Fugl-Meyer Assessment (FMA). RESULTS: The ARMin training was well tolerated by the patients, and the FMA showed moderate, but significant improvements for all 3 subjects (p < 0.05). Most improvements were maintained 8 weeks after discharge. CONCLUSIONS: This study indicates that intensive training with an arm exoskeleton is feasible with chronic-stroke patients. Moderate improvements were found in all 3 subjects, thus further clinical investigations are justified.
Resumo:
BACKGROUND:
Robotics-assisted tilt table technology was introduced for early rehabilitation of neurological patients. It provides cyclical stepping movement and physiological loading of the legs. The aim of the present study was to assess the feasibility of this type of device for peak cardiopulmonary performance testing using able-bodied subjects.
METHODS:
A robotics-assisted tilt table was augmented with force sensors in the thigh cuffs and a work rate estimation algorithm. A custom visual feedback system was employed to guide the subjects' work rate and to provide real time feedback of actual work rate. Feasibility assessment focused on: (i) implementation (technical feasibility), and (ii) responsiveness (was there a measurable, high-level cardiopulmonary reaction?). For responsiveness testing, each subject carried out an incremental exercise test to the limit of functional capacity with a work rate increment of 5 W/min in female subjects and 8 W/min in males.
RESULTS:
11 able-bodied subjects were included (9 male, 2 female; age 29.6 ± 7.1 years: mean ± SD). Resting oxygen uptake (O
Resumo:
A prerequisite for preventive measures is to diagnose erosive tooth wear and to evaluate the different etiological factors in order to identify persons at risk. No diagnostic device is available for the assessment of erosive defects. Thus, they can only be detected clinically. Consequently, erosion not diagnosed at an early stage may render timely preventive measures difficult. In order to assess the risk factors, patients should record their dietary intake for a distinct period of time. Then a dentist can determine the erosive potential of the diet. A table with common beverages and foodstuffs is presented for judging the erosive potential. Particularly, patients with more than 4 dietary acid intakes have a higher risk for erosion when other risk factors are present. Regurgitation of gastric acids is a further important risk factor for the development of erosion which has to be taken into account. Based on these analyses, an individually tailored preventive program may be suggested to the patients. It may comprise dietary advice, use of calcium-enriched beverages, optimization of prophylactic regimes, stimulation of salivary flow rate, use of buffering medicaments and particular motivation for nondestructive toothbrushing habits with an erosive-protecting toothpaste as well as rinsing solutions. Since erosion and abrasion often occur simultaneously, all of the causative components must be taken into consideration when planning preventive strategies but only those important and feasible for an individual should be communicated to the patient.
Resumo:
OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).