14 resultados para Arvo Pärt
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Identifying a human body stimulus involves mentally rotating an embodied spatial representation of one's body (motoric embodiment) and projecting it onto the stimulus (spatial embodiment). Interactions between these two processes (spatial and motoric embodiment) may thus reveal cues about the underlying reference frames. The allocentric visual reference frame, and hence the perceived orientation of the body relative to gravity, was modulated using the York Tumbling Room, a fully furnished cubic room with strong directional cues that can be rotated around a participant's roll axis. Sixteen participants were seated upright (relative to gravity) in the Tumbling Room and made judgments about body and hand stimuli that were presented in the frontal plane at orientations of 0°, 90°, 180° (upside down), or 270° relative to them. Body stimuli have an intrinsic visual polarity relative to the environment whereas hands do not. Simultaneously the room was oriented 0°, 90°, 180° (upside down), or 270° relative to gravity resulting in sixteen combinations of orientations. Body stimuli were more accurately identified when room and body stimuli were aligned. However, such congruency did not facilitate identifying hand stimuli. We conclude that static allocentric visual cues can affect embodiment and hence performance in an egocentric mental transformation task. Reaction times to identify either hands or bodies showed no dependence on room orientation.
Resumo:
Perceptual learning can occur when stimuli are only imagined, i.e., without proper stimulus presentation. For example, perceptual learning improved bisection discrimination when only the two outer lines of the bisection stimulus were presented and the central line had to be imagined. Performance improved also with other static stimuli. In non-learning imagery experiments, imagining static stimuli is different from imagining motion stimuli. We hypothesized that those differences also affect imagery perceptual learning. Here, we show that imagery training also improves motion direction discrimination. Learning occurs when no stimulus at all is presented during training, whereas no learning occurs when only noise is presented. The interference between noise and mental imagery possibly hinders learning. For static bisection stimuli, the pattern is just the opposite. Learning occurs when presented with the two outer lines of the bisection stimulus, i.e., with only a part of the visual stimulus, while no learning occurs when no stimulus at all is presented.
Resumo:
The preferred type of post-remission therapy (PRT) in patients with acute myeloid leukemia (AML) in first complete remission (CR1) is a subject of continued debate, especially in patients at higher risk of nonrelapse mortality (NRM), including patients >40 years of age. We report results of a time-dependent multivariable analysis of allogenic hematopoietic stem cell transplantation (alloHSCT) (n=337) versus chemotherapy (n=271) or autologous HSCT (autoHSCT) (n=152) in 760 patients aged 40-60 years with AML in CR1. Patients receiving alloHSCT showed improved overall survival (OS) as compared with chemotherapy (respectively, 57±3% vs 40±3% at 5 years, P<0.001). Comparable OS was observed following alloHSCT and autoHSCT in patients with intermediate-risk AML (60±4 vs 54±5%). However, alloHSCT was associated with less relapse (hazard ratio (HR) 0.51, P<0.001) and better relapse-free survival (RFS) (HR 0.74, P=0.029) as compared with autoHSCT in intermediate-risk AMLs. AlloHSCT was applied following myeloablative conditioning (n=157) or reduced intensity conditioning (n=180), resulting in less NRM, but comparable outcome with respect to OS, RFS and relapse. Collectively, these results show that alloHSCT is to be preferred over chemotherapy as PRT in patients with intermediate- and poor-risk AML aged 40-60 years, whereas autoHSCT remains a treatment option to be considered in patients with intermediate-risk AML.Leukemia advance online publication, 23 December 2014; doi:10.1038/leu.2014.332.
Resumo:
Perceived duration is assumed to be positively related to nontemporal stimulus magnitude. Most recently, the finding that larger stimuli are perceived to last longer has been challenged to represent a mere decisional bias induced by the use of comparative duration judgments. Therefore, in the present study, the method of temporal reproduction was applied as a psychophysical procedure to quantify perceived duration. Another major goal was to investigate the influence of attention on the effect of visual stimulus size on perceived duration. For this purpose, an additional dual-task paradigm was employed. Our results not only converged with previous findings in demonstrating a functional positive relationship between nontemporal stimulus size and perceived duration, but also showed that the effect of stimulus size on perceived duration was not confined to comparative duration judgments. Furthermore, the effect of stimulus size proved to be independent of attentional resources allocated to stimulus size; nontemporal visual stimulus information does not need to be processed intentionally to influence perceived duration. Finally, the effect of nontemporal stimulus size on perceived duration was effectively modulated by the duration of the target intervals, suggesting a hitherto largely unrecognized role of temporal context for the effect of nontemporal stimulus size to become evident.
Resumo:
New-onset impairment of ocular motility will cause incomitant strabismus, i.e., a gaze-dependent ocular misalignment. This ocular misalignment will cause retinal disparity, that is, a deviation of the spatial position of an image on the retina of both eyes, which is a trigger for a vergence eye movement that results in ocular realignment. If the vergence movement fails, the eyes remain misaligned, resulting in double vision. Adaptive processes to such incomitant vergence stimuli are poorly understood. In this study, we have investigated the physiological oculomotor response of saccadic and vergence eye movements in healthy individuals after shifting gaze from a viewing position without image disparity into a field of view with increased image disparity, thus in conditions mimicking incomitance. Repetitive saccadic eye movements into a visual field with increased stimulus disparity lead to a rapid modification of the oculomotor response: (a) Saccades showed immediate disconjugacy (p < 0.001) resulting in decreased retinal image disparity at the end of a saccade. (b) Vergence kinetics improved over time (p < 0.001). This modified oculomotor response enables a more prompt restoration of ocular alignment in new-onset incomitance.
Resumo:
Purpose Ophthalmologists are confronted with a set of different image modalities to diagnose eye tumors e.g., fundus photography, CT and MRI. However, these images are often complementary and represent pathologies differently. Some aspects of tumors can only be seen in a particular modality. A fusion of modalities would improve the contextual information for diagnosis. The presented work attempts to register color fundus photography with MRI volumes. This would complement the low resolution 3D information in the MRI with high resolution 2D fundus images. Methods MRI volumes were acquired from 12 infants under the age of 5 with unilateral retinoblastoma. The contrast-enhanced T1-FLAIR sequence was performed with an isotropic resolution of less than 0.5mm. Fundus images were acquired with a RetCam camera. For healthy eyes, two landmarks were used: the optic disk and the fovea. The eyes were detected and extracted from the MRI volume using a 3D adaption of the Fast Radial Symmetry Transform (FRST). The cropped volume was automatically segmented using the Split Bregman algorithm. The optic nerve was enhanced by a Frangi vessel filter. By intersection the nerve with the retina the optic disk was found. The fovea position was estimated by constraining the position with the angle between the optic and the visual axis as well as the distance from the optic disk. The optical axis was detected automatically by fitting a parable on to the lens surface. On the fundus, the optic disk and the fovea were detected by using the method of Budai et al. Finally, the image was projected on to the segmented surface using the lens position as the camera center. In tumor affected eyes, the manually segmented tumors were used instead of the optic disk and macula for the registration. Results In all of the 12 MRI volumes that were tested the 24 eyes were found correctly, including healthy and pathological cases. In healthy eyes the optic nerve head was found in all of the tested eyes with an error of 1.08 +/- 0.37mm. A successful registration can be seen in figure 1. Conclusions The presented method is a step toward automatic fusion of modalities in ophthalmology. The combination enhances the MRI volume with higher resolution from the color fundus on the retina. Tumor treatment planning is improved by avoiding critical structures and disease progression monitoring is made easier.
Resumo:
Purpose: Selective retina therapy (SRT) has shown great promise compared to conventional retinal laser photocoagulation as it avoids collateral damage and selectively targets the retinal pigment epithelium (RPE). Its use, however, is challenging in terms of therapy monitoring and dosage because an immediate tissue reaction is not biomicroscopically discernibel. To overcome these limitations, real-time optical coherence tomography (OCT) might be useful to monitor retinal tissue during laser application. We have thus evaluated a proprietary OCT system for its capability of mapping optical changes introduced by SRT in retinal tissue. Methods: Freshly enucleated porcine eyes, covered in DMEM upon collection were utilized and a total of 175 scans from ex-vivo porcine eyes were analyzed. The porcine eyes were used as an ex-vivo model and results compared to two time-resolved OCT scans, recorded from a patient undergoing SRT treatment (SRT Vario, Medical Laser Center Lübeck). In addition to OCT, fluorescin angiography and fundus photography were performed on the patient and OCT scans were subsequently investigated for optical tissue changes linked to laser application. Results: Biomicroscopically invisible SRT lesions were detectable in OCT by changes in the RPE / Bruch's complex both in vivo and the porcine ex-vivo model. Laser application produced clearly visible optical effects such as hyperreflectivity and tissue distortion in the treated retina. Tissue effects were even discernible in time-resolved OCT imaging when no hyper-reflectivity persisted after treatment. Data from ex-vivo porcine eyes showed similar to identical optical changes while effects visible in OCT appeared to correlate with applied pulse energy, leading to an additional reflective layer when lesions became visible in indirect ophthalmoscopy. Conclusions: Our results support the hypothesis that real-time high-resolution OCT may be a promising modality to obtain additional information about the extent of tissue damage caused by SRT treatment. Data shows that our exvivo porcine model adequately reproduces the effects occurring in-vivo, and thus can be used to further investigate this promising imaging technique.
Resumo:
BACKGROUND The copy number variation (CNV) in beta-defensin genes (DEFB) on human chromosome 8p23 has been proposed to contribute to the phenotypic differences in inflammatory diseases. However, determination of exact DEFB CN is a major challenge in association studies. Quantitative real-time PCR (qPCR), paralog ratio tests (PRT) and multiplex ligation-dependent probe amplification (MLPA) have been extensively used to determine DEFB CN in different laboratories, but inter-method inconsistencies were observed frequently. In this study we asked which one is superior among the three methods for DEFB CN determination. RESULTS We developed a clustering approach for MLPA and PRT to statistically correlate data from a single experiment. Then we compared qPCR, a newly designed PRT and MLPA for DEFB CN determination in 285 DNA samples. We found MLPA had the best convergence and clustering results of the raw data and the highest call rate. In addition, the concordance rates between MLPA or PRT and qPCR (32.12% and 37.99%, respectively) were unacceptably low with underestimated CN by qPCR. Concordance rate between MLPA and PRT (90.52%) was high but PRT systematically underestimated CN by one in a subset of samples. In these samples a sequence variant which caused complete PCR dropout of the respective DEFB cluster copies was found in one primer binding site of one of the targeted paralogous pseudogenes. CONCLUSION MLPA is superior to PRT and even more to qPCR for DEFB CN determination. Although the applied PRT provides in most cases reliable results, such a test is particularly sensitive to low-frequency sequence variations preferably accumulating in loci like pseudogenes which are most likely not under selective pressure. In the light of the superior performance of multiplex assays, the drawbacks of such single PRTs could be overcome by combining more test markers.
Resumo:
Performance on interval timing is often explained by the assumption of an internal clock based on neural counting. According to this account, a neural pacemaker generates pulses, and the number of pulses relating to a physical time interval is recorded by a counter. Thus, the number of accumulated pulses is the internal representation of this interval. Several studies demonstrated that large visual stimuli are perceived to last longer than smaller ones presented for the same duration. The present study was designed to investigate whether nontemporal visual stimulus size directly affects the internal clock. For this purpose, a temporal reproduction task was applied. Sixty participants were randomly assigned to one of two experimental conditions with stimulus size being experimentally varied within either the target or the reproduction interval. A direct effect of nontemporal stimulus size on the pacemaker-counter system should become evident irrespective of whether stimulus size was experimentally varied within the target or the reproduction interval. An effect of nontemporal stimulus size on reproduced duration only occurred when stimulus size was varied during the target interval. This finding clearly argues against the notion that nontemporal visual stimulus size directly affects the internal clock. Furthermore, our findings ruled out a decisional bias as a possible cause of the observed differential effect of stimulus size on reproduced duration. Rather the effect of stimulus size appeared to originate from the memory stage of temporal information processing at which the timing signal from the pacemaker-counter component is encoded in reference memory.